Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Feline Med Surg ; 11(10): 847-55, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19539512

ABSTRACT

Classification of pleural effusion (PE) is central to diagnosis. Traditional veterinary classification has distinguished between transudates, modified transudates and exudates. In human medicine PEs are divided into only two categories: transudates and exudates. The aim of this study was to evaluate, in 20 cats presented with PE, paired samples of serum and pleural fluid for the following parameters: Light's criteria (pleural fluid lactate dehydrogenase concentration (LDHp), pleural fluid/serum LDH ratio, pleural fluid/serum total protein ratio (TPr)), pleural fluid total protein, pleural fluid cholesterol concentration, pleural fluid/serum cholesterol ratio (CHOLr), serum-effusion cholesterol gradient (serum cholesterol minus PE cholesterol concentration (CHOLg)), PE total nucleated cells count (TNCCp) and pleural fluid glucose (GLUp). LDHp and TPr were found most reliable when distinguishing between transudates and exudates, with sensitivity of 100% and 91% and specificity of 100%, respectively. When conflict between the clinical picture and laboratory results exists, calculation of CHOLr, CHOLg and TNCCp measurement may help in the classification of the effusion. Measurement of serum albumin (in the case of a transudate) may provide additional information regarding the pathogenesis of the effusion.


Subject(s)
Cat Diseases/diagnosis , Exudates and Transudates , Pleural Effusion/veterinary , Animals , Blood Proteins/analysis , Cat Diseases/blood , Cats , Comorbidity , Lactate Dehydrogenases/analysis , Pleural Effusion/diagnosis , Prospective Studies , ROC Curve , United Kingdom
2.
J Feline Med Surg ; 7(3): 153-62, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15922222

ABSTRACT

A continuous glucose monitoring system (CGMS) was evaluated in 14 cats with naturally occurring diabetes mellitus. The device measures interstitial fluid glucose continuously, by means of a sensor placed in the subcutaneous tissue. All cats tolerated the device well and a trace was obtained on 15/16 occasions. There was good correlation between the CGMS values and blood glucose concentration measured using a glucometer (r=0.932, P<0.01). Limitations to the use of the CGMS are its working glucose range of 2.2-22.2 mmol/l (40-400 mg/dl) and the need for calibration with a blood glucose measurement at least every 12 h. When compared to a traditional blood glucose curve, the CGMS is minimally invasive, reduces the number of venepunctures necessary to assess the kinetics of insulin therapy in a patient and provides a truly continuous glucose curve.


Subject(s)
Blood Glucose Self-Monitoring/veterinary , Blood Glucose/metabolism , Cat Diseases/blood , Diabetes Mellitus/veterinary , Animals , Blood Glucose Self-Monitoring/methods , Calibration , Cats , Diabetes Mellitus/blood , Female , Male , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL