Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
Radiother Oncol ; 190: 109958, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37871751

ABSTRACT

Proton radiotherapy offers a dosimetric advantage compared to photon therapy in sparing normal tissue, but the clinical evidence for toxicity reductions in the treatment of head and neck cancer is limited. The Danish Head and Neck Cancer Group (DAHANCA) has initiated the DAHANCA 35 randomised trial to clarify the value of proton therapy (NCT04607694). The DAHANCA 35 trial is performed in an enriched population of patients selected by an anticipated benefit of proton therapy to reduce the risk of late dysphagia or xerostomia based on normal tissue complication probability (NTCP) modelling. We present our considerations on the trial design and a test of the selection procedure conducted before initiating the randomised study.


Subject(s)
Head and Neck Neoplasms , Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Protons , Head and Neck Neoplasms/radiotherapy , Proton Therapy/methods , Photons/therapeutic use , Probability , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted , Radiotherapy Dosage
2.
Int J Radiat Oncol Biol Phys ; 49(5): 1409-18, 2001 Apr 01.
Article in English | MEDLINE | ID: mdl-11286849

ABSTRACT

PURPOSE: To guarantee an accurate dose delivery, within +/- 2.5%, in a Phase III randomized trial of prostate cancer irradiation (68 vs. 78 Gy) by means of a comprehensive in vivo dosimetry program. METHODS AND MATERIALS: Prostate patients are generally treated in our clinic with a 3-field isocentric technique: an 8-MV anteroposterior beam and 2 18-MV wedged laterals. All fields are shaped conformally to the PTV. Patients were randomized between two dose levels of 68 Gy and 78 Gy. During treatment, the entrance and exit dose were measured for each patient with diodes. Special 2.5-mm thick steel build-up caps were applied to make the diodes appropriate for measurements in 18-MV photon beams as well. Portal images were used to verify the correct position of the diodes and to detect and correct for gas filling in the rectum that may influence the exit dose reading. Entrance and exit dose measurements were converted to midplane dose, which was used in combination with a depth dose correction to obtain the dose at the specification point. An action level of 2.5% was applied. RESULTS: The added build-up for the diodes in the 18-MV beams resulted in correction factors that were only slightly sensitive to changes in beam setup and comparable to the corrections used in the 8-MV beams for diodes without extra build-up. The calibration factor increased almost linearly with cumulative dose: 0.7%/kGy for the 8-MV and 1.2%/kGy for the 18-MV photon beams. The introduction of average correction factors made the analysis easier, while keeping the accuracy within acceptable limits. In a period of 3 years, 225 patients were analyzed, from which 8 patients needed to be corrected. The average ratio of measured and prescribed dose was 1.009 (standard deviation [SD] 0.012) for the total group treated on two linear accelerators. When the results were analyzed per accelerator, the ratios were 1.002 (SD, 0.001) for Accelerator A and 1.015 (SD, 0.001) for Accelerator B. This difference could be attributed to the cumulative effect of three small imperfections in the performance of Accelerator B that were well within the limits of our quality assurance program. CONCLUSION: Diodes can be used for accurate in vivo dosimetry during prostate irradiation in high-energy photon beams. The dose delivery in this randomized trial is guaranteed within the 2.5% limits on an individual patient basis. This could not be achieved without the in vivo dosimetry program, despite our high-standard quality assurance program of treatment delivery.


Subject(s)
Prostatic Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Algorithms , Calibration , Humans , Male , Physical Phenomena , Physics , Prostatic Neoplasms/diagnostic imaging , Radiography , Radiotherapy Dosage , Radiotherapy, Conformal/instrumentation , Radiotherapy, Conformal/standards
3.
Birth Gaz ; 13(2): 6-7, 1997.
Article in English | MEDLINE | ID: mdl-9250049

ABSTRACT

The Netherlands' stubborn refusal to march in lock-step with the rest of the industrialized world, when it comes to maternity care provides important lessons for other nations. Beatrijs Smulders, author of Baren ('Giving Birth') and producer of several videos on vertical home-birthing, has been working as an Amsterdam midwife since 1979 and today plays a leading role in Dutch midwifery. Here, she explores new territory through home birth, working toward a practice both less regulated by and less reliant on prevailing institutions.


Subject(s)
Home Childbirth/nursing , Nurse Midwives/organization & administration , Female , Humans , Netherlands , Nurse Midwives/education , Pregnancy
5.
Ned Tijdschr Geneeskd ; 135(20): 893-6, 1991 May 18.
Article in Dutch | MEDLINE | ID: mdl-2046791

ABSTRACT

In the period from October 1986 to November 1988 in the Medisch Spectrum Twente of Enschede, 25 patients were treated for a tibial plateau fracture by means of arthroscopic surgery. The mean hospital stay was 18 days. Active movement of the leg was prescribed from the fifth day. The results were very good in 23 and poor in 2 patients. Complications such as wound infections and skin necrosis were not seen. Additional meniscal lesions could be diagnosed and treated better using this surgical technique. In addition, the limited incisions and consequently the avoidance of extensive arthrotomy allowed faster rehabilitation and a higher probability of healing the chondral tissue.


Subject(s)
Arthroscopy/methods , Tibial Fractures/surgery , Adolescent , Adult , Aged , Bone Screws , Female , Humans , Knee Injuries/surgery , Male , Middle Aged , Radiography , Tibial Fractures/classification , Tibial Fractures/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...