Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
Biomed Microdevices ; 19(3): 62, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28688070

ABSTRACT

Over the last several years, there has been a growing interest in neural implants for the study and diagnostics of neurological disorders as well as for the symptomatic treatment of central nervous system related diseases. One of the major challenges is the trade-off between small electrode sizes for high selectivity between single neurons and large electrode-tissue interface areas for excellent stimulation and recording properties. This paper presents an approach of increasing the real surface area of the electrodes by creating a surface microstructure. Two major novelties let this work stand out from existing approaches which mainly make use of porous coatings such as platinum black or iridium oxide, or Poly(3,4-ethylenedioxythiophene) (PEDOT). Roughening is carried out by a dry etching process on the silicon electrode core before being coated by a sputtered platinum layer, eliminating complicated deposition processes as for the materials described above. The technology is compatible with any commonly used coating material. In addition, the surface roughening is compatible with high aspect ratio penetrating electrode arrays such as the well-established Utah electrode array, whose unique geometry presents a challenge in the surface modification of active electrode sites. The dry etching process is well characterized and yields a high controllability of pore size and depth. This paper confirms the superior electrochemical properties including impedance, charge injection capacity, and charge storage capacity of surface engineered electrode arrays compared to conventional arrays over a period of 12 weeks. Furthermore, mechanical stability of the modified electrodes was tested by implantation in the brain of a recently deceased rat. In conclusion, the larger interface surface of the electrodes does not only decrease the impedance which should lead to enhanced Signal to noise ratio (SNR) for recording purposes, but also yields higher charge injection capacities, which improve the stimulation characteristics of the implants.


Subject(s)
Electrodes, Implanted , Nervous System , Platinum , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Electric Impedance , Electrochemistry , Equipment Design , Platinum/chemistry , Polymers/chemistry , Porosity , Time Factors
2.
Appl Surf Sci ; 365: 180-190, 2016 Mar 01.
Article in English | MEDLINE | ID: mdl-26806992

ABSTRACT

In various applications such as neural prostheses or solar cells, there is a need to alter the surface morphology of high aspect ratio structures so that the real surface area is greater than geometrical area. The change in surface morphology enhances the devices functionality. One of the applications of altering the surface morphology is of neural implants such as the Utah electrode array (UEA) that communicate with single neurons by charge injection induced stimulation or by recording electrical neural signals. For high selectivity between single cells of the nervous system, the electrode surface area is required to be as small as possible, while the impedance is required to be as low as possible for good signal to noise ratios (SNR) during neural recording. For stimulation, high charge injection and charge transfer capacities of the electrodes are required, which increase with the electrode surface. Traditionally, researchers have worked with either increasing the roughness of the existing metallization (Platinum grey, black) or other materials such as Iridium Oxide and PEDOT. All of these previously investigated methods lead to more complicated metal deposition processes that are difficult to control and often have a critical impact on the mechanical properties of the metal films. Therefore, a modification of the surface underneath the electrode's coating will increase its surface area while maintaining the standard and well controlled metal deposition process. In this work, the surfaces of the Silicon micro-needles were engineered by creating a defined microstructure on the electrodes surface using several methods such as Laser ablation, focused ion beam, sputter etching, reactive ion etching (RIE) and deep reactive ion etching (DRIE). The surface modification processes were optimized for the high aspect ratio Silicon structures of the UEA. The increase in real surface area while maintaining the geometrical surface area was verified using scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The best results were obtained by DRIE induced surface morphology. Decreases in impedance values of electrodes up to 76 % indicate the successful surface engineering of the high aspect ratio Silicon structures.

3.
Biosens Bioelectron ; 77: 149-56, 2016 Mar 15.
Article in English | MEDLINE | ID: mdl-26402593

ABSTRACT

Continuous glucose monitoring (CGM) sensors are often advocated as a clinical solution to improve long-term glycemic control in the context of diabetes. Subcutaneous sensor inflammatory response, fouling and fibrous encapsulation resulting from the host foreign body response (FBR) reduce sensor sensitivity to glucose, eventually resulting in sensor performance compromise and device failure. Several combination device strategies load CGM sensors with drug payloads that release locally to tissue sites to mitigate FBR-mediated sensor failure. In this study, the mast cell-targeting tyrosine kinase inhibitor, masitinib, was released from degradable polymer microspheres delivered from the surfaces of FDA-approved human commercial CGM needle-type implanted sensors in a rodent subcutaneous test bed. By targeting the mast cell c-Kit receptor and inhibiting mast cell activation and degranulation, local masitinib penetration around the CGM to several hundred microns sought to reduce sensor fibrosis to extend CGM functional lifetimes in subcutaneous sites. Drug-releasing and control CGM implants were compared in murine percutaneous implant sites for 21 days using direct-wire continuous glucose reporting. Drug-releasing implants exhibited no significant difference in CGM fibrosis at implant sites but showed relatively stable continuous sensor responses over the study period compared to blank microsphere control CGM implants.


Subject(s)
Blood Glucose Self-Monitoring/instrumentation , Blood Glucose/analysis , Blood Glucose/drug effects , Drug Implants/administration & dosage , Prostheses and Implants , Thiazoles/administration & dosage , Animals , Benzamides , Biosensing Techniques/instrumentation , Equipment Design , Equipment Failure Analysis , Male , Mice , Mice, Inbred C57BL , Piperidines , Pyridines , Reproducibility of Results , Sensitivity and Specificity
4.
Acta Biomater ; 10(5): 1856-63, 2014 May.
Article in English | MEDLINE | ID: mdl-24406200

ABSTRACT

Mast cells (MCs)_are recognized for their functional role in wound-healing and allergic and inflammatory responses - host responses that are frequently detrimental to implanted biomaterials if extended beyond acute reactivity. These tissue reactions impact especially on the performance of sensing implants such as continuous glucose monitoring (CGM) devices. Our hypothesis that effective blockade of MC activity around implants could alter the host foreign body response (FBR) and enhance the in vivo lifetime of these implantable devices motivated this study. Stem cell factor and its ligand c-KIT receptor are critically important for MC survival, differentiation and degranulation. Therefore, an MC-deficient sash mouse model was used to assess MC relationships to the in vivo performance of CGM implants. Additionally, local delivery of a tyrosine kinase inhibitor (TKI) that inhibits c-KIT activity was also used to evaluate the role of MCs in modulating the FBR. Model sensor implants comprising polyester fibers coated with a rapidly dissolving polymer coating containing drug-releasing degradable microspheres were implanted subcutaneously in sash mice for various time points, and the FBR was evaluated for chronic inflammation and fibrous capsule formation around the implants. No significant differences were observed in the foreign body capsule formation between control and drug-releasing implant groups in MC-deficient mice. However, fibrous encapsulation was significantly greater around the drug-releasing implants in sash mice compared to drug-releasing implants in wild-type (e.g. MC-competent) mice. These results provide insights into the role of MCs in the FBR, suggesting that MC deficiency provides alternative pathways for host inflammatory responses to implanted biomaterials.


Subject(s)
Biocompatible Materials/adverse effects , Foreign-Body Reaction/immunology , Implants, Experimental/adverse effects , Mast Cells/pathology , Subcutaneous Tissue/immunology , Animals , Cell Count , Disease Models, Animal , Fibrosis , Foreign Bodies/immunology , Foreign Bodies/pathology , Foreign-Body Reaction/pathology , Inflammation/pathology , Lactic Acid/chemistry , Male , Mice , Mice, Inbred C57BL , Polyethylene Glycols/chemistry , Polyglycolic Acid/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer , Proto-Oncogene Proteins c-kit/metabolism , Subcutaneous Tissue/pathology
5.
J Neural Eng ; 10(4): 045003, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23723133

ABSTRACT

OBJECTIVE: Among the currently available neural interface devices, there has been a need for a penetrating electrode array with a high electrode-count and high electrode-density (the number of electrodes/mm(2)) that can be used for electrophysiological studies of sub-millimeter neuroanatomical structures. We have developed such a penetrating microelectrode array with both a high electrode-density (25 electrodes/mm(2)) and high electrode-count (up to 96 electrodes) for small nervous system structures, based on the existing Utah Slanted Electrode Array (USEA). Such high electrode-density arrays are expected to provide greater access to nerve fibers than the conventionally spaced USEA especially in small diameter nerves. APPROACH: One concern for such high density microelectrode arrays is that they may cause a nerve crush-type injury upon implantation. We evaluated this possibility during acute (<10 h) in vivo experiments with electrode arrays implanted into small diameter peripheral nerves of anesthetized rats (sciatic nerve) and cats (pudendal nerve). MAIN RESULTS: Successful intrafascicular implantation and viable nerve function was demonstrated via microstimulation, single-unit recordings and histological analysis. Measurements of the electrode impedances and quantified electrode dimensions demonstrated fabrication quality. The results of these experiments show that such high density neural interfaces can be implanted acutely into neural tissue without causing a complete nerve crush injury, while mediating intrafascicular access to fibers in small diameter peripheral nerves. SIGNIFICANCE: This new penetrating microelectrode array has characteristics un-matched by other neural interface devices currently available for peripheral nervous system neurophysiological research.


Subject(s)
Diagnostic Techniques, Neurological/instrumentation , Electric Stimulation/instrumentation , Electrodes, Implanted , Microarray Analysis/instrumentation , Microelectrodes , Nanotechnology/instrumentation , Peripheral Nerves/physiology , Animals , Cats , Electric Impedance , Equipment Design , Equipment Failure Analysis , Rats , Rats, Sprague-Dawley
6.
Biomed Opt Express ; 3(12): 3087-104, 2012 Dec 01.
Article in English | MEDLINE | ID: mdl-23243561

ABSTRACT

This paper presents optical characterization of a first-generation SiO(2) optrode array as a set of penetrating waveguides for both optogenetic and infrared (IR) neural stimulation. Fused silica and quartz discs of 3-mm thickness and 50-mm diameter were micromachined to yield 10 × 10 arrays of up to 2-mm long optrodes at a 400-µm pitch; array size, length and spacing may be varied along with the width and tip angle. Light delivery and loss mechanisms through these glass optrodes were characterized. Light in-coupling techniques include using optical fibers and collimated beams. Losses involve Fresnel reflection, coupling, scattering and total internal reflection in the tips. Transmission efficiency was constant in the visible and near-IR range, with the highest value measured as 71% using a 50-µm multi-mode in-coupling fiber butt-coupled to the backplane of the device. Transmittance and output beam profiles of optrodes with different geometries was investigated. Length and tip angle do not affect the amount of output power, but optrode width and tip angle influence the beam size and divergence independently. Finally, array insertion in tissue was performed to demonstrate its robustness for optical access in deep tissue.

7.
Biomed Opt Express ; 3(9): 2200-19, 2012 Sep 01.
Article in English | MEDLINE | ID: mdl-23024914

ABSTRACT

This paper characterizes the Utah Slant Optrode Array (USOA) as a means to deliver infrared light deep into tissue. An undoped crystalline silicon (100) substrate was used to fabricate 10 × 10 arrays of optrodes with rows of varying lengths from 0.5 mm to 1.5 mm on a 400-µm pitch. Light delivery from optical fibers and loss mechanisms through these Si optrodes were characterized, with the primary loss mechanisms being Fresnel reflection, coupling, radiation losses from the tapered shank and total internal reflection in the tips. Transmission at the optrode tips with different optical fiber core diameters and light in-coupling interfaces was investigated. At λ = 1.55µm, the highest optrode transmittance of 34.7%, relative to the optical fiber output power, was obtained with a 50-µm multi-mode fiber butt-coupled to the optrode through an intervening medium of index n = 1.66. Maximum power is directed into the optrodes when using fibers with core diameters of 200 µm or less. In addition, the output power varied with the optrode length/taper such that longer and less tapered optrodes exhibited higher light transmission efficiency. Output beam profiles and potential impacts on physiological tests were also examined. Future work is expected to improve USOA efficiency to greater than 64%.

8.
Sens Actuators A Phys ; 188: 167-172, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23288983

ABSTRACT

The encapsulation and packaging reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA)/integrated neural interface-recording version 5 (INI-R5) has been evaluated by monitoring the extended long term in-vitro functional stability and recording longevity. The INI encapsulated with 6-µm Parylene-C was immersed in phosphate buffer saline (PBS) at room temperature for a period of over 12 months. The USEA/INI-R5, while being soaked was powered and configured wirelessly through 2.765 MHz inductive link and the transmitted frequency shift keying (FSK) modulated radio-frequency (RF) (900 MHz Industrial, scientific, medical-ISM band) signal was also recorded wirelessly as a function of soak time. In order to test the long term recording ability, in-vitro wireless recording was performed in agarose for few channels. The full functionality and the ability of the electrodes to record artificial neural signals even after 12 months of PBS soak provides a measure of encapsulation reliability, the functional and recording stability in fully integrated wireless neural interface and potential usefulness for future chronic implants.

