Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Surg ; 19(1): 47, 2019 May 02.
Article in English | MEDLINE | ID: mdl-31046730

ABSTRACT

BACKGROUND: This clinical trial evaluated the performance of a newly released fast-absorbable braided synthetic suture (Novosyn® Quick) in adults and paediatric patients undergoing elective skin closures. METHODS: This was a prospective international multicentre observational study. Two centres enrolled 100 patients, of which 50 were adults (visceral surgery, France) and 50 were paediatric patients (paediatric surgery, Germany). Surgeons used a 5-point Likert scale to assess handling characteristics of the suture. Patients and professionals used the Patient-Observer-Scar-Assessment-Scale (POSAS) to rate scar quality. Adverse events were monitored until 3 months postoperatively. RESULTS: Handling characteristics of Novosyn® Quick were in median rated very good by both general surgeons and paediatric surgeons. Patient components of POSAS (six questions; ten-level Likert scale; best possible score six) scored in median (range) 8.5 (6-28) in the paediatric group versus 12 (6-38) in the adult group, P = 0.01. Patients` overall opinions of POSAS were similar in both groups [mean (SD), 1.86 (0.99) in the paediatric group versus 2.08 (1.35) in the adult group, P = 0.3536]. Observer component of POSAS (six parameters; ten-level numeric rating scale, best possible score six) scored comparably in both groups [median (range), 8 (6-29) in the paediatric group versus 10 (6-28) in the adult group, P = 0.1403]. Observers overall opinion of POSAS favoured the paediatric patients group [mean (SD), 1.48 (0.61) versus 1.92 (1.06) in the adult group, P = 0.0131]. Adverse events in relation to wound healing were not observed in both patient groups. CONCLUSIONS: Our findings indicate, that Novosyn® Quick is safe and reliable for skin closure in adults and paediatric patients and can be regarded as a viable alternative to Vicryl® Rapide. TRIAL REGISTRATION: This trial was registered prospectively with ClinicalTrials.gov under the registration number NCT02680886 on 5 February 2016. The trial was approved by the Institutional Review Boards of both study locations (France: CCTIRS N° 16-103 and CNIL:MMS/CWR/AR163920; Germany: 398/15).


Subject(s)
Biocompatible Materials , Polylactic Acid-Polyglycolic Acid Copolymer , Suture Techniques , Sutures , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Cicatrix/prevention & control , Female , Germany , Humans , Infant , Male , Middle Aged , Prospective Studies , Suture Techniques/adverse effects , Suture Techniques/instrumentation , Sutures/adverse effects , Wound Healing
SELECTION OF CITATIONS
SEARCH DETAIL
...