Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 98
Filter
1.
J Hum Nutr Diet ; 34(2): 273-285, 2021 04.
Article in English | MEDLINE | ID: mdl-33001515

ABSTRACT

BACKGROUND: Poor dietary intake increases disease risk, and poor sleep influences diet. This systematic review and meta-analysis of intervention studies aimed to evaluate the effect of sleep health on dietary intake in adults. METHODS: Five online databases were used to identify studies published between 1970 and 2019. Included studies were interventions that modified sleep and reported dietary outcomes. RESULTS: Fifty four full texts were assessed and 24 publications were included. Following risk of bias appraisal, data were narratively summarised and a sub-group of studies (n = 15) was meta-analysed to determine the effect of sleep on dietary intake. One intervention modified sleep timing and 23 modified duration. Sleep duration was partially restricted (≤5.5 h night-1 ) (n = 16), totally restricted (n = 4), partially and totally restricted (n = 1), and extended (n = 2). Dietary outcomes were energy intake (n = 24), carbohydrate, fat, protein intake (n = 20), single nutrient intake (n = 5), diet quality (n = 1) and food types (n = 1). Meta-analysis indicated partial sleep restriction results in higher energy intake in intervention compared with control [standardised mean difference (SMD) = 0.37; 95% confidence interval (CI) = 0.21-0.52; P < 0.001], with a mean difference of 204 kcal (95% CI = 112-295; P < 0.001) in daily energy intake, and a higher percentage of energy from fat, protein, carbohydrate (fat: SMD = 0.33; 95% CI = 0.16-0.51; P < 0.001; protein: SMD = 0.30, 95% CI = 0.12-0.47, P = 0.001; carbohydrate: SMD = 0.22, 95% CI = 0.04-0.39, P = 0.014). CONCLUSIONS: Partial sleep restriction with duration of ≤5.5 h day-1 increases daily energy intake, as well as fat, protein and carbohydrate intake. Further research is needed to determine the relationship between other dimensions of sleep health and dietary intake.


Subject(s)
Energy Intake , Sleep , Adult , Diet , Eating , Humans
2.
Bone Joint J ; 100-B(1): 20-27, 2018 01.
Article in English | MEDLINE | ID: mdl-29305446

ABSTRACT

AIMS: The aim of this study was to determine whether patients with metal-on-metal (MoM) arthroplasties of the hip have an increased risk of cardiac failure compared with those with alternative types of arthroplasties (non-MoM). PATIENTS AND METHODS: A linkage study between the National Joint Registry, Hospital Episodes Statistics and records of the Office for National Statistics on deaths was undertaken. Patients who underwent elective total hip arthroplasty between January 2003 and December 2014 with no past history of cardiac failure were included and stratified as having either a MoM (n = 53 529) or a non-MoM (n = 482 247) arthroplasty. The primary outcome measure was the time to an admission to hospital for cardiac failure or death. Analysis was carried out using data from all patients and from those matched by propensity score. RESULTS: The risk of cardiac failure was lower in the MoM cohort compared with the non-MoM cohort (adjusted hazard ratio (aHR) 0.901; 95% confidence interval (CI) 0.853 to 0.953). The risk of cardiac failure was similar following matching (aHR 0.909; 95% CI 0.838 to 0.987) and the findings were consistent in subgroup analysis. CONCLUSION: The risk of cardiac failure following total hip arthroplasty was not increased in those in whom MoM implants were used, compared with those in whom other types of prostheses were used, in the first seven years after surgery. Cite this article: Bone Joint J 2018;100-B:20-7.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Heart Failure/etiology , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/mortality , Female , Heart Failure/epidemiology , Hospitalization/statistics & numerical data , Humans , Male , Medical Record Linkage , Middle Aged , Prosthesis Design , Registries , Retrospective Studies , Risk Factors , United Kingdom/epidemiology
4.
Bone Joint J ; 100-B(1): 119-124, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29305460

