Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 84(11): 113706, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24289403

ABSTRACT

There are many atomic force microscopy (AFM) applications that rely on quantifying the force between the AFM cantilever tip and the sample. The AFM does not explicitly measure force, however, so in such cases knowledge of the cantilever stiffness is required. In most cases, the forces of interest are very small, thus compliant cantilevers are used. A number of methods have been developed that are well suited to measuring low stiffness values. However, in some cases a cantilever with much greater stiffness is required. Thus, a direct, traceable method for calibrating very stiff (approximately 200 N/m) cantilevers is presented here. The method uses an instrumented and calibrated nanoindenter to determine the stiffness of a reference cantilever. This reference cantilever is then used to measure the stiffness of a number of AFM test cantilevers. This method is shown to have much smaller uncertainty than previously proposed methods. An example application to fracture testing of nanoscale silicon beam specimens is included.

2.
Biomaterials ; 25(19): 4615-26, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15120507

ABSTRACT

Self-hardening calcium phosphate cement (CPC) sets to form hydroxyapatite with high osteoconductivity, but its brittleness and low strength limit its use to only non-stress bearing locations. Previous studies developed bioactive composites containing hydroxyapatite fillers in Bis-GMA-based composites for bone repair applications, and they possessed higher strength values. However, these strengths were still lower than the strength of cortical bone. The aim of this study was to develop strong and bioactive composites by combining CPC fillers with nano-silica-fused whiskers in a resin matrix, and to characterize the mechanical properties and cell response. Silica particles were fused to silicon carbide whiskers to roughen the whisker surfaces for enhanced retention in the matrix. Mass ratios of whisker:CPC of 1:2, 1:1 and 2:1 were incorporated into a Bis-GMA-based resin and hardened by two-part chemical curing. Composite with only CPC fillers without whiskers served as a control. The specimens were tested using three-point flexure and nano-indentation. Composites with whisker:CPC ratios of 2:1 and 1:1 had flexural strengths (mean+/-SD; n=9) of (164+/-14) MPa and (139+/-22) MPa, respectively, nearly 3 times higher than (54+/-5) MPa of the control containing only CPC fillers (p<0.05). The strength of the new whisker-CPC composites was 3 times higher than the strength achieved in previous studies for conventional bioactive composites containing hydroxyapatite particles in Bis-GMA-based resins. The mechanical properties of the CPC-whisker composites nearly matched those of cortical bone and trabecular bone. Osteoblast-like cell adhesion, proliferation and viability were equivalent on the non-whisker control containing only CPC fillers, on the whisker composite at whisker:CPC of 1:1, and on the tissue culture polystyrene control, suggesting that the new CPC-whisker composite was non-cytotoxic.


Subject(s)
Calcium Phosphates/chemistry , Dental Cements/chemistry , Nanotubes/chemistry , Nanotubes/ultrastructure , Silicon Dioxide/chemistry , 3T3 Cells , Animals , Biocompatible Materials/chemistry , Bone Cements/chemistry , Bone Regeneration/physiology , Cell Survival , Elasticity , Hardness , Manufactured Materials/analysis , Materials Testing , Mice , Osseointegration/physiology , Tensile Strength
3.
Dent Mater ; 19(5): 359-67, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12742430

ABSTRACT

OBJECTIVE: Whiskers were recently used to reinforce dental composites to extend their use to large stress-bearing restorations. The aim of this study was to investigate the effects of different types of whiskers on composite properties. METHODS: Silicon nitride and silicon carbide whiskers were each mixed with silica particles at whisker/silica mass ratios of 0:1, 1:5, 1:2, 1:1, 2:1, 5:1, and 1:0, and thermally treated. The composite was heat-cured at 140 degrees C. Strength and fracture toughness were measured in flexure, while elastic modulus and hardness were measured with nano-indentation. RESULTS: Both whisker type and whisker/silica ratio had significant effects on composite properties (two-way ANOVA; p<0.001). Silicon nitride whiskers increased the composite strength and toughness more than did silicon carbide. Silicon carbide whiskers increased the modulus and hardness more than silicon nitride did. The silicon nitride whisker composite reached a strength (mean+/-SD; n=6) of 246+/-33 MPa at whisker/silica of 1:1, while the silicon carbide whisker composite reached 210+/-14 MPa at 5:1. Both were significantly higher than 114+/-18 MPa of a prosthetic control and 109+/-23 MPa of an inlay/onlay control (Tukey's multiple comparison test; family confidence coefficient=0.95). Fracture toughness and work-of-fracture were also increased by a factor of two. Higher whisker/silica ratio reduced the composite brittleness to 1/3 that of the inlay/onlay control. SIGNIFICANCE: Whisker type and whisker/silica ratio are key microstructural parameters that determine the composite properties. Reinforcement with silica-fused whiskers results in novel dental composites that possess substantially higher strength and fracture toughness, and lower brittleness than the non-whisker control composites.


