Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
J Funct Biomater ; 15(5)2024 May 16.
Article in English | MEDLINE | ID: mdl-38786643

ABSTRACT

The aim of this study was to evaluate the effect of different irrigating solutions as well as their combination and activation modes on root canal dentin microhardness. The protocol was registered in PROSPERO and PRISMA guidelines were followed. The structured question was as follows: "Which type of irrigating solution used in endodontic treatment causes more change in dentin microhardness?" The literature was screened via PubMed, Google Scholar, Scopus, and Science Direct. The last search was carried out in February 2023 with English language restriction. Two reviewers independently performed screening and evaluation of articles. A total of 470 articles were retrieved from all the databases, whereas only 114 articles were selected for full-text analysis. After applying eligibility criteria, 44 studies were evaluated and included in this review. The results showed that with increased contact time with irrigants, dentin microhardness decreases. Increased contact time with sodium hypochlorite (NaOCl) was associated with more reduction in dentin microhardness compared with other irrigants. Other irrigants, with the exception of distilled water, including EDTA, citric acid, herbal irrigants, glycolic acid, phytic acid, etc., in this study significantly decreased dentin microhardness. The maximum reduction in dentin microhardness was seen with 2.5% NaOCl after 15 min of contact time. The use of irrigating solutions alters the chemical composition of dentin, thereby decreasing its microhardness, which affects the clinical performance of endodontically treated teeth.

2.
Biomolecules ; 13(11)2023 10 26.
Article in English | MEDLINE | ID: mdl-38002260

ABSTRACT

Naturally sourced products like propolis are commonly employed for the non-surgical treatment of periodontal pockets. The use of nanoparticle formulations of these natural remedies has the potential to improve treatment outcomes. The aim of the present study was to evaluate the efficacy of sub-gingivally delivered propolis nanoparticles in the non-surgical management of periodontal pockets. Forty patients diagnosed with periodontitis presenting at least one periodontal pocket with a probing pocket depth between 4 and 6 mm were selected. Patients were randomly assigned into the control group (n = 20), which received scaling and root planing (SRP) and saline (SRP + Saline), and the test group (n = 20), which received SRP and sub-gingivally delivered propolis nanoparticles (PRO) into the periodontal pocket (SRP + PRO). The clinical parameters recorded were plaque index (PI), gingival index (GI), relative attachment loss (RAL), probing pocket depth (PPD), and bleeding on probing (BOP). They were assessed at baseline, one month, and three months post therapy. The results indicated that there was a significant improvement in clinical parameters (p < 0.05) in the test sites compared with the control sites at the end of the study. The gingival index at one month and three months was found to be significantly better in the SRP + PRO group than the SRP + Saline group, with a p value of <0.001. The BOP, PPD, and RAL showed significant improvement with the SRP + PRO group at the end of the 3-month follow-up with p values of 0.0001, 0.001, and 0.05, respectively. The subgingival delivery of propolis nanoparticles showed promising results as an adjunct to SRP in patients with periodontitis presenting periodontal pockets.


Subject(s)
Periodontitis , Propolis , Humans , Periodontal Pocket/drug therapy , Propolis/therapeutic use , Periodontitis/drug therapy , Treatment Outcome , Root Planing/methods
3.
Pol Merkur Lekarski ; 50(299): 312-317, 2022 Oct 21.
Article in English | MEDLINE | ID: mdl-36283016

ABSTRACT

Native heart valve thrombosis (NHVT) is a rare valvular pathology, usually associated with prothrombotic state or disturbed intracardiac blood flow related to structural valve abnormalities. While different venous and arterial thromboembolic complications of COVID-19 have been widely described, so far NHVT has not been reported in the context of the disease. The authors describe 4 cases of NHVT associated with COVID-19, revealed on aortic, mitral (2 patients) and tricuspid valve. In a 29-yearold male with mild pneumonia, large thrombus developed on bicuspid aortic valve (BAV), which resulted in fatal brain emboli. In a 76-yearold male with a history of rheumatoid arthritis (RA) being in a recovery period after COVID-19, central retinal artery occlusion (CRAO) was the first sign of mitral valve thrombus, which disappeared after 3 weeks, during apixaban use. Such therapy was also successful in a 46-yearold female with multiple cardiovascular risk factors in whom mitral valve thrombus was found in a routine echocardiography after she got COVID-19 the third time. In a 75-year-old man with moderate COVID-19 pneumonia and bacterial coinfection, coexistent transient focal LV dysfunction and tricuspid valve thrombus were observed. The patient was treated with apixaban as well; however, in this case only reduction in the thrombus size was seen after 4 months therapy. The authors indicate that in patients with COVID-19 and NHVT, other prothrombotic conditions can usually be found. This complication may involve different valves and occur irrespective of COVID-19 severity. Interdisciplinary evaluation of such patients is necessary.


