Fresenius J Anal Chem ; 371(3): 364-8, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11688651

ABSTRACT

A simple and rapid flow-injection (FI) method is reported for the simultaneous spectrophotometric determination of Fe(II) and Fe(III) in pharmaceutical products. The method is based on the reaction of Fe(II) with 2,2'-dipyridyl-2-pyridylhydrazone (DPPH) in acidic medium to form a water-soluble reddish complex (lambdamax=535 nm). Fe(III) reacts with DPPH under flow conditions only after its on-line reduction by ascorbic acid (AsA). Both analytes were determined in the same run via a double-injection valve, which enabled the simultaneous injection of two sample volumes in the same carrier stream (,,single-line double-injection" approach). The two well-defined peaks produced corresponded to total iron [Fe(II)+Fe(III)] and Fe(II). Speciation of the analytes in their mixtures was achieved by multiple regression analysis. The calibration curves obtained were linear over the ranges 0-30 and 0-50 mg L(-1) for Fe(II) and Fe(II), respectively, and the precision [s(r)=1.0% for Fe(II) and 1.5% for Fe(III)] was satisfactory. The method proved to be selective and adequately sensitive (cL=0.25 and 0.17 mg L(-1) for Fe(III) and Fe(II), respectively, in mixtures). Application of the method to the analysis of pharmaceutical samples resulted in excellent accuracy; the percent mean recoveries were in the range 99.0-102.0% for both Fe(II) and Fe(III) and the mean relative error was e(r)=1.0%.


Subject(s)
2,2'-Dipyridyl/chemistry , Ferric Compounds/analysis , Ferrous Compounds/analysis , Flow Injection Analysis/methods , Hydrazones/chemistry , Pharmaceutical Preparations/analysis , 2,2'-Dipyridyl/analogs & derivatives , Capsules/analysis , Flow Injection Analysis/instrumentation , Spectrophotometry/methods , Tablets/analysis
2.
J Agric Food Chem ; 49(11): 5152-5, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11714295

ABSTRACT

The present work reports a selective and simple flow injection method for the direct and simultaneous determination of calcium and magnesium ions in red, rose, and white wines. Both ions react with methylthymol blue (MTB) at a strongly basic medium to form colored complexes that are monitored spectrophotometrically (lambda(max) = 610 nm). The simultaneous determination is achieved by online masking of magnesium by 8-hydroxyquinoline (8-HQ). Incorporating an online dilution mode based on the "zone sampling" technique in the FI system, the determination of both analytes was achieved without any pretreatment of the samples, in the range 0-350 mg L(-1) and 0-200 mg L(-1) for Ca(II) and Mg(II), respectively. The 3 sigma detection limits were quite satisfactory (2.1 and 1.8 mg L(-1) for Ca(II) and Mg(II) respectively), and the precision was 1.2% (at a mixture of 100.0 mg L(-1) Ca(II) + 100.0 mg L(-1) Mg(II), n = 12). A detailed study of interferences proved that the proposed method is highly selective. The application of the method to the direct analysis of red, rose, and white wines yielded excellent results compared with those obtained by using FAAS as a reference method (e(r) < 2.8%).


Subject(s)
Bromthymol Blue/analogs & derivatives , Calcium/analysis , Flow Injection Analysis/methods , Magnesium/analysis , Spectrophotometry/methods , Wine/analysis , Bromthymol Blue/chemistry , Indicators and Reagents/chemistry , Oxyquinoline/chemistry