ABSTRACT

AIMS: Tuberculosis (TB) infection of bones and joints accounts for 6.7% of TB cases in England, and is associated with significant morbidity and disability. Public Health England reports that patients with TB experience delays in diagnosis and treatment. Our aims were to determine the demographics, presentation and investigation of patients with a TB infection of bones and joints, to help doctors assessing potential cases and to identify avoidable delays. PATIENTS AND METHODS: This was a retrospective observational study of all adults with positive TB cultures on specimens taken at a tertiary orthopaedic centre between June 2012 and May 2014. A laboratory information system search identified the patients. The demographics, clinical presentation, radiology, histopathology and key clinical dates were obtained from medical records. RESULTS: A total of 31 adult patients were identified. Their median age was 37 years (interquartile range (IQR): 29 to 53); 21 (68%) were male; 89% were migrants. The main sites affected were joints (10, 32%), the spine (8, 26%) and long bones (6, 19%); 8 (26%) had multifocal disease. The most common presenting symptoms were pain (29/31, 94%) and swelling (26/28, 93%). 'Typical' symptoms of TB, such as fever, sweats and weight loss, were uncommon. Patients waited a median of seven months (IQR 3 to 13.5) between the onset of symptoms and referral to the tertiary centre and 2.3 months (IQR 1.6 to 3.4.)) between referral and starting treatment. Radiology suggested TB in 26 (84%), but in seven patients (23%) the initial biopsy specimens were not sent for mycobacterial culture, necessitating a second biopsy. Rapid Polymerase Chain Reaction-based testing for TB using Xpert MTB/RIF was performed in five patients; 4 (80%) tested positive for TB. These patients had a reduced time between the diagnostic biopsy and starting treatment than those whose samples were not tested (median eight days versus 36 days, p = 0.016). CONCLUSION: Patients with bone and joint TB experience delays in diagnosis and treatment, some of which are avoidable. Maintaining a high index of clinical suspicion and sending specimens for mycobacterial culture are crucial to avoid missing cases. Rapid diagnostic tests reduce delays and should be performed on patients with radiological features of TB. Cite this article: Bone Joint J 2018;100-B:119-24.


Subject(s)
Tuberculosis, Osteoarticular/diagnosis , Adult , Aged , Aged, 80 and over , Antitubercular Agents/administration & dosage , Biopsy , Critical Pathways , Delayed Diagnosis , Drug Administration Schedule , England/epidemiology , Female , Humans , Male , Middle Aged , Referral and Consultation/standards , Referral and Consultation/statistics & numerical data , Retrospective Studies , Time Factors , Tuberculosis, Osteoarticular/drug therapy , Tuberculosis, Osteoarticular/epidemiology , Tuberculosis, Osteoarticular/pathology
5.
J Biomed Mater Res B Appl Biomater ; 106(2): 632-638, 2018 02.
Article in English | MEDLINE | ID: mdl-28276193

ABSTRACT

Recently the use of dissimilar metals in spine instrumentation has increased, especially in the case of adult deformities, where rods made from Cobalt Chrome alloys (CoCr) are used with Titanium (Ti) screws. The use of dissimilar metals increases the risk of galvanic corrosion and patients have required revision spine surgery due to severe metallosis that may have been caused by corrosion. We aimed to assess the presence of corrosion in spine implant retrievals from constructs with two types of material combinations: similar (Ti/Ti) and dissimilar (CoCr/Ti). First, we devised a grading score for corrosion of the rod-fixture junctions. Then, we applied this score to a collection of retrieved spine implants. Our proposed corrosion grading score was proven reliable (kappa > 0.7). We found no significant difference in the scores between 4 CoCr and 11 Ti rods (p = 0.0642). There was no indication that time of implantation had an effect on the corrosion score (p = 0.9361). We recommend surgeons avoid using implants designs with dissimilar metals to reduce the risk of corrosion whilst a larger scale study of retrieved spine implants is conducted. Future studies can now use our scoring system for spine implant corrosion. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 632-638, 2018.


