Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Int J Hyperthermia ; 40(1): 2205071, 2023.
Article in English | MEDLINE | ID: mdl-37127281

ABSTRACT

OBJECTIVES: To compare metal artifacts and evaluation of metal artifact reduction algorithms during probe positioning in computed tomography (CT)-guided microwave ablation (MWA), cryoablation (CRYO), and radiofrequency ablation (RFA). MATERIALS AND METHODS: Using CT guidance, individual MWA, CRYO, and RFA ablation probes were placed into the livers of 15 pigs. CT imaging was then performed to determine the probe's position within the test subject's liver. Filtered back projection (B30f) and iterative reconstructions (I30-1) were both used with and without dedicated iterative metal artifact reduction (iMAR) to generate images from the initial data sets. Semi-automatic segmentation-based quantitative evaluation was conducted to estimate artifact percentage within the liver, while qualitative evaluation of metal artifact extent and overall image quality was performed by two observers using a 5-point Likert scale: 1-none, 2-mild, 3-moderate, 4-severe, 5-non-diagnostic. RESULTS: Among MWA, RFA, and CRYO, compared with non-iMAR in B30f reconstruction, the largest extent of artifact volume percentages were observed for CRYO (11.5-17.9%), followed by MWA (4.7-6.6%) and lastly in RFA (5.5-6.2%). iMAR significantly reduces metal artifacts for CRYO and MWA quantitatively (p = 0.0020; p = 0.0036, respectively) and qualitatively (p = 0.0001, p = 0.0005), but not for RFA. No significant reduction in metal artifact percentage was seen after applying iterative reconstructions (p > 0.05). Noise, contrast-to-noise-ratio, or overall image quality did not differ between probe types, irrespective of the application of iterative reconstruction and iMAR. CONCLUSION: A dedicated metal artifact algorithm may decrease metal artifacts and improves image quality significantly for MWA and CRYO probes. Their application alongside with dedicated metal artifact algorithm should be considered during CT-guided positioning.


Subject(s)
Artifacts , Cryosurgery , Radiofrequency Ablation , Tomography, X-Ray Computed , Tomography, X-Ray Computed/methods , Algorithms , Microwave Imaging , Swine , Animals
2.
Langenbecks Arch Surg ; 406(4): 945-969, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33844077

ABSTRACT

PURPOSE: Postoperative lymphorrhea can occur after different surgical procedures and may prolong the hospital stay due to the need for specific treatment. In this work, the therapeutic significance of the radiological management of postoperative lymphorrhea was assessed and illustrated. METHOD: A standardized search of the literature was performed in PubMed applying the Medical Subject Headings (MeSH) term "lymphangiography." For the review, the inclusion criterion was "studies with original data on Lipiodol-based Conventional Lymphangiography (CL) with subsequent Percutaneous Lymphatic Intervention (PLI)." Different exclusion criteria were defined (e.g., studies with <15 patients). The collected data comprised of clinical background and indications, procedural aspects and types of PLI, and outcomes. In the form of a pictorial essay, each author illustrated a clinical case with CL and/or PLI. RESULTS: Seven studies (corresponding to evidence level 4 [Oxford Centre for Evidence-Based Medicine]) accounting for 196 patients were included in the synthesis and analysis of data. Preceding surgery resulting in postoperative lymphorrhea included different surgical procedures such as extended oncologic surgery or vascular surgery. Central (e.g., chylothorax) and peripheral (e.g., lymphocele) types of postoperative lymphorrhea with a drainage volume of 100-4000 ml/day underwent CL with subsequent PLI. The intervals between "preceding surgery and CL" and between "CL and PLI" were 2-330 days and 0-5 days, respectively. CL was performed before PLI to visualize the lymphatic pathology (e.g., leakage point or inflow lymph ducts), applying fluoroscopy, radiography, and/or computed tomography (CT). In total, seven different types of PLI were identified: (1) thoracic duct (or thoracic inflow lymph duct) embolization, (2) thoracic duct (or thoracic inflow lymph duct) maceration, (3) leakage point direct embolization, (4) inflow lymph node interstitial embolization, (5) inflow lymph duct (other than thoracic) embolization, (6) inflow lymph duct (other than thoracic) maceration, and (7) transvenous retrograde lymph duct embolization. CL-associated and PLI-associated technical success rates were 97-100% and 89-100%, respectively. The clinical success rate of CL and PLI was 73-95%. CL-associated and PLI-associated major complication rates were 0-3% and 0-5%, respectively. The combined CL- and PLI-associated 30-day mortality rate was 0%, and the overall mortality rate was 3% (corresponding to six patients). In the pictorial essay, the spectrum of CL and/or PLI was illustrated. CONCLUSION: The radiological management of postoperative lymphorrhea is feasible, safe, and effective. Standardized radiological treatments embedded in an interdisciplinary concept are a step towards improving outcomes.


