Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Cardiovasc Intervent Radiol ; 46(12): 1755-1757, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37950088
2.
Br J Radiol ; 95(1138): 20220434, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-35776630

ABSTRACT

Liver was the very first organ for which interventional procedures were applied for the local treatment of primary and secondary malignancies. In this paper, the history of Interventional Oncology of liver, from the very beginning to the current situation, is summarized, including both percutaneous and intravascular procedures, and together with the evolution of the techniques for image guidance. The main ongoing developments, such as new techniques, combined interventional treatments and association of local interventions with new drugs are briefly described, too.


Subject(s)
Endovascular Procedures , Liver Neoplasms , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Medical Oncology/methods , Radiology, Interventional/methods
3.
Cancers (Basel) ; 14(5)2022 Mar 03.
Article in English | MEDLINE | ID: mdl-35267620

ABSTRACT

Background: Over the last two decades, augmented reality (AR) has been used as a visualization tool in many medical fields in order to increase precision, limit the radiation dose, and decrease the variability among operators. Here, we report the first in vivo study of a novel AR system for the guidance of percutaneous interventional oncology procedures. Methods: Eight patients with 15 liver tumors (0.7−3.0 cm, mean 1.56 + 0.55) underwent percutaneous thermal ablations using AR guidance (i.e., the Endosight system). Prior to the intervention, the patients were evaluated with US and CT. The targeted nodules were segmented and three-dimensionally (3D) reconstructed from CT images, and the probe trajectory to the target was defined. The procedures were guided solely by AR, with the position of the probe tip was subsequently confirmed by conventional imaging. The primary endpoints were the targeting accuracy, the system setup time, and targeting time (i.e., from the target visualization to the correct needle insertion). The technical success was also evaluated and validated by co-registration software. Upon completion, the operators were assessed for cybersickness or other symptoms related to the use of AR. Results: Rapid system setup and procedural targeting times were noted (mean 14.3 min; 12.0−17.2 min; 4.3 min, 3.2−5.7 min, mean, respectively). The high targeting accuracy (3.4 mm; 2.6−4.2 mm, mean) was accompanied by technical success in all 15 lesions (i.e., the complete ablation of the tumor and 13/15 lesions with a >90% 5-mm periablational margin). No intra/periprocedural complications or operator cybersickness were observed. Conclusions: AR guidance is highly accurate, and allows for the confident performance of percutaneous thermal ablations.

SELECTION OF CITATIONS
SEARCH DETAIL