Subject(s)
Chromium Alloys/pharmacology , Device Removal , Prostheses and Implants/adverse effects , Spine/drug effects , Titanium/pharmacology , Adult , Cohort Studies , Corrosion , Female , Humans , Male , Pedicle Screws , Risk Factors , Spine/surgery , Time Factors
7.
Bone Joint Res ; 6(5): 345-350, 2017 May.
Article in English | MEDLINE | ID: mdl-28566326

ABSTRACT

OBJECTIVES: The use of ceramic femoral heads in total hip arthroplasty (THA) has increased due to their proven low bearing wear characteristics. Ceramic femoral heads are also thought to reduce wear and corrosion at the head-stem junction with titanium (Ti) stems when compared with metal heads. We sought to evaluate taper damage of ceramic compared with metal heads when paired with cobalt chromium (CoCr) alloy stems in a single stem design. METHODS: This retrieval study involved 48 total hip arthroplasties (THAs) with CoCr V40 trunnions paired with either CoCr (n = 21) or ceramic (n = 27) heads. The taper junction of all hips was evaluated for fretting/corrosion damage and volumetric material loss using a roundness-measuring machine. We used linear regression analysis to investigate taper damage differences after adjusting for potential confounding variables. RESULTS: We measured median taper material loss rates of 0.210 mm3/year (0.030 to 0.448) for the metal head group and 0.084 mm3/year (0.059 to 0.108) for the ceramic group. The difference was not significant (p = 0.58). Moreover, no significant correlation between material loss and implant or patient factors (p > 0.05) was found. CONCLUSIONS: Metal heads did not increase taper damage on CoCr trunnions compared with ceramic heads from the same hip design. The amount of material released at the taper junctions was very low when compared with available data regarding CoCr/Ti coupling in metal-on-metal bearings.Cite this article: A. Di Laura, H. Hothi, J. Henckel, I. Swiatkowska, M. H. L. Liow, Y-M. Kwon, J. A. Skinner, A. J. Hart. Retrieval analysis of metal and ceramic femoral heads on a single CoCr stem design. Bone Joint Res 2017;6:-350. DOI: 10.1302/2046-3758.65.BJR-2016-0325.R1.

8.
Knee ; 24(4): 808-815, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28442184

ABSTRACT

AIMS: Pigmented villonodular synovitis (PVNS) is a rare, locally aggressive and potentially recurrent synovial disease. We present the largest single-centre experience of knee PVNS. Our aim was to evaluate our tertiary hospital's experience in the management of knee PVNS. PATIENTS AND METHODS: Retrospective data collection of consecutive cases of knee PVNS from 2002 to 2015. RESULTS: In total, 214 cases of knee PVNS were identified which represented 53.4% of all PVNS (12.1% were recurrent at presentation). 100 were localised PVNS (LPVNS), 114 diffuse PVNS (DPVNS) and two malignant PVNS. Knee PVNS was more likely to occur in females with a mean age of 39. Following surgery, 47.6% had recurrence with DPVNS as opposed to 8.6% with LPVNS. In LPVNS, there was no significant difference in recurrence between open and arthroscopic synovectomy (8.7% vs 9.1%, P>0.05). However, in DPVNS, there was a significantly higher risk of recurrence with arthroscopic compared to open synovectomy (83.3% vs 44.8%, RR=1.86 95% CI 1.32-2.62, P=0.0004). CONCLUSION: PVNS can be difficult to treat. We found no difference in local recurrence rates between open and arthroscopic treatment of LPVNS but significantly increased rates of recurrence for DPVNS following arthroscopic treatment. We would therefore recommend open synovectomy for DPVNS.


Subject(s)
Arthroscopy/methods , Synovectomy/methods , Synovitis, Pigmented Villonodular/surgery , Adult , Aged , Arthroscopy/adverse effects , Female , Humans , Knee Joint/pathology , Knee Joint/surgery , Male , Middle Aged , Recurrence , Retrospective Studies , Synovectomy/adverse effects , Tertiary Care Centers , United Kingdom
9.
Bone Joint J ; 98-B(7): 917-24, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27365469