Subject(s)
Chylothorax , Embolization, Therapeutic , Lymphocele , Chylothorax/diagnostic imaging , Chylothorax/etiology , Chylothorax/therapy , Ethiodized Oil , Humans , Lymphography , Postoperative Complications/diagnostic imaging , Postoperative Complications/therapy , Thoracic Duct
3.
Eur Radiol Exp ; 4(1): 60, 2020 11 02.
Article in English | MEDLINE | ID: mdl-33135104

ABSTRACT

BACKGROUND: To demonstrate the efficacy of percutaneous computed tomography (CT)-guided afferent lymphatic vessel sclerotherapy (ALVS) in the treatment of postoperative lymphatic leakage (LL) after ineffective therapeutic transpedal lymphangiography (TL). METHODS: A retrospective review in this institute involving 201 patients was conducted from May 2011 to September 2018. Patients diagnosed with postoperative LL undergoing ineffective therapeutical TL before the performance of percutaneous CT-guided ALVS were involved. Technical success and clinical success of TL and ALVS were established. The technical success and efficacy of ALVS in the treatment of postoperative LL after ineffective therapeutic TL were assessed. The clinical success rate of ALVS is also assessed, and the complications are reviewed. RESULTS: In total, nine patients were involved including three patients (33.3%) presented with chylothorax, three patients (33.3%) presented with inguinal lymphatic fistula/lymphocele, and three patients (33.3%) presented with lymphatic fistula in the thigh; 27 ± 18 days (mean ± standard deviation) after surgery, therapeutic TL was successfully performed and showed definite afferent lymphatic vessel and leakage site in all the patients. Due to clinical failure after TLs, the following ALVS was performed with a mean interval of 12 ± 8 days after TL. The technical success rate was 9/9 (100.0%, 95% confidence interval [CI] 63.1-100.0%). An average of 2.7 ± 1.3 mL 95% ethanol as sclerosant agent was injected during the procedure. The clinical success was observed in 8 of the 9 patients (88.9%, 95% CI 51.8-99.7%) with a time between ALVS and the LL cure of 8 ± 6 days. No complications were reported. CONCLUSIONS: Our results showed the role of percutaneous CT-guided ALVS as a safe, feasible, and effective salvage treatment for postoperative LL after ineffective TL.


Subject(s)
Lymphocele/diagnostic imaging , Lymphocele/therapy , Lymphography , Postoperative Complications/diagnostic imaging , Postoperative Complications/therapy , Sclerotherapy/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Radiography, Interventional , Retrospective Studies , Tomography, X-Ray Computed
4.
CVIR Endovasc ; 3(1): 79, 2020 Oct 21.
Article in English | MEDLINE | ID: mdl-33085018

ABSTRACT

In the management of patients with postoperative lymphatic fistula (LF) in different locations, iodized oil-based lymphangiography (LAG) from trans-pedal or intranodal route is an established diagnostic approach with the potential to plan further interventional treatments. However, specific lymphatic interventions are indicated depending on different locations and morphologies of the LF. After a systematic literature review, four types of interventions can be considered, including direct leakage embolization/sclerotherapy (DLE/DLS), percutaneous afferent lymphatic vessel embolization (ALVE), percutaneous afferent lymphatic vessels disruption/sclerotherapy (ALVD/ALVS), and trans-afferent nodal embolization (TNE). In the iodized oil-based LAG, three potential lymphatic targets including confined leakage, definite afferent LVs, and definite closest afferent LNs should be comprehensively assessed. For optimal prospective treatment planning for LF, iodized oil-based post-lymphangiographic computed tomography (post-LAG CT) is a useful complement to the conventional iodized oil-based LAG, which can be performed easily after LAG. This review article summarized the current evidence of the specific lymphatic interventions in patients with postoperative LF and explored the potential benefits of post-LAG CT in the intervention planning from a case series.

