1.
Am J Infect Control ; 52(6): 635-643, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38408542

ABSTRACT

BACKGROUND: Outbreaks linked to inadequate endoscope drying have infected numerous patients, and current standards and guidelines recommend at least 10 minutes of forced air for drying channels. This study evaluated a new forced-air drying system (FADS) for endoscopes. METHODS: Drying was assessed using droplet detection cards; visual inspection of air/water connectors, suction connectors, and distal ends; and borescope examinations of endoscope interiors. Assessments were performed after automated endoscope reprocessor (AER) alcohol flush and air purge cycles and after 10-minute FADS cycles. RESULTS: Researchers evaluated drying during encounters with 22 gastroscopes and 20 colonoscopes. After default AER alcohol and air purge cycles, 100% (42/42) of endoscopes were still wet. Substantial fluid emerged from distal ends during the first 15 seconds of the FADS cycle, and droplets also emerged from air/water and suction connectors. Following FADS cycle completion, 100% (42/42) were dry, with no retained fluid detected by any of the assessment methods. CONCLUSIONS: Multiple endoscope ports and channels remained wet after AER cycles intended to aid in drying but were dry after the FADS cycle. This study reinforced the need to evaluate the effectiveness of current drying practices and illustrated the use of practical tools in a real-world setting.


Subject(s)
Endoscopes , Humans , Endoscopes/microbiology , Desiccation/methods , Disinfection/methods , Disinfection/standards , Equipment Contamination/prevention & control
2.
Biomed Instrum Technol ; 58(1): 25-33, 2024.
Article in English | MEDLINE | ID: mdl-38377297

ABSTRACT

Objective: Borescope examinations of endoscope channels are commonly described in literature, but no studies on surgical instrument lumen inspection have been published recently. Inadequately processed surgical instruments have been implicated in patient infections. This study assessed the utility of borescopes for inspecting surgical instruments. Methods: The study team inspected and photographed sterilized, patient-ready arthroscopic shaver handpieces and suction tips using a tablet camera and borescopes to characterize internal anatomy, defects found in lumens, and the impact of recleaning on debris or residues. Results: Ten suctions and eight shavers were inspected. All suctions had internal ridges and suction holes that were perpendicular to the lumen. All shavers had visible ridges, elbows, and lever mechanisms inside lumens. Of the 18 instruments, 16 (88%) had internal features that appeared rough or jagged and 17 (94%) had visible debris or discoloration in the lumens. Recleaning efforts generally were effective for suctions, but multiple rounds of recleaning with enhanced steps were less effective for shavers, which were replaced. Researchers documented retained soil and brush bristles in several new shavers despite following manufacturer instructions for cleaning and found visible damage and discoloration within five uses. Discussion: This study demonstrated the value of borescope examinations for surgical instrument lumens. Visual inspections identified anatomical features that could influence cleaning effectiveness and detected residual soil, discoloration, and debris in most instruments. The findings suggested that manufacturer cleaning instructions were insufficient and additional cleaning was not always effective. In response, the site's multidisciplinary team strengthened risk assessment protocols and enhanced their cleaning practices.


Subject(s)
Disinfection , Endoscopes , Humans , Pilot Projects , Surgical Instruments , Soil , Equipment Contamination/prevention & control
3.
Am J Infect Control ; 51(6): 624-632, 2023 06.
Article in English | MEDLINE | ID: mdl-36907359

ABSTRACT

BACKGROUND: Health care is shifting toward minimally invasive procedures requiring increasingly complex instruments and sophisticated processing technologies. Effective training methods are needed to ensure sterile processing professionals acquire and retain essential skills. This study aimed to develop and evaluate a new training model that supports mastery and retention of complex key skills. METHODS: The model was pilot-tested with training focused on visual inspection of endoscopes. Pre- and post-training tests were administered to enhance learning during a face-to-face workshop that interspersed lectures and hands-on practice, followed by structured homework, and an online booster session. Surveys assessed satisfaction and confidence levels. RESULTS: Mean test scores for nine certified sterile processing employees increased significantly following the workshop (41% vs 84%, P < .001). After the workshop, all trainees identified actionable visible defects on patient-ready endoscopes in their facilities. Test scores remained high after 2 months (90%), and trainees reported higher technical confidence and satisfaction levels after training. CONCLUSIONS: This study demonstrated effectiveness and clinical relevance of a new, evidence-based model for training sterile processing professionals that incorporated pretesting, lectures, hands-on practice, a training booster, and post-testing to enhance learning. This model may be applicable to other complex skills necessary for infection prevention and patient safety.


