Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Neonatology ; 115(3): 263-268, 2019.
Article in English | MEDLINE | ID: mdl-30731475

ABSTRACT

BACKGROUND AND AIM: Discordant results that demand clarification have been published on diagnostic lung ultrasound (LUS) signs of transient tachypnea of the neonate (TTN) in previous cross-sectional, single-center studies. This work was conducted to correlate clinical and imaging data in a longitudinal and multicenter fashion. METHODS: Neonates with a gestational age of 34-40 weeks and presenting with TTN underwent a first LUS scan at 60-180 min of life. LUS scans were repeated every 6-12 h if signs of respiratory distress persisted. Images were qualitatively described and a LUS aeration score was calculated. Clinical data were collected during respiratory distress. RESULTS: We enrolled 65 TTN patients. Thirty-one (47.6%) had a sharp echogenicity increase in the lower lung fields (the "double lung point" or DLP sign). On admission, there was no significant difference between patients with and without DLP in Silverman scores (4 ± 1.5 vs. 4 ± 2.1; p = 0.9) or LUS scores (7.6 ± 2.6 vs. 5.6 ± 3.8; p = 0.12); PaO2/FiO2 (249 ± 93 vs. 252 ± 125; p = 0.91). All initial LUS scans (performed at the onset of distress) and 99.5% of all scans showed a regular pleural line with no consolidation, with only 1 neonate showing consolidation in the follow-up scans. The Silverman and LUS scores were significantly correlated (rho = 0.27; p = 0.02). CONCLUSION: A regular pleural line with no consolidation is a consistent finding in TTN. The presence of a DLP is not essential for the LUS diagnosis of TTN. A semi-quantitative LUS score correlates well with the clinical course and could be useful in monitoring changes in lung aeration during TTN.


Subject(s)
Lung/diagnostic imaging , Transient Tachypnea of the Newborn/diagnosis , Ultrasonography , Female , Gestational Age , Humans , Infant, Newborn , Italy , Male , Prospective Studies
2.
BMJ Case Rep ; 20142014 Dec 14.
Article in English | MEDLINE | ID: mdl-25512394

ABSTRACT

Pneumothorax is a frequent critical situation in the neonatal intensive care unit. Diagnosis relies on clinical judgement, transillumination and chest radiogram. We report the case of a very preterm infant suddenly developing significant and persistent desaturation and bradycardia. Re-intubation and cardiopulmonary resuscitation were performed. Clinical and cold light examination were not suggestive of pneumothorax according to two experienced neonatologists. A lung ultrasound scan showed evidence of right pneumothorax that was promptly aspirated. Approximately 20 min later, a chest radiogram confirmed the ultrasound diagnosis. Point-of-care lung ultrasound is a useful tool for detecting symptomatic pneumothorax and accelerating its treatment.


Subject(s)
Drainage , Emergencies , Infant, Premature , Needles , Pneumothorax/therapy , Biopsy, Needle , Bradycardia/diagnosis , Bradycardia/therapy , Critical Care , Female , Humans , Infant, Newborn , Lung , Pneumothorax/diagnostic imaging , Radiography, Thoracic , Suction , Tomography, X-Ray Computed , Ultrasonography
3.
Pediatrics ; 134(4): e1089-94, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25180278

ABSTRACT

BACKGROUND: Noninvasive ventilation is the treatment of choice for neonatal moderate respiratory distress (RD). Predictors of nasal ventilation failure are helpful in preventing clinical deterioration. Work on neonatal lung ultrasound has shown that the persistence of a hyperechogenic, "white lung" image correlates with severe distress in the preterm infant. We investigate the persistent white lung ultrasound image as a marker of noninvasive ventilation failure. METHODS: Newborns admitted to the NICU with moderate RD and stabilized on nasal continuous positive airway pressure for 120 minutes were enrolled. Lung ultrasound was performed and blindly classified as type 1 (white lung), type 2 (prevalence of B-lines), or type 3 (prevalence of A-lines). Chest radiograph also was examined and graded by an experienced radiologist blind to the infant's clinical condition. Outcome of the study was the accuracy of bilateral type 1 to predict intubation within 24 hours from scanning. Secondary outcome was the performance of the highest radiographic grade within the same time interval. RESULTS: We enrolled 54 infants (gestational age 32.5 ± 2.6 weeks; birth weight 1703 ± 583 g). Type 1 lung profile showed sensitivity 88.9%, specificity 100%, positive predictive value 100%, and negative predictive value 94.7%. Chest radiograph had sensitivity 38.9%, specificity 77.8%, positive predictive value 46.7%, and negative predictive value 71.8%. CONCLUSIONS: After a 2-hour nasal ventilation trial, neonatal lung ultrasound is a useful predictor of the need for intubation, largely outperforming conventional radiology. Future studies should address whether including ultrasonography in the management of neonatal moderate RD confers clinical advantages.