ABSTRACT

AIMS: Surgeons have commonly used modular femoral heads and stems from different manufacturers, although this is not recommended by orthopaedic companies due to the different manufacturing processes. We compared the rate of corrosion and rate of wear at the trunnion/head taper junction in two groups of retrieved hips; those with mixed manufacturers (MM) and those from the same manufacturer (SM). MATERIALS AND METHODS: We identified 151 retrieved hips with large-diameter cobalt-chromium heads; 51 of two designs that had been paired with stems from different manufacturers (MM) and 100 of seven designs paired with stems from the same manufacturer (SM). We determined the severity of corrosion with the Goldberg corrosion score and the volume of material loss at the head/stem junction. We used multivariable statistical analysis to determine if there was a significant difference between the two groups. RESULTS: We found no significant difference in the corrosion scores of the two groups. The median rate of material loss at the head/stem junction for the MM and SM groups were 0.39 mm(3)/year (0.00 to 4.73) and 0.46 mm(3)/year (0.00 to 6.71) respectively; this difference was not significant after controlling for confounding factors (p = 0.06). CONCLUSION: The use of stems with heads of another manufacturer does not appear to affect the amount of metal lost from the surfaces between these two components at total hip arthroplasty. Other surgical, implant and patient factors should be considered when determining the mechanisms of failure of large diameter metal-on-metal hip arthroplasties. Cite this article: Bone Joint J 2016;98-B:917-24.


Subject(s)
Arthroplasty, Replacement, Hip , Corrosion , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Prosthesis Design , Prosthesis Failure , Adult , Aged , Chromium , Chromium Alloys , Cobalt , Female , Humans , Male , Middle Aged , Titanium
11.
Bone Joint J ; 98-B(1): 33-9, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26733513

ABSTRACT

AIMS: The National Joint Registry for England, Wales and Northern Ireland (NJR) has extended its scope to report on hospital, surgeon and implant performance. Data linkage of the NJR to the London Implant Retrieval Centre (LIRC) has previously evaluated data quality for hip primary procedures, but did not assess revision records. METHODS: We analysed metal-on-metal hip revision procedures performed between 2003 and 2013. A total of 69 929 revision procedures from the NJR and 929 revised pairs of components from the LIRC were included. RESULTS: We were able to link 716 (77.1%) revision procedures on the NJR to the LIRC. This meant that 213 (22.9%) revision procedures at the LIRC could not be identified on the NJR. We found that 349 (37.6%) explants at the LIRC completed the full linkage process to both NJR primary and revision databases. Data completion was excellent (> 99.9%) for revision procedures reported to the NJR. DISCUSSION: This study has shown that only approximately one third of retrieved components at the LIRC, contributed to survival curves on the NJR. We recommend prospective registry-retrieval linkage as a tool to feedback missing and erroneous data to the NJR and improve data quality. TAKE HOME MESSAGE: Prospective Registry - retrieval linkage is a simple tool to evaluate and improve data quality on the NJR.


Subject(s)
Arthroplasty, Replacement, Hip/statistics & numerical data , Metal-on-Metal Joint Prostheses/statistics & numerical data , Reoperation/statistics & numerical data , Epidemiologic Methods , Humans , Information Storage and Retrieval , Informed Consent , Metal-on-Metal Joint Prostheses/standards , Prosthesis Design , Prosthesis Failure , United Kingdom
12.
Bone Joint J ; 97-B(1): 10-8, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25568407

ABSTRACT

Arthroplasty registries are important for the surveillance of joint replacements and the evaluation of outcome. Independent validation of registry data ensures high quality. The ability for orthopaedic implant retrieval centres to validate registry data is not known. We analysed data from the National Joint Registry for England, Wales and Northern Ireland (NJR) for primary metal-on-metal hip arthroplasties performed between 2003 and 2013. Records were linked to the London Implant Retrieval Centre (RC) for validation. A total of 67,045 procedures on the NJR and 782 revised pairs of components from the RC were included. We were able to link 476 procedures (60.9%) recorded with the RC to the NJR successfully. However, 306 procedures (39.1%) could not be linked. The outcome recorded by the NJR (as either revised, unrevised or death) for a primary procedure was incorrect in 79 linked cases (16.6%). The rate of registry-retrieval linkage and correct assignment of outcome code improved over time. The rates of error for component reference numbers on the NJR were as follows: femoral head category number 14/229 (5.0%); femoral head batch number 13/232 (5.3%); acetabular component category number 2/293 (0.7%) and acetabular component batch number 24/347 (6.5%). Registry-retrieval linkage provided a novel means for the validation of data, particularly for component fields. This study suggests that NJR reports may underestimate rates of revision for many types of metal-on-metal hip replacement. This is topical given the increasing scope for NJR data. We recommend a system for continuous independent evaluation of the quality and validity of NJR data.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/statistics & numerical data , Datasets as Topic/standards , Hip Prosthesis/statistics & numerical data , Osteoarthritis, Hip/surgery , Prosthesis Failure , Cohort Studies , England/epidemiology , Female , Humans , Incidence , London/epidemiology , Male , Metals , Northern Ireland/epidemiology , Osteoarthritis, Hip/epidemiology , Prognosis , Prosthesis Design , Registries , Reoperation/statistics & numerical data , Retrospective Studies , Risk Assessment , State Medicine , Treatment Outcome , Wales/epidemiology
13.
Indian J Orthop ; 49(6): 595-601, 2015.
Article in English | MEDLINE | ID: mdl-26806965