Subject(s)
COVID-19 , Coronary Thrombosis , Heart Diseases , Humans , Male , Female , Middle Aged , Aged , Adult , COVID-19/complications , Mitral Valve , Tricuspid Valve
4.
J Clin Med ; 11(20)2022 Oct 13.
Article in English | MEDLINE | ID: mdl-36294367

ABSTRACT

This study aimed to determine the prevalence and quality of endodontic treatment, by radiographically assessing the periapical periodontitis and endodontic treatment status in patients with cardiovascular disease (CVD) and cardiovascular risk (CVR) factors. Patients who visited the Out Patient Department of Institute of Dental Sciences and Department of Cardiology, Institute of Medical Sciences and SUM Hospital, Siksha 'O' Anusandhan University, Bhubaneswar, from August 2021 to February 2022, for a check-up or dental problem were considered as participants in this study. After obtaining informed consent, the participants were enrolled on the Oral Infections and Vascular Disease Epidemiology Study (INVEST) IDS, BHUBANESWAR. After testing negative for COVID-19, patients' demographic details, such as age and gender were recorded, followed by a panoramic radiographic examination (OPG). A total sample of 408 patients were divided into three groups: Group 1/control (without any cardiovascular manifestation) consisting of 102 samples, group 2 of 222 CVR patients, and group 3 of 84 CVD cases. The CVR and CVD groups had a preponderance of elderly age groups between 60 to 70 years, with a significantly higher proportion of males. Co-morbidities such as diabetes mellitus, hypertension, and dyslipidemia were significantly associated with the CVR and CVD groups. From OPG interpretation, it was observed that the periapical radiolucency was greater in the CVR and CVD groups than in the control group (p = 0.009). The prevalence of endodontically treated teeth was higher in CVR and CVD than in the control group (p = 0.028). A high prevalence of dental caries, about 70%, was reported in all three groups (p = 0.356). The presence of dental restoration among all the groups was low (p = 0.079). The proportion of periodontal bone loss in the control group was significantly lower than CVR and CVD (p = 0.000). There was a strong association between periapical radiolucency, endodontically treated teeth, and periodontal bone loss in CVR and CVD patients. Notably, the associations reported herein do not reflect a cause-effect relationship; however, individuals with endodontic pathologies may accumulate additional risk factors predisposing them to hypertension or other CVDs. The results emphasize that eliminating local infections may decrease the systemic infection burden.

5.
Polymers (Basel) ; 14(6)2022 Mar 11.
Article in English | MEDLINE | ID: mdl-35335459

ABSTRACT

The objective was to evaluate the influence of active bonding applications (ABA) for different time intervals after selective dentin etching (SDE) for 3 s on the microtensile bond strength (µTBS) to dentin of two universal adhesive systems (UAs): one containing 2-hydroxyethyl methacrylate (HEMA) (Scotchbond Universal, SBU), and one that was HEMA-free (Prime&Bond Universal, PBU). Dentin bovine specimens were divided into four groups: self-etch as control (SE), SDE + ABA for 15 s (SDE15), SDE + ABA for 20 s (SDE20), and SDE + ABA for 25 s (SDE25). The µTBS test was performed after a water storage of 24 h and 6 months. Scanning electron microscopy (SEM) was used in order to examine the resin−dentin interface. For the PBU, the µTBS was significantly influenced only by the aging factor (p < 0.026). A statistically significant decrease in the µTBS after 6 months of aging was observed only for the SDE15 group. For SBU, µTBS was significantly influenced by the protocol application and the aging time (p ≤ 0.041). The groups SDE15, SDE20, and SDE25 achieved statistically significant higher values (after 24 h and 6 months). No considerable variances were noticed in the homogeneity and continuity of the hybrid layer (HL) among the groups. In conclusion, SDE and ABA improved the µTBS only of a HEMA-containing universal adhesive.