Subject(s)
Composite Resins/chemistry , Analysis of Variance , Carbon Compounds, Inorganic , Dental Stress Analysis , Elasticity , Hardness , Inlays , Materials Testing , Microscopy, Electron, Scanning , Silicon Compounds
4.
Biomaterials ; 23(3): 735-42, 2002 Feb.
Article in English | MEDLINE | ID: mdl-11774848

ABSTRACT

Dental resin composites need to be strengthened in order to improve their performance in large stress-bearing applications such as crowns and multiple-unit restorations. Recently, silica-fused ceramic whiskers were used to reinforce dental composites, and the whisker-to-silica ratio was found to be a key microstructural parameter that determined the composite strength. The aim of this study was to further investigate the effects of whisker-to-silica ratio on the fracture toughness, elastic modulus, hardness and brittleness of the composite. Silica particles and silicon carbide whiskers were mixed at whisker:silica mass ratios of 0:1, 1:5. 1:2, 1:1, 2:1, 5:1, and 1:0. Each mixture was thermally fused, silanized and combined with a dental resin at a filler mass percentage of 60%. Fracture toughness was measured with a single-edge notched beam method. Elastic modulus and hardness were measured with a nano-indentation system. Whisker:silica ratio had significant effects on composite properties. The composite toughness (mean+/-SD; n = 9) at whisker:silica = 2:1 was (2.47+/-0.28) MPa m(1/2), significantly higher than (1.02+/-0.23) at whisker:silica = 0:1, (1.13+/-0.19) of a prosthetic composite control, and (0.95+/-0.11) of an inlay/onlay composite control (Tukey's at family confidence coefficient = 0.95). Elastic modulus increased monotonically and hardness plateaued with increasing the whisker:silica ratio. Increasing the whisker:silica ratio also decreased the composite brittleness, which became about 1/3 of that of the inlay:onlay control. Electron microscopy revealed relatively flat fracture surfaces for the controls, but much rougher ones for the whisker composites, with fracture steps and whisker pullout contributing to toughness. The whiskers appeared to be well-bonded with the matrix, probably due to the fused silica producing rough whisker surfaces. Reinforcement with silica-fused whiskers resulted in novel dental composites that possessed fracture toughness two times higher than, and brittleness less than half of current dental composites.


Subject(s)
Composite Resins/chemistry , Carbon Compounds, Inorganic/chemistry , Dental Restoration, Permanent , Elasticity , Materials Testing , Microscopy, Electron, Scanning , Silicon Compounds/chemistry , Silicon Dioxide/chemistry , Surface Properties
5.
J Mater Sci Mater Med ; 13(9): 875-83, 2002 Sep.
Article in English | MEDLINE | ID: mdl-15348553

ABSTRACT

The mechanical properties of dental resin composites need to be improved in order to extend their use to high stress-bearing applications such as crown and bridge restorations. Recent studies used single crystal ceramic whiskers to reinforce dental composites. The aim of this study was to investigate the effects of thermal cycling on whisker-reinforced composites. It was hypothesized that the whisker composites would not show a reduction in mechanical properties or the breakdown of whisker-resin interface after thermal cycling. Silicon carbide whiskers were mixed with silica particles, thermally fused, then silanized and incorporated into resin to make flexural specimens. The filler mass fraction ranged from 0% to 70%. The specimens were thermal cycled in 5 degrees C and 60 degrees C water baths, and then fractured in three-point bending to measure strength. Nano-indentation was used to measure modulus and hardness. No significant loss in composite strength, modulus and hardness was found after 10(5) thermal cycles (family confidence coefficient=0.95; Tukey's multiple comparison test). The strength of whisker composite increased with filler level up to 60%, then plateaued when filler level was further increased to 70%; the modulus and hardness increased monotonically with filler level. The strength and modulus of whisker composite at 70% filler level were significantly higher than the non-whisker controls both before and after thermal cycling. SEM revealed no separation at the whisker-matrix interfaces, and observed resin remnants on the pulled-out whiskers, indicating strong whisker-resin bonding even after 10(5) thermal cycles. In conclusion, novel dental resin composites containing silica-fused whiskers possessed superior strength and modulus compared to non-whisker composites both before and after thermal cycling. The whisker-resin bonding appeared to be resistant to thermal cycling in water, so that no loss in composite strength or stiffness occurred after prolonged thermal cycling.

SELECTION OF CITATIONS
SEARCH DETAIL
...