ABSTRACT

BACKGROUND: Hip resurfacing arthroplasty (HRA) is primarily indicated for young, active patients with disabling coxarthrosis who wish to remain active and return to sports after surgery. Relatively few prospective studies have assessed return to sporting activity and impact of gender and age on this. MATERIALS AND METHODS: Seventy-nine consecutive patients treated with HRA were included. Patients were reviewed clinically and radiologically. Function was assessed using the modified University of California Los Angeles (UCLA) activity score. The Oxford, Harris and WOMAC hip scores were calculated. RESULTS: Average age at the time of surgery was 54.9 years (range 34.5-73.6 years). Average preoperative and postoperative UCLA scores were 4 and 7.6 respectively. Patients were involved in 2 (0-4) sporting activities preoperatively and 2 (0-5) postoperatively. Preoperative and postoperative Oxford Hip Scores, Harris Hip Score and WOMAC scores were 40, 46 and 51 and 16, 94 and 3 respectively (P < 0.0001). Patients returned to sports at an average of 3 months postoperatively. CONCLUSION: Patients were able to return to sports by 3 months and perform the same number of activities at preoperative intensity. Activity levels are maintained up to the medium term with few complications.

14.
Clin Orthop Surg ; 6(4): 373-8, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25436059

ABSTRACT

BACKGROUND: Management of the patella during total knee arthroplasty (TKA) is controversial. Multiple studies have examined mechanical and clinical results of TKA with native and resurfaced patellae with no clear consensus. METHODS: We surveyed a large cohort of consultant surgeons in a questionnaire based study in order to assess the indications for patella resurfacing and to correlate practice with degree of specialization, experience and volume of procedures performed. RESULTS: Six hundred and nineteen surgeons were included. The main indication for patella resurfacing was patellofemoral arthritis. The ratio of those who always:sometimes:never resurfaced was 1:2:1 irrespective of experience or volume performed. There was no difference between knee specialists and non-specialists (p = 0.977) or between high and lower volume surgeons (p = 0.826). Senior and high volume surgeons tended to always resurface. CONCLUSIONS: The majority of surgeons only sometimes resurfaced the patella. The number who always and never resurfaced were similar. There was a tendency for more experienced and high volume surgeons to always resurface.


Subject(s)
Arthritis/surgery , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Orthopedics/statistics & numerical data , Patella/surgery , Arthroplasty, Replacement, Knee/statistics & numerical data , Cohort Studies , Humans , Patellofemoral Joint/surgery , Surveys and Questionnaires , United Kingdom/epidemiology
15.
Bone Joint J ; 96-B(10): 1392-5, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25274927

ABSTRACT

In patients with a tumour affecting the distal ulna it is difficult to preserve the function of the wrist following extensive local resection. We report the outcome of 12 patients (nine female, three male) who underwent excision of the distal ulna without local soft-tissue reconstruction. In six patients, an aggressive benign tumour was present and six had a malignant tumour. At a mean follow-up of 64 months (15 to 132) the mean Musculoskeletal Tumour score was 64% (40% to 93%) and the mean DASH score was 35 (10 to 80). The radiological appearances were satisfactory in most patients. Local recurrence occurred in one patient with benign disease and two with malignant disease. The functional outcome was thus satisfactory at a mean follow-up in excess of five years, with a relatively low rate of complications. The authors conclude that complex reconstructive soft-tissue procedures may not be needed in these patients.


