Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 31(4): 6401-6410, 2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36823897

ABSTRACT

We report on the enhancement of high harmonic generation (HHG) yield in a metasurface consisting of amorphous silicon disks in a periodic array on an insulator substrate. The structure was designed and optimized using the finite-difference time-domain method for the maximum enhancement, which reaches the factor of 20-times compared to the unstructred surface. The local field is enhanced by a broadband magnetic resonance mode allowing to use ultrashort laser pulses with Fourier transform limit down to 40 fs. Due to the anisotropic structure of the metasurface, both the local-field enhancement and the HHG yield show strong polarization anisotropy.

2.
Sensors (Basel) ; 21(3)2021 Jan 21.
Article in English | MEDLINE | ID: mdl-33494501

ABSTRACT

Ceramic-chromium Hall sensors represent a temperature and radiation resistant alternative to Hall sensors based on semiconductors. Demand for these sensors is presently motivated by the ITER and DEMO nuclear fusion projects. The developed ceramic-chromium Hall sensors were tested up to a temperature of 550 °C and a magnetic field of 14 T. The magnitude of the sensitivity of the tested sensor was 6.2 mV/A/T at 20 °C and 4.6 mV/A/T at 500 °C. The sensitivity was observed to be weakly dependent on a temperature above 240 °C with an average temperature coefficient of 0.014%/°C and independent of the magnetic field with a relative average deviation below the measurement accuracy of 0.086%. A simulation of a neutron-induced transmutation was performed to assess changes in the composition of the chromium. After 5.2 operational years of the DEMO fusion reactor, the transmuted fraction of the chromium sensitive layer was found to be 0.27% at the most exposed sensor location behind the divertor cassette with a neutron fluence of 6.08 × 1025 n/m2. The ceramic-chromium Hall sensors show the potential to be suitable magnetic sensors for environments with high temperatures and strong neutron radiation.

3.
Nat Commun ; 10(1): 5459, 2019 11 29.
Article in English | MEDLINE | ID: mdl-31784509

ABSTRACT

Non-collinear antiferromagnets are revealing many unexpected phenomena and they became crucial for the field of antiferromagnetic spintronics. To visualize and prepare a well-defined domain structure is of key importance. The spatial magnetic contrast, however, remains extraordinarily difficult to be observed experimentally. Here, we demonstrate a magnetic imaging technique based on a laser induced local thermal gradient combined with detection of the anomalous Nernst effect. We employ this method in one the most actively studied representatives of this class of materials-Mn3Sn. We demonstrate that the observed contrast is of magnetic origin. We further show an algorithm to prepare a well-defined domain pattern at room temperature based on heat assisted recording principle. Our study opens up a prospect to study spintronics phenomena in non-collinear antiferromagnets with spatial resolution.

SELECTION OF CITATIONS
SEARCH DETAIL
...