Klin Lab Diagn ; 66(4): 210-212, 2021 Apr 17.
Article in English | MEDLINE | ID: mdl-33878241

ABSTRACT

To study the diagnostic characteristics of test systems for detecting antibodies to SARS-Cov-2. We studied the diagnostic characteristics of two test systems for detecting antibodies to SARS-Cov-2, registered in the Russian Federation. The first test system is a kit for detecting total antibodies to SARS-Cov-2 using immunochemiluminescence analysis on the «Cobas e 411¼ analyzer («Roche Diagnostics¼, Germany). The second test system is a kit for detecting IgM and IgG to SARS-Cov-2 («Core Technology Co., Ltd¼, China) by immunochromatographic analysis. The biological material for the study was blood serum. We assessed: diagnostic sensitivity, diagnostic specificity, and predictive value of positive and negative results. In the test system for detecting total antibodies to SARS-CoV-2, using an IHLA, the diagnostic sensitivity and specificity were 100%; the predictive value of positive and negative results was 100%. In the test system for the detection of IgM and IgG to Sars-CoV-2, using IHA, diagnostic sensitivity for IgM and IgG were 100%; diagnostic specificity for IgM - 60%, for IgG - 72%; predictive value of a positive result for IgM - 60%, IgG - 68,18%; predictive value of negative results for IgM and IgG - 100%. The best diagnostic characteristics were found in the test system for the detection of total antibodies to SARS-Cov-2, which must be taken into account when deciding whether to purchase test systems for the detection of antibodies to SARS-Cov-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Humans , Immunoglobulin G , Immunoglobulin M , Russia , Sensitivity and Specificity , Serologic Tests
2.
Klin Lab Diagn ; 65(10): 607-610, 2020 Sep 17.
Article in English | MEDLINE | ID: mdl-33245649

ABSTRACT

Comparative analysis of the impact of blood collection systems on the results of routine coagulation tests. The aim of this study was to conduct comparative analysis of the effects of blood collection systems on the results of routine coagulation tests. The study involved practically healthy women over 18 years of age female (n=30). Inclusion criteria: practically healthy individuals. Exclusion criteria: taking non-steroidal anti-inflammatory drugs, or oral contraceptives. Blood collection was carried out in the following systems: 1 system-Vacuette Premium,2 system- Improvacuter, 3 system- BD Vacutainer® Plus. Before and after centrifugation, visual assessment of tubes was performed.No signs for the presence of clots, hemolysis, or insufficient filling was observed. In each sample we measured prothrombin time (PV, sec), activated partial thromboplastin time (APTT, sec), and fibrinogen (F, g/l) by clotting method on the automatic coagulometer «Sta Compact¼ («Diagnostica Stago¼, France). The results of laboratory analyses were processed using parametric and non - parametric statistics using The Statistica 12.0 software. At the preanalytical laboratory stage, there were no differences when using systems for blood sampling: the clots and hemolysis were not detected in the samples, the level of filling of the sistems was sufficient. Comparative analysis revealed small, though statistically significant, differences for: PT when comparing Improvacuter wiht Vacuette Premium or BD Vacutainer®; APPT when comparing Improvacuter wiht Vacuette Premium. No differences were observed for Fg levels. Our results support the data available in the literature on the effects of blood-taking systems on hemostasis , which should be taken into account when purchasing blood collection systems.


Subject(s)
Blood Coagulation , Hemostasis , Adolescent , Adult , Blood Coagulation Tests , Female , Humans , Partial Thromboplastin Time , Prothrombin Time