Subject(s)
Bone Neoplasms/surgery , Orthopedic Procedures/methods , Sarcoma/surgery , Ulna/surgery , Adult , Aged , Biopsy , Bone Neoplasms/diagnosis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prostheses and Implants , Radiography , Plastic Surgery Procedures , Retrospective Studies , Sarcoma/diagnosis , Time Factors , Treatment Outcome , Ulna/diagnostic imaging , Ulna/pathology , Young Adult
16.
Bone Joint J ; 96-B(8): 1098-105, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25086127

ABSTRACT

The pre-operative differentiation between enchondroma, low-grade chondrosarcoma and high-grade chondrosarcoma remains a diagnostic challenge. We reviewed the accuracy and safety of the radiological grading of cartilaginous tumours through the assessment of, first, pre-operative radiological and post-operative histological agreement, and second the rate of recurrence in lesions confirmed as high-grade on histology. We performed a retrospective review of major long bone cartilaginous tumours managed by curettage as low grade between 2001 and 2012. A total of 53 patients with a mean age of 47.6 years (8 to 71) were included. There were 23 men and 30 women. The tumours involved the femur (n = 20), humerus (n = 18), tibia (n = 9), fibula (n = 3), radius (n = 2) and ulna (n = 1). Pre-operative diagnoses resulted from multidisciplinary consensus following radiological review alone for 35 tumours, or with the addition of pre-operative image guided needle biopsy for 18. The histologically confirmed diagnosis was enchondroma for two (3.7%), low-grade chondrosarcoma for 49 (92.6%) and high-grade chondrosarcoma for two (3.7%). Three patients with a low-grade tumour developed a local recurrence at a mean of 15 months (12 to 17) post-operatively. A single high-grade recurrence (grade II) was treated with tibial diaphyseal replacement. The overall recurrence rate was 7.5% at a mean follow-up of 4.7 years (1.2 to 12.3). Cartilaginous tumours identified as low-grade on pre-operative imaging with or without additional image-guided needle biopsy can safely be managed as low-grade without pre-operative histological diagnosis. A few tumours may demonstrate high-grade features histologically, but the rates of recurrence are not affected.


Subject(s)
Bone Neoplasms/surgery , Cartilage Diseases/surgery , Chondroma/surgery , Chondrosarcoma/surgery , Curettage/methods , Adolescent , Adult , Aged , Biopsy, Needle , Bone Neoplasms/diagnosis , Cartilage Diseases/diagnosis , Child , Chondroma/diagnosis , Chondrosarcoma/diagnosis , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Observer Variation , Preoperative Care/methods , Retrospective Studies , Treatment Outcome , Young Adult
17.
J Bone Joint Surg Am ; 96(13): 1091-1099, 2014 Jul 02.
Article in English | MEDLINE | ID: mdl-24990974

