1.
J Cataract Refract Surg
; 44(3): 259-261, 2018 03.
Article
in English
| MEDLINE
| ID: mdl-29550040
ABSTRACT
We describe a technique to simplify the retrieval process of an intraocular lens (IOL) that has fallen into the posterior segment of the eye. A high-vacuum level setting is used to achieve fixation of the IOL to the vitrectomy tip, permitting the IOL to be elevated into the anterior segment. The clothesline technique is then used to secure the IOL partially within the anterior chamber for subsequent suture fixation or explantation. This technique simplifies the elevation, repositioning, and/or explantation of a posteriorly dislocated IOL and eliminates the need to perform more complex and potentially traumatic maneuvers.