9.
Sens Actuators B Chem ; 160(1): 1363-1371, 2011 Dec 15.
Article in English | MEDLINE | ID: mdl-22190765

ABSTRACT

Because the boronic acid moiety reversibly binds to sugar molecules and has low cytotoxicity, boronic acid-containing hydrogels are being used in a variety of implantable glucose sensors under development, including sensors based on optical, fluorescence, and swelling pressure measurements. However, some method of glucose selectivity enhancement is often necessary, because isolated boronic acid molecules have a binding constant with glucose that is some forty times smaller than their binding constant with fructose, the second most abundant sugar in the human body. In many cases, glucose selectivity enhancement is obtained by incorporating pendant tertiary amines into the hydrogel network, thereby giving rise to a hydrogel that is zwitterionic at physiological pH. However, the mechanism by which incorporation of tertiary amines confers selectivity enhancement is poorly understood. In order to clarify this mechanism, we use the osmotic deswelling technique to compare the thermodynamic interactions of glucose and fructose with a zwitterionic smart hydrogel containing boronic acid moieties. We also investigate the change in the structure of the hydrogel that occurs when it binds to glucose or to fructose using the technique of small angle neutron scattering.

10.
Sens Actuators A Phys ; 162(1): 130-136, 2010 Jul 01.
Article in English | MEDLINE | ID: mdl-20706618

ABSTRACT

Microsystem technology is well suited to batch fabricate microelectrode arrays, such as the Utah electrode array (UEA), intended for recording and stimulating neural tissue. Fabrication of the UEA is primarily based on the use of dicing and wet etching to achieve high aspect ratio (15:1) penetrating electrodes. An important step in the array fabrication is the etching of electrodes to produce needle-shape electrodes with sharp tips. Traditional etching processes are performed on a single array, and the etching conditions are not optimized. As a result, the process leads to variable geometries of electrodes within an array. Furthermore, the process is not only time consuming but also labor-intensive. This report presents a wafer-scale etching method for the UEA. The method offers several advantages, such as substantial reduction in the processing time, higher throughput and lower cost. More importantly, the method increases the geometrical uniformity from electrode to electrode within an array (1.5 ± 0.5 % non-uniformity), and from array to array within a wafer (2 ± 0.3 % non-uniformity). Also, the etching rate of silicon columns, produced by dicing, are studied as a function of temperature, etching time and stirring rate in a nitric acid rich HF-HNO(3) solution. These parameters were found to be related to the etching rates over the ranges studied and more-importantly affect the uniformity of the etched silicon columns. An optimum etching condition was established to achieve uniform shape electrode arrays on wafer-scale.

11.
Sens Actuators A Phys ; 161(1-2): 29-38, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20657810

ABSTRACT

Hydrogels have been demonstrated to swell in response to a number of external stimuli including pH, CO(2), glucose, and ionic strength making them useful for detection of metabolic analytes. To measure hydrogel swelling pressure, we have fabricated and tested novel perforated diaphragm piezoresistive pressure sensor arrays that couple the pressure sensing diaphragm with a perforated semi-permeable membrane. The 2×2 arrays measure approximately 3 × 5 mm(2) and consist of four square sensing diaphragms with widths of 1.0, 1.25, and 1.5 mm used to measure full scale pressures of 50, 25, and 5 kPa, respectively. An optimized geometry of micro pores was etched in silicon diaphragm to allow analyte diffusion into the sensor cavity where the hydrogel material is located. The 14-step front side wafer process was carried out by a commercial foundry service (MSF, Frankfurt (Oder), Germany) and diaphragm pores were created using combination of potassium hydroxide (KOH) etching and deep reactive ion etching (DRIE).Sensor characterization was performed (without the use of hydrogels) using a custom bulge testing apparatus that simultaneously measured deflection, pressure, and electrical output. Test results are used to quantify the sensor sensitivity and demonstrate proof-of-concept. Simulations showed that the sensitivity was slightly improved for the perforated diaphragm designs while empirical electrical characterization showed that the perforated diaphragm sensors were slightly less sensitive than solid diaphragm sensors. This discrepancy is believed to be due to the influence of compressive stress found within passivation layers and poor etching uniformity. The new perforated diaphragm sensors were fully functional with sensitivities ranging from 23 to 252 µV/V-kPa (FSO= 5 to 80mV), and show a higher nonlinearity at elevated pressures than identical sensors with solid diaphragms. Sensors (1.5×1.5 mm(2)) with perforated diaphragms (pores=40 µm) have a nonlinearity of approximately 10% while for the identical solid diaphragm sensor it was roughly 3 % over the entire 200 kPa range. This is the first time piezoresistive pressure sensors with integrated diffusion pores for detection of hydrogel swelling pressure have been fabricated and tested.