ABSTRACT

BACKGROUND: We designed a prospective, single-center study to assess whether blood metal ion levels could predict implant failure in patients managed with unilateral metal-on-metal hip resurfacing or total hip arthroplasty. METHODS: Five hundred and ninety-seven patients who had received unilateral Articular Surface Replacement prostheses at least twelve months earlier were recruited. Blood metal ion levels were compared between the group of patients with failed implants and the group with non-failed implants. Implant failure was defined as prostheses associated with revision, an intention to revise, or poor patient-reported hip function (Oxford Hip Score, <31 of 48). Specificity, sensitivity, area under the curve, positive and negative predictive values, and odds ratios were calculated. Logistic regression analysis was used to identify other risk factors for implant failure. RESULTS: Patients with failed arthroplasty had significantly higher blood cobalt and chromium ion levels than did patients with non-failed arthroplasty (p < 0.01). Blood cobalt ion levels were disproportionately raised in patients with failed total hip arthroplasty (8.2 µg/L) compared with patients with failed hip resurfacing (2.5 µg/L) (p = 0.018). Blood chromium ion levels were not significantly different in patients with failed total hip arthroplasty and failed hip resurfacing (p = 0.058). The maximum value of either metal ion had good discriminant ability to predict implant failure (area under the curve, 0.76). A 7-µg/L cutoff had a positive predictive value of 0.75 (95% confidence interval, 0.66 to 0.82) and a negative predictive value of 0.82 (95% confidence interval, 0.78 to 0.86). In patients managed with total hip arthroplasty, for each increase of 1 µg/L there was a 23% (p < 0.001) increase in the odds of them being in the failed group. For patients managed with hip resurfacing, the increase in odds was 5% (p < 0.001). CONCLUSIONS: Raised levels of blood metal ions were associated with failed metal-on-metal hip resurfacings and total hip arthroplasties. A threshold level of 7 µg/L had inadequate sensitivity to be used in isolation as a screening test for implant failure, but it provided nearly optimal misclassification rates. No level had a perfect positive predictive value, and so we discourage surgeons from performing revision surgery based on blood metal ion levels alone. Levels of cobalt ions were raised out of proportion to levels of chromium ions in failed total hip arthroplasty and may reflect a different mechanism for metal ion generation. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Chromium/blood , Cobalt/blood , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Ions/blood , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Prosthesis Failure , Risk Factors , Sensitivity and Specificity
18.
Case Rep Orthop ; 2014: 837954, 2014.
Article in English | MEDLINE | ID: mdl-24991441

ABSTRACT

Fracture of a modern ceramic head component in total hip replacement is an uncommon but catastrophic complication. Hence, the occurrence of a second ceramic head fracture in the same hip replacement of an individual represents a perishingly rare event. We present the case as a means of highlighting potential risk factors for ceramic head fracture and suggest possible management strategies in such cases.

19.
Bone Joint J ; 96-B(2): 263-9, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24493195

ABSTRACT

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years. The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial.


Subject(s)
Coated Materials, Biocompatible , Durapatite , Femoral Neoplasms/surgery , Forecasting , Prosthesis Implantation/methods , Adolescent , Adult , Bone Cements , Child , Child, Preschool , Female , Femoral Neoplasms/diagnostic imaging , Femoral Neoplasms/mortality , Follow-Up Studies , Humans , Male , Prosthesis Design , Radiography , Retrospective Studies , Survival Rate/trends , Treatment Outcome , United Kingdom/epidemiology , Young Adult
20.
Bone Joint J ; 96-B(1): 54-8, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24395311

ABSTRACT

The management of failed autologous chondrocyte implantation (ACI) and matrix-assisted autologous chondrocyte implantation (MACI) for the treatment of symptomatic osteochondral defects in the knee represents a major challenge. Patients are young, active and usually unsuitable for prosthetic replacement. This study reports the results in patients who underwent revision cartilage transplantation of their original ACI/MACI graft for clinical or graft-related failure. We assessed 22 patients (12 men and 10 women) with a mean age of 37.4 years (18 to 48) at a mean of 5.4 years (1.3 to 10.9). The mean period between primary and revision grafting was 46.1 months (7 to 89). The mean defect size was 446.6 mm(2) (150 to 875) and they were located on 11 medial and two lateral femoral condyles, eight patellae and one trochlea. The mean modified Cincinnati knee score improved from 40.5 (16 to 77) pre-operatively to 64.9 (8 to 94) at their most recent review (p < 0.001). The visual analogue pain score improved from 6.1 (3 to 9) to 4.7 (0 to 10) (p = 0.042). A total of 14 patients (63%) reported an 'excellent' (n = 6) or 'good' (n = 8) clinical outcome, 5 'fair' and one 'poor' outcome. Two patients underwent patellofemoral joint replacement. This study demonstrates that revision cartilage transplantation after primary ACI and MACI can yield acceptable functional results and continue to preserve the joint.


Subject(s)
Cartilage, Articular/surgery , Chondrocytes/transplantation , Chondromalacia Patellae/surgery , Knee Injuries/surgery , Osteochondritis Dissecans/surgery , Adolescent , Adult , Arthroscopy , Cartilage, Articular/injuries , Chronic Disease , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pain Measurement/methods , Reoperation/methods , Treatment Failure , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...