Subject(s)
Clinical Competence , Clinical Relevance , Humans , Pilot Projects , Surveys and Questionnaires
4.
Am J Infect Control ; 51(1): 2-10, 2023 01.
Article in English | MEDLINE | ID: mdl-36075293

ABSTRACT

INTRODUCTION: Infections have been linked to damaged or contaminated endoscopes with visible defects. Endoscope processing standards and guidelines state endoscopes should be visually inspected every time they are used. This study evaluated a new visual inspection program using magnification and borescopes in an endoscopy department that had not previously utilized these tools. METHODS: Site personnel were given visual inspection tools and training before systematically examining fully processed endoscopes twice during a 2-month period. A risk assessment protocol was used to determine whether endoscopes required recleaning, repair, or other action. Findings were documented using log sheets, photographs, and videotapes. RESULTS: Visible damage and residue or debris were observed in 100% of 25 endoscopes at both assessments, and 76% required repair. Defects at baseline included scratches (88%); channel shredding or peeling (80%); adhesive band disintegration (80%); residual soil or debris (white 84%; black 68%; brown 40%; yellow/green 36%; and orange/red 8%); retained fluid (52%); and dents (40%). Findings were similar at follow-up. DISCUSSION/CONCLUSIONS: Visual inspection with magnification and borescopes identified actionable defects that could interfere with processing effectiveness in 100% of endoscopes. Infection preventionists have a critical role to play in supporting processing personnel now that standards, guidelines, and manufacturer instructions recommend enhanced visual inspection of every endoscope, every time.


Subject(s)
Disinfection , Endoscopes , Humans , Disinfection/methods , Endoscopy , Equipment Contamination
5.
Am J Infect Control ; 50(11): 1200-1207, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36244924

ABSTRACT

BACKGROUND: Sterile processing personnel routinely decontaminate medical devices that are heavily soiled with blood, tissue, and secretions. Contamination may spread throughout processing areas, potentially exposing personnel and patient-ready devices, especially when there is insufficient separation between the dirty and clean areas. OBJECTIVE: This study aimed to identify activities that generate splash, determine how far droplets travel during manual cleaning, characterize the impact of practices on splash generation, and assess effectiveness of personal protective equipment (PPE) at preventing splash exposure to technicians and visitors in the decontamination unit. METHODS: Moisture-detection paper was affixed to PPE and environmental surfaces in a new processing department designed to optimize workflow and prevent cross-contamination. Droplet generation and dispersal were assessed during manual cleaning of a colonoscope and a transvaginal ultrasound probe. RESULTS: Splash was generated by most activities and droplets were detected up to 7.25 feet away. Transporting wet endoscopes dispersed droplets on a 15-foot path from the sink to the automated endoscope reprocessor. Extensive droplets were detected on PPE worn by technicians at the sink and observers 3-4 feet away. CONCLUSIONS: Manual cleaning of devices generated substantial splash, drenching technicians and the environment with droplets that traveled more than 7 feet. Engineering controls and better PPE are needed to reduce personnel exposure and risks associated with the potential dispersal of contaminated fluids throughout the facility.

7.
Urology ; 164: 25-32, 2022 06.
Article in English | MEDLINE | ID: mdl-35123986

ABSTRACT

Flexible ureteroscopes are essential devices, and reusable models require meticulous cleaning and sterilization between procedures. Reprocessing is complex, time-consuming, and difficult due to the instrument's small size, fragility, and internal channel. The Food and Drug Administration recently raised concerns about the effectiveness of ureteroscope reprocessing. Due to inadequate reprocessing and maintenance, contaminated and damaged ureteroscopes pose risks to patient safety. This review describes ureteroscope reprocessing methods and summarizes evidence on reprocessing effectiveness and documented outcomes associated with the use of damaged or inadequately cleaned and sterilized ureteroscopes.


Subject(s)
Equipment Reuse , Ureteroscopes , Equipment Design , Humans
8.
Am J Infect Control ; 50(2): 126-132, 2022 02.
Article in English | MEDLINE | ID: mdl-34865859

ABSTRACT

BACKGROUND: Personnel working in sterile processing or endoscope reprocessing departments are at high risk of exposure to tissue, blood, and patient fluids when decontaminating reusable medical instruments and equipment. The effectiveness of protective measures for reprocessing personnel has not yet been systematically evaluated in real-world settings. OBJECTIVE: This pilot project aimed to identify reprocessing activities that generate splashes, determine how far droplets can travel in decontamination areas, and assess personal protective equipment exposure during routine activities. METHODS: Moisture-detection paper was affixed to environmental surfaces and personal protective equipment in a sterile processing department. Droplet dispersal was assessed after personnel simulated performance of routine reprocessing tasks. RESULTS: Visible droplets were generated during every reprocessing activity except running the sonication sink. Droplets traveled at least 3 feet when filling a sink, brushing a ureteroscope, and using a power sprayer to rinse a basin. Some activities dispersed droplets up to 5 feet from the sink. Personal protective equipment was splashed during most activities and did not prevent skin exposure even when properly donned and doffed. CONCLUSION: This hypothesis-generating pilot project found that routine reprocessing activities generated substantial splashing, and currently recommended personal protective equipment did not adequately protect sterile processing personnel from exposure.


Subject(s)
Decontamination , Personal Protective Equipment , Endoscopes , Humans , Pilot Projects , Ureteroscopes