12.
Rev Sci Instrum ; 81(5): 055111, 2010 May.
Article in English | MEDLINE | ID: mdl-20515176

ABSTRACT

A wafer scale bulge testing system has been constructed to study the mechanical properties of thin films and microstructures. The custom built test stage was coupled with a pressure regulation system and optical profilometer which gives high accuracy three-dimensional topographic images collected on the time scale of seconds. Membrane deflection measurements can be made on the wafer scale (50-150 mm) with up to nanometer-scale vertical resolution. Gauge pressures up to 689 kPa (100 psi) are controlled using an electronic regulator with and accuracy of approximately 0.344 kPa (0.05 psi). Initial testing was performed on square diaphragms 350, 550, and 1200 microm in width comprised of 720+/-10 nm thick low pressure chemical vapor deposited silicon nitride with approximately 20 nm of e-beam evaporated aluminum. These initial experiments were focused on measuring the system limitations and used to determine what range of deflections and pressures can be accurately measured and controlled. Gauge pressures from 0 to approximately 8.3 kPa (1.2 psi) were initially applied to the bottom side of the diaphragms and their deflection was subsequently measured. The overall pressure resolution of the system is good (approximately 350 Pa) but small fluctuations existed at pressures below 5 kPa leading to a larger standard deviation between deflection measurements. Analytical calculations and computed finite element analysis deflections closely matched those empirically measured. Using an analytical solution that relates pressure deflection data for the square diaphragms the Young's modulus was estimated for the films assuming a Poisson's ratio of v=0.25. Calculations to determine Young's modulus for the smaller diaphragms proved difficult because the pressure deflection relationship remained in the linear regime over the tested pressure range. Hence, the calculations result in large error when used to estimate the Young's modulus for the smaller membranes. The deflection measurements of three 1200 x 1200 microm(2) Si(3)N(4-x) membranes were taken at increased pressures (>25 kPa) to increase nonlinearity and better determine Young's modulus. This pressure-deflection data were fit to an analytical solution and Young's modulus estimated to be 257+/-3 GPa, close to those previously reported in literature.


Subject(s)
Hardness Tests/instrumentation , Materials Testing/instrumentation , Membranes, Artificial , Transducers , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
13.
Biomed Mater ; 5(1): 15007, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20124668

ABSTRACT

Neural interfaces connect signal processing electronics to the nervous system via implanted microelectrode arrays such as the Utah electrode array (UEA). The active sites of the UEA are coated with thin films of either platinum (Pt) or iridium oxide (IrOx). Pt and IrOx have attracted attention as a stimulating or recording material due to their ability to transfer between ionic and electronic current and to resist corrosion. The physical, mechanical, chemical, electrical and optical properties of thin films depend on the method and deposition parameters used to deposit the films. In this work, surface morphology, impedance and charge capacity of Pt and sputtered iridium oxide film (SIROF) were investigated and compared with each other. UEAs with similar electrode area and shape were employed in this study. DC sputtering was used to deposit Pt films and pulsed-dc reactive sputtering was used to deposit SIROF. The electrodes coated with SIROF and Pt were characterized by scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy and potential transient measurements to measure charge injection capacity (CIC). SIROF and Pt selectively deposited on the electrode tip had dendrite and granular microstructure, respectively. The CIC of unbiased SIROF and Pt was 2 and 0.3 mC cm(-2), respectively. The average impedance at 1 kHz, of SIROF and Pt electrodes, was 6 kOmega and 125 kOmega, respectively. Low impedance and high CIC make SIROF promising stimulation/recording material for neural prosthetic applications.