5.
PLoS One ; 15(2): e0228578, 2020.
Article in English | MEDLINE | ID: mdl-32040496

ABSTRACT

OBJECTIVES: To compare image quality and metal artifact reduction between virtual monochromatic spectral imaging (VMSI), linearly blended dual-energy (DE) and single-energy (SE) images, each with and without dedicated iterative metal artifact reduction (iMAR) for CT-guided biopsy. MATERIALS AND METHODS: A biopsy trocar was positioned in the liver of six pigs. DE (Sn140/100kVp) and SE (120kVp/200mAs) acquisitions were performed with equivalent dose. From dual-energy datasets DE Q30-3 images and VMSI between 40-180 keV in steps of 20 keV were generated. From SE datasets I30-3 images were reconstructed. All images were reconstructed with and without iMAR. Objective image quality was analyzed applying density measurements at standardized positions (e.g. trocar tip and liver parenchyma adjacent to the trocar tip) and semi-automated threshold based segmentation. Subjective image quality was performed using semi-quantitative scores. Analyses were performed by two observers. RESULTS: At the trocar tip quantitative image analysis revealed significant difference in CT numbers between reconstructions with iMAR compared to reconstructions without iMAR for VMSI at lower keV levels (80 and 100 keV; p = 0.03) and DE (p = 0.03). For liver parenchyma CT numbers were significantly higher in VMSI at high keV compared to low keV (p≤0.01). VMSI at high keV also showed higher CT numbers compared to DE and SE images, though not the level of statistical significance. The best signal-to-noise ratio for VMSI was at 80 keV and comparable to DE and SE. Noise was lowest at 80 keV and lower than in DE and SE. Subjective image quality was best with VMSI at 80 keV regardless of the application of iMAR. iMAR significantly improved image quality at levels of 140 keV and 160 keV. Interreader-agreement was good for quantitative and qualitative analysis. CONCLUSION: iMAR improved image quality in all settings. VMSI with iMAR provided metal artifact reduction and better image quality at 80 keV and thus could improve the accurate positioning in CT-guided needle biopsy. In comparison, DE imaging did not improve image quality compared to SE.


Subject(s)
Biopsy, Needle , Image Processing, Computer-Assisted/methods , Image-Guided Biopsy , Liver/diagnostic imaging , Tomography, X-Ray Computed , Algorithms , Animals , Artifacts , Observer Variation , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection , Signal-To-Noise Ratio , Swine , Vena Cava, Inferior/diagnostic imaging
6.
AJNR Am J Neuroradiol ; 39(9): 1696-1702, 2018 09.
Article in English | MEDLINE | ID: mdl-30093480

ABSTRACT

BACKGROUND AND PURPOSE: The type and composition of an embolic agent have a relevant influence on the performance of endovascular embolization. The aim of this study was to investigate a new version of the liquid embolic agent precipitating hydrophobic injectable liquid (PHIL) with extra-low-viscosity in an in vivo embolization model. MATERIALS AND METHODS: Twenty-four embolization procedures were performed in the porcine rete mirabile. Eight embolizations were performed with PHIL 25% low viscosity, Squid 12, and standard PHIL 25%, respectively. Procedure time, required volume of embolic agent, visibility of the embolic agent, embolization control, embolization extent (ie, penetration of the rete mirabile), amount of reflux, and degree of embolization distal to the rete mirabile were assessed. RESULTS: All embolic agents were adequately visible. The embolization extent was not significantly different among the 3 investigated agents; however, there was a tendency toward a higher embolization extent for PHIL 25% low viscosity (median embolization extent: 88% [PHIL 25% low viscosity]; 65% [Squid 12]; 60% [PHIL 25%]; P = .146). The amount of reflux was significantly lower for the extra-low-viscosity agents PHIL 25% low viscosity and Squid 12 compared with the standard PHIL 25% (median reflux distance: 8 mm [PHIL 25% low viscosity]; 6 mm [Squid 12]; 17 mm [PHIL 25%]; P = .011). All other embolization features did not differ among agents. CONCLUSIONS: PHIL 25% low viscosity is a promising liquid embolic agent for endovascular embolization, featuring effective distal penetration, adequate visibility, a low amount of reflux, and good flow control.


Subject(s)
Embolization, Therapeutic/methods , Polyvinyls , Animals , Female , Models, Animal , Swine , Viscosity
7.
AJNR Am J Neuroradiol ; 38(7): 1377-1382, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28522669

ABSTRACT

BACKGROUND AND PURPOSE: Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model. MATERIALS AND METHODS: An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed. RESULTS: Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 µL; P < .001). CONCLUSIONS: While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization.