6.
Polymers (Basel) ; 13(11)2021 Jun 04.
Article in English | MEDLINE | ID: mdl-34200021

ABSTRACT

The aim of this study was to assess the one year clinical performance of a new application method, the Fast-Modelling Bulk Technique (FMBT), in comparison to the Composite-Up Layering Technique (CULT) in posterior cavities. Thirty patients with two class I cavities on permanent human molars were enrolled in the present study. A total of sixty class I cavities were prepared and randomly divided according to the restoration technique used: 30 cavities restored by incremental layering technique and modelling of the last layer with Composite-Up Technique (CUT) using the composite Filtek Z250XT (3M ESPE; St. Paul, MN, USA) and the other 30 restored by Bulk Filling technique and modelling of the last layer by Fast-Modelling Technique (FMT) using the composite Filtek Bulk Fill Posterior Restorative (3M ESPE; St. Paul, MN, USA). Restorations were evaluated for up to one year by two observers according to Federation Dentaire Internationale (FDI) criteria, through clinical and radiological exams. Exact Fisher tests were used for statistical analysis. (p ≤ 0.05). From a biological perspective, at baseline, teeth restored with both techniques did not reveal any postoperative sensitivity. However, with time, FMBT showed less postoperative sensitivity and therefore more desirable results than CULT with a nonsignificant difference after one year (p > 0.05). Concerning secondary caries, fracture of the material, and marginal adaptation, no significant difference was noted between both techniques (p > 0.05). Regarding marginal staining, CULT resulted in more staining with a significant difference, as compared to FMBT (p < 0.05). Upon radiological examination, FMBT showed a good marginal fit during the first year, whereas CULT showed small empty voids from baseline with a nonsignificant difference (p = 1.00). After one year of clinical function, both techniques showed promising results. The present study indicates that the new FMBT could have a positive effect on the marginal staining of resin composite.

7.
Molecules ; 24(3)2019 Feb 01.
Article in English | MEDLINE | ID: mdl-30717140

ABSTRACT

There is no consensus on the antibacterial activity of dentin bonding systems (DBS). Many study models have been used to evaluate the antimicrobial activity of dental materials. In this study, a novel detection method, flow cytometry, was introduced. It allows for evaluation of the antibacterial activity of DBS, based on assessment of the disruption of the bacterial physical membrane induced by DBS. The aim of the study was to evaluate the antibacterial properties of selected dentin bonding systems against Streptococcus mutans. The highest antibacterial activity against S. mutans was observed for Adhese Universal (99.68% dead cells) and was comparable to that of Prime&Bond Universal, OptiBond Universal, or Clearfil Universal Bond Quick (p > 0.05). The lowest activity of all tested systems was displayed by the multi-mode adhesive, Universal Bond (12.68% dead bacteria cells), followed by the self-etch adhesive, OptiBond FL (15.58% dead bacteria cells). The present study showed that in the case of two-component DBS, the primer exhibited higher antimicrobial activity than the adhesive (or bond) itself.


Subject(s)
Anti-Bacterial Agents/pharmacology , Biofilms/drug effects , Dentin-Bonding Agents/pharmacology , Streptococcus mutans/drug effects , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/classification , Biofilms/growth & development , Dental Caries/microbiology , Dental Caries/prevention & control , Dentin-Bonding Agents/chemistry , Dentin-Bonding Agents/classification , Dose-Response Relationship, Drug , Flow Cytometry , Humans , Materials Testing , Microbial Sensitivity Tests , Streptococcus mutans/genetics , Streptococcus mutans/growth & development , Streptococcus mutans/metabolism
8.
Polymers (Basel) ; 10(10)2018 Oct 02.
Article in English | MEDLINE | ID: mdl-30961019

ABSTRACT

Ion-releasing polymeric restorative materials seem to be promising solutions, due to their possible anticaries effect. However, acid functional groups (monomers) and glass filler increase hydrophilicity and, supposedly, water sorption. The purpose of the study was to evaluate the influence of water sorption of polymeric materials on the stress state at the restoration-tooth interface. Beautifil Bulk Fill Flow, Beautifil Flow Plus F00, Beautifil Flow F02, Dyract eXtra, Compoglass Flow, Ionosit, Glasiosite, TwinkiStar, Ionolux and Fuji II LC were used for the study. The stress state was measured using photoelastic analysis after: 0.5, 24, 72, 96, 168, 240, 336, 504, 672, 1344 and 2016 h. Moreover, water sorption, solubility and absorption dynamic were assessed. The water sorption, solubility and absorption dynamic of ion-releasing restorative materials are material dependent properties. The overall results indicated that the tested restorative materials showed significant stress decrease. The total reduction in contraction stress and water expansion stress was not observed for materials with low value of water sorption (Beautifil Bulk Fill, Dyract eXtra, Glasionosit and Twinky Star). The photoelastic method turned out to be inadequate to evaluate stress changes of resin modified glass-ionomer cement (RMGI, Fuji II LC and Ionolux).

9.
Materials (Basel) ; 10(10)2017 Sep 28.
Article in English | MEDLINE | ID: mdl-28956844

ABSTRACT

The contraction stress generated during the photopolymerization of resin dental composites is the major disadvantage. The water sorption in the oral environment should counteract the contraction stress. The purpose was to evaluate the influence of the water sorption of composite materials on polymerization shrinkage stress generated at the restoration-tooth interface. The following materials were tested: Filtek Ultimate, Gradia Direct LoFlo, Heliomolar Flow, Tetric EvoCeram, Tetric EvoCeram Bulk Fill, Tetric EvoFlow, Tetric EvoFlow Bulk Fill, X-tra Base, Venus BulkFil, and Ceram.X One. The shrinkage stress was measured immediately after curing and after: 0.5 h, 24 h, 72 h, 96 h, 168 h, 240 h, 336 h, 504 h, 672 h, and 1344 h by means of photoelastic study. Moreover, water sorption and solubility were evaluated. Material samples were weighted on scale in time intervals to measure the water absorbency and the dynamic of this process. The tested materials during polymerization generated shrinkage stresses ranging from 6.3 MPa to 12.5 MPa. Upon water conditioning (56 days), the decrease in shrinkage strain (not less than 48%) was observed. The decrease in value stress in time is material-dependent.

