Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Comput Assist Radiol Surg ; 15(10): 1611-1617, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32737859

ABSTRACT

PURPOSE: Iodine-containing contrast agent (CA) used in contrast-enhanced CT angiography (CTA) can pose a health risk for patients. A system that adjusts the frequently used standard CA dose for individual patients based on their clinical parameters can be useful. As basis the quality of the image contrast in CTA volumes has to be determined, especially to recognize excessive contrast induced by CA overdosing. However, a manual assessment with a ROI-based image contrast classification is a time-consuming step in everyday clinical practice. METHODS: We propose a method to automate the contrast measurement of aortic CTA volumes. The proposed algorithm is based on the mean HU values in selected ROIs that were automatically positioned in the CTA volume. First, an automatic localization algorithm determines the CTA image slices for certain ROIs followed by the localization of these ROIs. A rule-based classification using the mean HU values in the ROIs categorizes images with insufficient, optimal and excessive contrast. RESULTS: In 95.89% (70 out of 73 CTAs obtained with the ulrich medical CT motion contrast media injector) the algorithm chose the same image contrast class as the radiological expert. The critical case of missing an overdose did not occur with a positive predicative value of 100%. CONCLUSION: The resulting system works well within our range of considered scan protocols detecting enhanced areas in CTA volumes. Our work automized an assessment for classifying CA-induced image contrast which reduces the time needed for medical practitioners to perform such an assessment manually.


Subject(s)
Aorta/diagnostic imaging , Computed Tomography Angiography/methods , Contrast Media/administration & dosage , Tomography, X-Ray Computed/methods , Algorithms , Humans
2.
Stud Health Technol Inform ; 270: 123-127, 2020 Jun 16.
Article in English | MEDLINE | ID: mdl-32570359

ABSTRACT

Iodine-containing contrast agents (CA) are important for enhanced image contrast in CT imaging especially in CT angiography (CTA). CA however poses a risk to the patient since it can e.g. harm the kidneys. In clinical routine often a standard dose is applied that does not take differences between individual patients into account. We propose a method that as a preliminary stage determines excessive image contrast and CA overdosing by assessing the image contrast in CTA images obtained with the ulrich medical CT motion contrast media injector with RIS/PACS interface. A resulting CA dose recommendation is linked to a set of clinical parameters collected for each assessed patient. We used the established data set to implement an automatic classification for individual CA dose adjustment. The classification determines similar cases of new patients to take on the associated CA dose adjustment recommendation. The computation of similar patient data is based on the previously collected patient-individual parameters. The study shows that as basis for a recommendations the largest proportion of patients receive too much CA. A first evaluation of the automatic classification showed an overall error rate of 22% to recognize the correct class for CA dose adjustments using a k-NN-Classifier and a leave-one-out method. The classification's positive predictive value for correctly assigning a CA overdosing was 85.71%.


Subject(s)
Computed Tomography Angiography , Contrast Media , Humans , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...