Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Oman J Ophthalmol ; 15(3): 290-294, 2022.
Article in English | MEDLINE | ID: mdl-36760940

ABSTRACT

PURPOSE: The purpose of this study is to evaluate and compare the accuracy of Barrett Universal II versus third-generation formula for different intraocular lens (IOL) powers for Indian eyes with different axial lengths (ALs). DESIGN: This is a retrospective, nonrandomized consecutive case series. METHODS: This study reviewed 981 eyes from 825 patients who had uneventful cataract surgery and IOL implantation. The eyes were separated into subgroups based on AL as follows: short (<22.0 mm), medium (22.01-23.99 mm), and long (>24.0 mm). The predicted refractive outcome using formulas was calculated and compared with the actual refractive outcome to give the prediction error. The percentage of every refractive error absolute value for each formula was calculated at <±0.50D, 0.50D-0.75D, and >±0.75D. RESULTS: In all, 981 eyes were analyzed. There were no significant differences in the median absolute error predicted by Barrett and the third-generation formulae. The Barrett Universal II formula resulted in significantly lowest mean spherical equivalent in short eyes (P = 0.0047) as well as a higher percentage of eyes with prediction errors within <±0.50D, 0.50D-0.75D, and >±0.75D. We found that the Barrett Universal II formula had the lowest predictive refraction error and mean absolute error across all ALs. CONCLUSION: The Barrett Universal II formula rendered the lowest predictive error compared with SRK/T, Holladay, and Hoffer Q formulas. Thus, the Barrett Universal II formula may be regarded as a more reliable formula for achieving emmetropia and reducing postoperative refractive surprises across all ALs.

2.
Oman J Ophthalmol ; 11(3): 227-231, 2018.
Article in English | MEDLINE | ID: mdl-30505112

ABSTRACT

AIM: The aim of this study is to compare the surgical outcomes of pterygium excision with conjunctival autograft using sutures, fibrin glue (tisseel), and autologous blood for the management of primary pterygium. PATIENTS AND METHODS: A retrospective study done in 681 eyes with primary nasal pterygium. Excision of the pterygium was performed followed by closure of the bare sclera with conjunctival autograft using interrupted 10-0 monofilament nylon sutures in 173 eyes (Group 1), fibrin glue (tisseel-baxter healthcare corporation, westlake village, ca-91362 USA) in 351 eyes (Group 2), and autologous blood in 157 eyes (Group 3). Patients were followed up for a period of 5-52 months. During follow-up, graft-related complications such as recurrence, graft loss, graft retraction, granuloma if any were noted and compared among the three groups. RESULTS: A total of 681 eyes who had primary nasal pterygium were included in this study. Pterygium excision with conjunctival autograft was performed using 10-0 monofilament nylon interrupted sutures in 173 eyes (25.4%), tisseel fibrin glue in 351 eyes (51.54%), and autologous blood in 157 (23.05%) eyes. The mean duration of follow-up was 5-52 months. The overall recurrence rate was 2.9% (20 eyes). In Group 1, recurrence was seen in 5 eyes (2.89%), in Group 2, it was seen in 7 eyes (1.99%) and in Group 3, 8 eyes (5.10%). However, the recurrence rate was not significant (P = 0.160). The rate of graft retraction in the 3 study groups were 12 eyes (6.94%), 10 eyes (2.85%), and 56 eyes (35.67%) with a significant P < 0.001. Granuloma was seen in 2 eyes (1.16%), in Group 1, and in 1 eye (0.64%) in Group 3. Graft loss was seen in 3 eyes (1.73%), 4 eyes (1.14%), 6 eyes (3.82%) in Group 1, 2, and 3, respectively. CONCLUSION: The outcomes of the three most commonly performed surgical technique of conjunctival autograft fixation has shown us that all three techniques are equally comparable and can be offered to our patients with equally good results.

SELECTION OF CITATIONS
SEARCH DETAIL
...