Subject(s)
Coated Materials, Biocompatible/chemistry , Electrodes, Implanted , Iridium/chemistry , Microelectrodes , Platinum/chemistry , Electric Conductivity , Equipment Design , Equipment Failure Analysis , Hot Temperature , Materials Testing , Surface Properties
14.
Sens Actuators B Chem ; 144(1): 332, 2010 Jan 29.
Article in English | MEDLINE | ID: mdl-20161690

ABSTRACT

In the last few years, a new type of glucose-sensitive hydrogel (GSH) has been developed that shrinks with increasing glucose concentration due to the formation of reversible crosslinks The first osmotic swelling pressure results measured for any member of this new class of GSH are reported, so that their suitability for use in sensors combining pressure transducers and smart gels can be evaluated. Comparison is also made with results obtained for an older type of GSH that expands with increasing glucose concentration due to an increase in the concentration of counterions within the gel. The newer type of GSH exhibits both faster kinetics and weaker fructose interference, and therefore is more suitable for in vivo glucose sensing.

15.
Sens Actuators B Chem ; 145(2): 807-816, 2010 Mar 19.
Article in English | MEDLINE | ID: mdl-23750073

ABSTRACT

This report details the first experimental results from novel hydrogel sensor array (2 × 2) which incorporates analyte diffusion pores into a piezoresistive diaphragm for the detection of hydrogel swelling pressures and hence chemical concentrations. The sensor assembly was comprised of three components, the active four sensors, HPMA/DMA/TEGDMA (hydroxypropyl methacrylate (HPMA), N,N-dimethylaminoethyl methacrylate (DMA) and crosslinker tetra-ethyleneglycol dimethacrylate (TEGDMA)) hydrogel, and backing plate. Each of the individual sensors of the array can be used with various hydrogels used to measure the presence of a number of stimuli including pH, ionic strength, and glucose concentrations. Ideally, in the future, these sensors will be used for continuous metabolic monitoring applications and implanted subcutaneously. In this paper and to properly characterize the sensor assembly, hydrogels sensitive to changes ionic strength were synthesized using hydroxypropyl methacrylate (HPMA), N,N-dimethylaminoethyl methacrylate (DMA) and crosslinker tetra-ethyleneglycol dimethacrylate (TEGDMA) and inserted into the sensor assembly. This hydrogel quickly and reversibly swells when placed environments of physiological buffer solutions (PBS) with ionic strengths ranging from 0.025 to 0.15 M, making it ideal for proof-of-concept testing and initial characterization. The assembly was wire bonded to a printed circuit board and coated with 3 ± 0.5 µm of Parylene-C using chemical vapor deposition (CVD) to protect the sensor and electrical connections during ionic strength wet testing. Two versions of sensors were fabricated for comparison, the first incorporated diffusion pores into the diaphragm, and the second used a solid diaphragm with perforated backing plate. This new design (perforated diaphragm) was shown to have slightly higher sensitivity than solid diaphragm sensors with separate diffuse backing plates when coupled with the hydrogel. The sensitivities for the 1 mm × 1 mm, 1.25 mm × 1.25 mm, 1.5 mm × 1.5 mm perforated diaphragm sensors were 53.3 ± 6.5, 171.7 ± 8.8, and 271.47 ± 27.53 mV/V-M, respectively. These results show that perforations in the diaphragm can be used not only to allow the diffusion of analyte into the cavity but to increase mechanical stress in the piezoresistive diaphragm, thereby increasing sensor output signal. The time constants for swelling (τswelling) and contracting (τcontracting) were calculated by fitting the sensor output half cycles to an exponential growth function. We found that the sensors' response was initially retarded during the preliminary hydrogel conditioning period then improved after 3-5 cycles with values of approximately 9 and 7 min for τswelling and τcontracting. For all sensors tested τswelling > τcontracting. This may be due to the increased loading on the hydrogel from the diaphragm during the swelling process. During contraction the diaphragm aids the hydrogel by reversibly applying mechanical pressure and therefore reducing τcontracting. Long term stability testing showed the sensors remained functional for upwards of 2 weeks in the test phosphate buffer solution (PBS).