Subject(s)
Lung/diagnostic imaging , Noninvasive Ventilation/adverse effects , Respiratory Distress Syndrome, Newborn/diagnostic imaging , Respiratory Distress Syndrome, Newborn/therapy , Continuous Positive Airway Pressure/adverse effects , Continuous Positive Airway Pressure/methods , Female , Humans , Infant, Newborn , Male , Noninvasive Ventilation/methods , Predictive Value of Tests , Radiography , Single-Blind Method , Treatment Failure , Ultrasonography
4.
Crit Care ; 16(6): R220, 2012 Nov 14.
Article in English | MEDLINE | ID: mdl-23151314

ABSTRACT

INTRODUCTION: At birth, lung fluid is rapidly cleared to allow gas exchange. As pulmonary sonography discriminates between liquid and air content, we have used it to monitor extrauterine fluid clearance and respiratory adaptation in term and late preterm neonates. Ultrasound data were also related to the need for respiratory support. METHODS: Consecutive infants at 60 to 120 minutes after birth underwent lung echography. Images were classified using a standardized protocol of adult emergency medicine with minor modifications. Neonates were assigned to type 1 (white lung image), type 2 (prevalence of comet-tail artifacts or B-lines) or type 3 profiles (prevalence of horizontal or A lines). Scans were repeated at 12, 24 and 36 hours. The primary endpoint was the number of infants admitted to the neonatal ICU (NICU) by attending staff who were unaware of the ultrasound. Mode of respiratory support was also recorded. RESULTS: A total of 154 infants were enrolled in the study. Fourteen neonates were assigned to the type 1, 46 to the type 2 and 94 to the type 3 profile. Within 36 hours there was a gradual shift from types 1 and 2 to type 3. All 14 type 1 and 4 type 2 neonates were admitted to the NICU. Sensitivity was 77.7%, specificity was 100%, positive predictive value was 100%, negative predictive value was 97%. Four type 1 infants were mechanically ventilated. CONCLUSIONS: In the late preterm and term neonate, the lung ultrasound scan follows a reproducible pattern that parallels the respiratory status and can be used as a predictor of respiratory support.


Subject(s)
Lung/diagnostic imaging , Respiratory Distress Syndrome, Newborn/diagnostic imaging , Body Fluids/diagnostic imaging , Female , Humans , Infant, Newborn , Infant, Premature , Intensive Care Units, Neonatal , Male , Respiration, Artificial , Sensitivity and Specificity , Ultrasonography
5.
J Matern Fetal Neonatal Med ; 24 Suppl 1: 83-4, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21942598

ABSTRACT

Recent research links serum bilirubin levels to a positive function in human health. Yet in the neonate hyperbilirubinemia is associated to damage to the CNS and beyond. This article summarizes the evidence for the double edged role of bilirubin with a focus on the neonatal period. Also we briefly describe some of the current shortcomings in the treatment of neonatal hyperbilirubinemia.


Subject(s)
Health Knowledge, Attitudes, Practice , Hyperbilirubinemia, Neonatal/therapy , Infant Care/trends , Bilirubin/blood , Bilirubin/physiology , Humans , Hyperbilirubinemia, Neonatal/blood , Infant Care/methods , Infant, Newborn , Jaundice, Neonatal/blood , Jaundice, Neonatal/therapy , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...