10.
Biomed Res Int ; 2016: 1048320, 2016.
Article in English | MEDLINE | ID: mdl-28053976

ABSTRACT

The aim of the study was to evaluate antibacterial activity of composite materials modified with calcium fluoride against cariogenic bacteria S. mutans and L. acidophilus. One commercially available conventional light-curing composite material containing fluoride ions (F2) and two commercially available flowable light-curing composite materials (Flow Art and X-Flow) modified with 1.5, 2.5, and 5.0 wt% anhydrous calcium fluoride addition were used in the study. Composite material samples were incubated in 0.95% NaCl at 35°C for 3 days; then dilution series of S. mutans and L. acidophilus strains were made from the eluates. Bacteria dilutions were cultivated on media afterwards. Colony-forming unit per 1 mL of solution (CFU/mL) was calculated. Composite materials modified with calcium fluoride highly reduced (p < 0.001) bacteria growth compared to commercially available composite materials containing fluoride compounds. The greatest reduction in bacteria growth was observed for composite materials modified with 1.5% wt. CaF2. All three tested composite materials showed statistically greater antibacterial activity against L. acidophilus than against S. mutans.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Calcium Fluoride/therapeutic use , Streptococcus mutans/drug effects , Curing Lights, Dental/microbiology , Dental Materials/therapeutic use , Fluorides/therapeutic use , Humans , Resin Cements/therapeutic use , Streptococcus mutans/pathogenicity
11.
Acta Biochim Pol ; 61(2): 317-23, 2014.
Article in English | MEDLINE | ID: mdl-24883423

ABSTRACT

The aim of this paper was to identify and to assess in semi-quantified way the release of different ions from composite and compomer restorative materials subjected to 0.9% NaCl solution, which simulates the environment of the human body. In the present study, the number of ions (Al, Ag, Ba, Sr, Ti) released from dental fillings over time (one week, one month and 3 months), in different temperatures (23°C, 37°C) and depending on the materials applied (unmodified/modified with nanosilver) was investigated. The results suggest that nanosilver addition influences directly on the process of metal ion releasing into 0.9% NaCl solution. The increase in the number of counts of metal ions was observed in the solutions in which samples modified with nanosilver were kept. Higher amount of metal ion release was observed for composite samples rather than for compomer materials. The study revealed that in general the number of released metal ions increases with the time of storage (for metal ions: Ti, Ba, Sr) and at higher temperature (Ag, Ti, Ba). Reverse tendency observed for silver ion release versus incubation time may be caused by the process of silver adsorption, which takes place on the surface of analyzed material and test-tube walls, where samples were incubated.


Subject(s)
Compomers/analysis , Metal Nanoparticles/chemistry , Silver/chemistry , Aluminum/chemistry , Barium/chemistry , Compomers/chemistry , Compomers/radiation effects , Diffusion , Ions , Light , Sodium Chloride , Solutions , Spectrophotometry, Atomic , Strontium/chemistry , Time Factors , Titanium/chemistry
12.
Acta Bioeng Biomech ; 16(1): 51-61, 2014.
Article in English | MEDLINE | ID: mdl-24708202

ABSTRACT

Silver and gold have been used for centuries as antimicrobial agents. The aim of the study was to investigate diametral tensile strength, microhardness, ion release and light transmission of experimental resin composites. Flowable dental composite SDR (Dentsply, United Kingdom) was modified by nanogold, nanosilver and silica addition. The metal ion release, light transmission study, microhardness, Diametral Tensile Strength were evaluated. The experimental nanosilver-containing composites released significant amounts of Al, Si, Sr and Ba ions up to 30 days, and negligible silver ion amounts. Significant Ag ion release occurred in nanosilver- and nanogoldmodified composite. Resin composites modified with nanogold and nanosilver deposited on silica carrier exhibit lower light transmission and have opaque appearance. All experimental composites exhibited higher microhardness in comparison to non-modified resin composites. Diametral Tensile Strength of the experimental composites was comparable to the control group.


Subject(s)
Composite Resins/chemistry , Gold/chemistry , Materials Testing , Metal Nanoparticles/chemistry , Silver/chemistry , Gold Isotopes , Light , Spectrophotometry, Atomic , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...