16.
Biomed Microdevices ; 11(2): 453-66, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19067174

ABSTRACT

This report presents results from research towards a fully integrated, wireless neural interface consisting of a 100-channel microelectrode array, a custom-designed signal processing and telemetry IC, an inductive power receiving coil, and SMD capacitors. An integration concept for such a device was developed, and the materials and methods used to implement this concept were investigated. We developed a multi-level hybrid assembly process that used the Utah Electrode Array (UEA) as a circuit board. The signal processing IC was flip-chip bonded to the UEA using Au/Sn reflow soldering, and included amplifiers for up to 100 channels, signal processing units, an RF transmitter, and a power receiving and clock recovery module. An under bump metallization (UBM) using potentially biocompatible materials was developed and optimized, which consisted of a sputter deposited Ti/Pt/Au thin film stack with layer thicknesses of 50/150/150 nm, respectively. After flip-chip bonding, an underfiller was applied between the IC and the UEA to improve mechanical stability and prevent fluid ingress in in vivo conditions. A planar power receiving coil fabricated by patterning electroplated gold films on polyimide substrates was connected to the IC by using a custom metallized ceramic spacer and SnCu reflow soldering. The SnCu soldering was also used to assemble SMD capacitors on the UEA. The mechanical properties and stability of the optimized interconnections between the UEA and the IC and SMD components were measured. Measurements included the tape tests to evaluate UBM adhesion, shear testing between the Au/Sn solder bumps and the substrate, and accelerated lifetime testing of the long-term stability for the underfiller material coated with a a-SiC(x):H by PECVD, which was intended as a device encapsulation layer. The materials and processes used to generate the integrated neural interface device were found to yield a robust and reliable integrated package.


Subject(s)
Electrodes, Implanted , Electrophysiology/instrumentation , Microelectrodes , Signal Processing, Computer-Assisted/instrumentation , Telemetry/instrumentation , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity , Systems Integration , Telemetry/methods
17.
Sens Actuators B Chem ; 136(1): 186, 2009 Feb 02.
Article in English | MEDLINE | ID: mdl-20130753

ABSTRACT

We investigate thin films of "smart" polymer hydrogels used to convert miniature pressure sensors into novel chemomechanical sensors. In this versatile sensing approach, a smart hydrogel is confined between a porous membrane and the diaphragm of a piezoresistive pressure transducer. An increase in the environmental analyte concentration, as sensed through the pores of the membrane, is detected by measuring the change in pressure exerted by the hydrogel on the pressure transducer diaphragm. We compare the response of such a sensor with the response of a free-swelling hydrogel identical to the one used within the sensor. The sensor and the free hydrogel are observed to have comparable mean response times. However, the time-dependent response curve of the sensor, unlike that of the free hydrogel, is highly asymmetric between swelling and deswelling, with a smaller time constant for deswelling. We also investigate novel methods for increasing sensor sensitivity, such as use of a two-layer membrane with a nanoporous polymer inner layer, and pre-loading of the hydrogel under pressure. In ionic strength response tests, use of an inner membrane increases sensor sensitivity without increasing mean response time, an effect that varies with membrane water fraction.

18.
Sens Actuators A Phys ; 145-146(1-2): 123-130, 2008.
Article in English | MEDLINE | ID: mdl-19122774

ABSTRACT

A novel fabrication technique has been developed for creating high density (6.25 electrodes/mm(2)), out of plane, high aspect ratio silicon-based convoluted microelectrode arrays for neural and retinal prostheses. The convoluted shape of the surface defined by the tips of the electrodes could compliment the curved surfaces of peripheral nerves and the cortex, and in the case of retina, its spherical geometry. The geometry of these electrode arrays has the potential to facilitate implantation in the nerve fascicles and to physically stabilize it against displacement after insertion. This report presents a unique combination of variable depth dicing and wet isotropic etching for the fabrication of a variety of convoluted neural array geometries. Also, a method of deinsulating the electrode tips using photoresist as a mask and the limitations of this technique on uniformity are discussed.

19.
Sens Actuators A Phys ; 136(1): 467-474, 2007 May 01.
Article in English | MEDLINE | ID: mdl-18438447

ABSTRACT

Reliable chronic operation of implantable medical devices such as the Utah Electrode Array (UEA) for neural interface requires elimination of transcutaneous wire connections for signal processing, powering and communication of the device. A wireless power source that allows integration with the UEA is therefore necessary. While (rechargeable) micro batteries as well as biological micro fuel cells are yet far from meeting the power density and lifetime requirements of an implantable neural interface device, inductive coupling between two coils is a promising approach to power such a device with highly restricted dimensions. The power receiving coils presented in this paper were designed to maximize the inductance and quality factor of the coils and microfabricated using polymer based thin film technologies. A flexible configuration of stacked thin film coils allows parallel and serial switching, thereby allowing to tune the coil's resonance frequency. The electrical properties of the fabricated coils were characterized and their power transmission performance was investigated in laboratory condition.

SELECTION OF CITATIONS