Subject(s)
Embolization, Therapeutic/methods , Endovascular Procedures/methods , Intracranial Arteriovenous Malformations/drug therapy , Intracranial Arteriovenous Malformations/surgery , Intracranial Embolism/drug therapy , Intracranial Embolism/surgery , Polyvinyls , Tantalum , Combined Modality Therapy , Dimethyl Sulfoxide/therapeutic use , Drug Combinations , Female , Humans , Injections , Male , Models, Biological , Treatment Outcome
8.
Radiologe ; 57(2): 80-89, 2017 Feb.
Article in German | MEDLINE | ID: mdl-28130580

ABSTRACT

CLINICAL/METHODICAL ISSUE: In the treatment of localized renal cell carcinoma, the lack of randomization in controlled trials on thermal ablation is a major limitation. The latter leads to significant study bias and it ultimately remains unclear whether the improved overall survival in favor of partial nephrectomy can actually be attributed to the treatment method. STANDARD RADIOLOGICAL METHODS: For T1a (≤4 cm) renal cell carcinoma without lymph node and distant metastases, excellent technical and clinical results have been described after imaging-guided radiofrequency ablation and cryoablation. METHODICAL INNOVATIONS: Low major complication rates, preservation of renal function and three-dimensional confirmation of negative ablation margins (A0 ablation) are the advantages of computed tomography (CT)-guided thermal ablation. PERFORMANCE: According to the results of controlled (non-randomized) trials on T1a renal cell cancer, the cancer-specific survival rates are comparable between ablative and surgical techniques. ACHIEVEMENTS: It is high time for prospective randomized controlled trials to define the actual value of percutaneous thermal ablation and partial nephrectomy in the treatment of T1a renal cell carcinoma. PRACTICAL RECOMMENDATIONS: Apart from localized renal cell carcinoma, angiomyolipoma and oncocytoma can be treated by thermal ablation. Transarterial embolization extends the radiological spectrum for the treatment of renal tumors, either as complementary embolization (e. g. before thermal ablation of T1a and T1b renal cell carcinoma), prophylactic embolization (e. g. angiomyolipoma >6 cm), preoperative embolization (e. g. before laparoscopic partial nephrectomy) or palliative embolization (e. g. in patients with symptomatic macrohematuria due to renal cell carcinoma).


Subject(s)
Ablation Techniques/statistics & numerical data , Carcinoma, Renal Cell/epidemiology , Carcinoma, Renal Cell/surgery , Kidney Neoplasms/epidemiology , Kidney Neoplasms/surgery , Nephrectomy/statistics & numerical data , Bias , Carcinoma, Renal Cell/diagnostic imaging , Evidence-Based Medicine , Humans , Kidney Neoplasms/diagnostic imaging , Patient Selection , Prevalence , Prognosis , Risk Factors , Treatment Outcome
9.
Eur J Radiol ; 86: 143-162, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28027741

ABSTRACT

Percutaneous radiofrequency ablation (RFA) for the treatment of stage I renal cell carcinoma has recently gained significant attention as the now available long-term and controlled data demonstrate that RFA can result in disease-free and cancer-specific survival comparable with partial and/or radical nephrectomy. In the non-controlled single center trials, however, the rates of treatment failure vary. Operator experience and ablation technique may explain some of the different outcomes. In the controlled trials, a major limitation is the lack of adequate randomization. In case reports, original series and overview articles, transarterial embolization (TAE) before percutaneous RFA was promising to increase tumor control and to reduce complications. The purpose of this study was to systematically review the literature on TAE as add-on to percutaneous RFA for renal tumors. Specific data regarding technique, tumor and patient characteristics as well as technical, clinical and oncologic outcomes have been analyzed. Additionally, an overview of state-of-the-art embolization materials and the radiological perspective of advanced image-guided tumor ablation (TA) will be discussed. In conclusion, TAE as add-on to percutaneous RFA is feasible and very effective and safe for the treatment of T1a tumors in difficult locations and T1b tumors. Advanced radiological techniques and technologies such as microwave ablation, innovative embolization materials and software-based solutions are now available, or will be available in the near future, to reduce the limitations of bland RFA. Clinical implementation is extremely important for performing image-guided TA as a highly standardized effective procedure even in the most challenging cases of localized renal tumors.


Subject(s)
Carcinoma, Renal Cell/therapy , Catheter Ablation/methods , Kidney Neoplasms/therapy , Carcinoma, Renal Cell/diagnostic imaging , Combined Modality Therapy/methods , Embolization, Therapeutic/methods , Female , Humans , Kidney Neoplasms/diagnostic imaging , Male , Middle Aged , Nephrectomy/methods , Radiography , Surgery, Computer-Assisted , Treatment Failure , Treatment Outcome
11.
Rofo ; 188(8): 746-52, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27388996

