1.
Int J Mol Sci ; 24(10)2023 May 15.
Article in English | MEDLINE | ID: mdl-37240114

ABSTRACT

We compared two de-escalation strategies guided by either extravascular lung water or global end-diastolic volume-oriented algorithms in patients with sepsis and ARDS. Sixty patients with sepsis and ARDS were randomized to receive de-escalation fluid therapy, guided either by the extravascular lung water index (EVLWI, n = 30) or the global end-diastolic volume index (GEDVI, n = 30). In cases of GEDVI > 650 mL/m2 or EVLWI > 10 mL/kg, diuretics and/or controlled ultrafiltration were administered to achieve the cumulative 48-h fluid balance in the range of 0 to -3000 mL. During 48 h of goal-directed de-escalation therapy, we observed a decrease in the SOFA score (p < 0.05). Extravascular lung water decreased only in the EVLWI-oriented group (p < 0.001). In parallel, PaO2/FiO2 increased by 30% in the EVLWI group and by 15% in the GEDVI group (p < 0.05). The patients with direct ARDS demonstrated better responses to dehydration therapy concerning arterial oxygenation and lung fluid balance. In sepsis-induced ARDS, both fluid management strategies, based either on GEDVI or EVLWI, improved arterial oxygenation and attenuated organ dysfunction. The de-escalation therapy was more efficient for direct ARDS.


Subject(s)
Respiratory Distress Syndrome , Sepsis , Humans , Lung , Sepsis/complications , Sepsis/therapy , Extravascular Lung Water , Fluid Therapy , Respiratory Distress Syndrome/therapy
2.
Turk J Anaesthesiol Reanim ; 50(1): 59-64, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35256347

ABSTRACT

OBJECTIVE: This study aimed to assess the predictive value of invasive and non-invasive dynamic parameters for evaluation of fluid responsiveness after off-pump coronary artery bypass grafting. METHODS: Thirty-two adult patients after off-pump coronary surgery were enrolled into a single-center pilot prospective observational study. After arrival to the intensive care unit, all patients received standard fluid challenge test to assess fluid responsiveness. The patients with an increase in cardiac index ≥ 15% after the test were defined as fluid responders. We measured pulse pressure variation using 2 monitoring systems (PPVPiCCO and PPVNK), stroke volume variation, heart-lung interaction index, and plethysmogram variability index before and after standard fluid challenge test. RESULTS: After intensive care unit admission, the absolute values of stroke volume variation, PPVPiCCO, PPVNK, and heart-lung interaction index were significantly higher among fluid responders (P < .05). Response to standard fluid challenge test was predicted by dynamic assessment of PPVPiCCO (area under the curve 0.84), PPVNK (area under the curve 0.71), stroke volume variation (area under the curve 0.77), and heart-lung interaction index (area under the curve 0.77) (P < .05). The plethysmogram variability index value did not demonstrate any predictive ability regarding fluid responsiveness (area under the curve 0.5, P =.1). CONCLUSIONS: In patients after off-pump coronary surgery, both invasive parameters such as pulse pressure and stroke volume variations and non-invasive parameter such as heart-lung interaction index are able to predict fluid responsiveness. Thus, these dynamic parameters can be used to guide fluid therapy during the early postoperative period after off-pump coronary surgery.

3.
J Cardiothorac Vasc Anesth ; 34(4): 926-931, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31677921

ABSTRACT

OBJECTIVE: To test the hypothesis that a positive end-expiratory pressure test and the mini-fluid challenge predict fluid responsiveness in patients after off-pump coronary artery bypass grafting. DESIGN: Single-center pilot prospective observational study. SETTING: City Hospital #1 of Arkhangelsk, Russian Federation. PARTICIPANTS: Thirty-two adult patients after off-pump coronary artery surgery. INTERVENTIONS: To assess fluid responsiveness, after arrival to the intensive care unit, all patients received a test with increase in positive end-expiratory pressure from 5 to 20 cmH2O for 2 minutes, a mini-fluid challenge test with administration of crystalloids at 1.5 mL/kg during 2 minutes, and standard fluid challenge test using 7 mL/kg during 10 minutes. MEASUREMENTS AND MAIN RESULTS: The patients with an increase in cardiac index by ≥15% after a standard fluid challenge test were defined as fluid responders. According to receiver operating characteristic analysis, a decrease in mean arterial pressure exceeding 5 mmHg in 120 seconds of the positive end-expiratory pressure test identified fluid responsiveness with an area under the curve of 0.73 (p = 0.03). The reduction in pulse pressure and stroke volume variations by more than 2% during mini-fluid challenge test predicted positive response to fluid load with an area under the curve of 0.77 and 0.75, respectively (p < 0.05). CONCLUSION: Both the positive end-expiratory pressure test and the mini-fluid challenge test are feasible after off-pump coronary artery bypass grafting and can be used to predict fluid responsiveness in these patients.


Subject(s)
Coronary Artery Bypass, Off-Pump , Fluid Therapy , Adult , Blood Pressure , Crystalloid Solutions , Hemodynamics , Humans , ROC Curve , Russia , Stroke Volume
4.
Front Med (Lausanne) ; 4: 132, 2017.
Article in English | MEDLINE | ID: mdl-28848733

ABSTRACT

BACKGROUND: The early warning scores may increase the safety of perioperative period. The objective of this study was to assess the diagnostic and predictive role of Integrated Pulmonary Index (IPI) after off-pump coronary artery bypass grafting (OPCAB). MATERIALS AND METHODS: Forty adult patients undergoing elective OPCAB were enrolled into a single-center prospective observational study. We assessed respiratory function using IPI that includes oxygen saturation, end-tidal CO2, respiratory rate, and pulse rate. In addition, we evaluated blood gas analyses and hemodynamics, including ECG, invasive arterial pressure, and cardiac index. The measurements were performed after transfer to the intensive care unit, after spontaneous breathing trial and at 2, 6, 12, and 18 h after extubation. RESULTS AND DISCUSSION: The value of IPI registered during respiratory support correlated weakly with cardiac index (rho = 0.4; p = 0.04) and ScvO2 (rho = 0.4, p = 0.02). After extubation, IPI values decreased significantly, achieving a minimum by 18 h. The IPI value ≤9 at 6 h after extubation was a predictor of complicated early postoperative period (AUC = 0.71; p = 0.04) observed in 13 patients. CONCLUSION: In off-pump coronary surgery, the IPI decreases significantly after tracheal extubation and may predict postoperative complications.

5.
Front Med (Lausanne) ; 4: 31, 2017.
Article in English | MEDLINE | ID: mdl-28377920

ABSTRACT

BACKGROUND: The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. MATERIALS AND METHODS: Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning (n = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning (n = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. RESULTS AND DISCUSSION: Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group (p < 0.01). The average time until tracheal extubation did not differ in the automated weaning and the protocolized weaning groups: 193 (115-309) and 197 (158-253) min, respectively, but increased to 290 (210-411) min in the standard weaning group. CONCLUSION: The automated weaning system after off-pump coronary surgery might provide postoperative ventilation in a more protective way, reduces the workload on medical staff, and does not prolong the duration of weaning from ventilator. The use of automated or protocolized weaning can reduce the duration of postoperative mechanical ventilation in comparison with non-protocolized weaning based on the physician's decision.