Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Endod ; 2023 Aug 07.
Article in English | MEDLINE | ID: mdl-37558177

ABSTRACT

INTRODUCTION: A combination labial infiltration (1.8 mL) plus lingual infiltration (1.8 mL) of 4% articaine with 1:100,000 epinephrine in the mandibular lateral incisor was found superior to a labial infiltration of 1.8 mL of the same solution. However, it is not known whether the volume or the location had the greatest effect. Therefore, the purpose of this prospective, randomized crossover study was to determine the anesthetic efficacy of a labial infiltration of a 3.6 mL volume of 4% articaine with 1:100,000 epinephrine compared with labial infiltration (1.8 mL) plus lingual infiltration (1.8 mL) of 4% articaine with 1:100,000 epinephrine in the mandibular lateral incisor. METHODS: One hundred subjects randomly received 2 sets of injections, using 4% articaine with 1:100,000 epinephrine, consisting of labial and lingual infiltrations of 1.8 mL (3.6 mL total) and 2 labial infiltrations of 1.8 mL (3.6 mL total) of the mandibular lateral incisor in 2 separate appointments. Electric pulp testing was used to determine anesthetic success (highest 80/80 reading). The data were analyzed statistically. RESULTS: The labial and lingual combination exhibited a significantly higher anesthetic success rate (97%) when compared with the 2 labial infiltrations (74%) and had significantly higher 80/80s readings from 1 minute to 58 minutes. CONCLUSIONS: Within the limitations of this clinical study, a combination labial plus lingual infiltration using a 3.6-mL volume of 4% articaine with 1:100,000 epinephrine significantly increased pulpal anesthetic success for the mandibular lateral incisor when compared with a labial infiltration using a 3.6-mL volume of articaine. Therefore, location of the infiltrations was more important than volume.

2.
J Emerg Med ; 37(3): 287-9, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19097729

ABSTRACT

BACKGROUND: Penile constriction devices are used for the enhancement of sexual performance. These devices have the potential to become incarcerated, leading to necrosis and amputation if not removed promptly. OBJECTIVE: This article presents a step-by-step approach for the safe removal of a hardened steel penile constriction device using somewhat unorthodox tools found in a hospital. CASE REPORT: We present a case of an incarcerated hardened steel penile constriction ring that was not able to be removed with conventional techniques. We describe a novel technique using an electric grinder and laryngoscope blade. CONCLUSION: The technique described in this article is a valuable and relatively safe technique for the Emergency Physician to facilitate the timely removal of a hardened steel constriction device.


Subject(s)
Device Removal/instrumentation , Penis/injuries , Adult , Constriction , Device Removal/methods , Emergency Service, Hospital , Humans , Male , Sexual Behavior , Steel
SELECTION OF CITATIONS
SEARCH DETAIL
...