Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 101: 79-86, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35985102

ABSTRACT

The track structure of the signal measured by the semiconductor pixel detector Timepix3 was modelled in the Monte Carlo MCNP® code. A detailed model at the pixel-level (256 × 256 pixels, 55 × 55 µm2 pixel size) was developed and used to generate and store clusters of adjacent hit pixels observed in the measured data because of particle energy deposition path, charge sharing, and drift processes. An analytical model of charge sharing effect and the detector energy resolution was applied to the simulated data. The method will help the user sort the measured clusters and distinguish radiation components of mixed fields by determining the response of Timepix3 detector to particular particle types, energies, and incidence angles that cannot be measured separately.

2.
Appl Radiat Isot ; 134: 351-357, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28899615

ABSTRACT

Decommissioning of nuclear facilities incurs high costs regarding the accurate characterisation and correct disposal of the decommissioned materials. Therefore, there is a need for the implementation of new and traceable measurement technologies to select the appropriate release or disposal route of radioactive wastes. This paper addresses some of the innovative outcomes of the project "Metrology for Decommissioning Nuclear Facilities" related to mapping of contamination inside nuclear facilities, waste clearance measurement, Raman distributed temperature sensing for long term repository integrity monitoring and validation of radiochemical procedures.

3.
Radiat Prot Dosimetry ; 163(3): 373-80, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24925899

ABSTRACT

Spectral fluences of neutrons generated in the heads of the radiotherapeutic linacs Varian Clinac 2100 C/D and Siemens ARTISTE were measured by means of the Bonner spheres spectrometer whose active detector of thermal neutrons was replaced by an activation detector, i.e. a tablet made of pure manganese. Measurements with different collimator settings reveal an interesting dependence of neutron fluence on the area defined by the collimator jaws. The determined neutron spectral fluences were used to derive ambient dose equivalent rate along the treatment coach. To clarify at which components of the linac neutrons are mainly created, the measurements were complemented with MCNPX calculations based on a realistic model of the Varian Clinac.


Subject(s)
Models, Statistical , Neutrons , Particle Accelerators/instrumentation , Radiometry/instrumentation , Radiometry/methods , Radiosurgery/instrumentation , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Monte Carlo Method , Radiation Dosage , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...