ABSTRACT

PURPOSE: The aim of this study was to evaluate the technical feasibility and short-time patency rate of iliac side branch devices based on the authors' institution's experience. MATERIALS AND METHODS: Data of 17 patients (all men) with an aortoiliac aneurysm (median age 72.5 years) who underwent endovascular repair between October 2013 and June 2015 (20 months) at our institution was analyzed retrospectively. Primary endpoint was primary technical success, defined as adequate implantation of the iliac branch device with patency of the hypogastric side branch without the need of further re-interventions within 30 days. Mean follow-up was 8.2 ±â€Š5.4 months. RESULTS: Eighteen iliac side branch devices were implanted with a branch patency of 100 % and a primary technical success rate of 94.4 % (n = 17). Perioperative 30 days mortality was 0 %. The mean diameter of treated abdominal aorta and common iliac artery was 41 ±â€Š14 and 30 ±â€Š8 mm. In one case partial dislocation of the iliac side branch device occurred due to severe kinking of iliac arteries with development of an iliac endoleak type Ib that had to be treated in a second intervention. Three patients (15 %) showed an endoleak type II from the inferior mesenteric artery without the need of re-intervention. After three months one patient suffered from subtotal thrombotic occlusion of the bridging stent that was successfully resolved through intra-arterial fibrinolytic therapy and additional stent graft implantation. CONCLUSION: Summarized, implantation of iliac side branch devices is a feasible technique with favourable short-term results in patients with aortoiliac aneurysm. KEY POINTS: • Implantation of iliac side branch devices is a feasible technique.• Distinguish short-term results of side branch endografting in patients with aortoiliac aneurysm.• Carefully patient selection is necessary to avoid complications and re-interventions. Citation Format: • Maus V, Kurz P, Sommer CM et al. The Use of Iliac Side Branch Devices in Patients with Aortoiliac Aneurysm.. Fortschr Röntgenstr 2016; 188: 746 - 752.


Subject(s)
Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Graft Rejection/etiology , Iliac Aneurysm/diagnosis , Iliac Aneurysm/surgery , Aged , Aged, 80 and over , Feasibility Studies , Female , Graft Survival , Humans , Longitudinal Studies , Male , Middle Aged , Postoperative Complications , Prosthesis Design , Risk Factors , Survival Rate , Treatment Outcome , Vascular Patency
12.
Rofo ; 188(4): 353-8, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26716403

ABSTRACT

UNLABELLED: On February 26th, 2013 the patient law became effective in Germany. Goal of the lawmakers was a most authoritative case law for liability of malpractice and to improve enforcement of the rights of the patients. The following article contains several examples detailing legal situation. By no means should these discourage those persons who treat patients. Rather should they be sensitized to to various aspects of this increasingly important field of law. To identify relevant sources according to judicial standard research was conducted including first- and second selection. Goal was the identification of jurisdiction, literature and other various analyses that all deal with liability of malpractice and patient law within the field of Interventional Radiology--with particular focus on transarterial chemoembolization of the liver and related procedures. In summary, 89 different sources were included and analyzed. The individual who treats a patient is liable for an error in treatment if it causes injury to life, the body or the patient's health. Independent of the error in treatment the individual providing medical care is liable for mistakes made in the context of obtaining informed consent. Prerequisite is the presence of an error made when obtaining informed consent and its causality for the patient's consent for the treatment. Without an effective consent the treatment is considered illegal whether it was free of treatment error or not. The new patient law does not cause material change of the German liablity of malpractice law. KEY POINTS: •On February 26th, 2013 the new patient law came into effect. Materially, there was no fundamental remodeling of the German liability for medical malpractice. •Regarding a physician's liability for medical malpractice two different elements of an offence come into consideration: for one the liability for malpractice and, in turn, liability for errors made during medical consultation in the process of obtaining informed consent. •Forensic practice shows that patients frequently enforce both offences concurrently.


Subject(s)
Informed Consent/legislation & jurisprudence , Liability, Legal , Medical Errors/legislation & jurisprudence , Physicians/legislation & jurisprudence , Radiography, Interventional/standards , Radiology, Interventional/legislation & jurisprudence , Germany , Government Regulation
13.
Urologe A ; 54(2): 219-30, 2015 Feb.
Article in German | MEDLINE | ID: mdl-25690575

ABSTRACT

BACKGROUND: Stage I renal cell carcinoma is a malignancy with a relatively good prognosis. The incidence of all renal cell carcinomas is approximately 9/100,000 persons. There are nearly 15,000 newly diagnosed patients every year (men twice as often as women). TREND: In the last decade, a trend away from radical open resection towards nephron-sparing approaches has been observed. Currently, partial nephrectomy is the surgical gold standard for the treatment of small renal tumors. However, excellent clinical results are obtained using percutaneous radiofrequency ablation (RFA): low complication rates and preservation of the renal function. RESULTS: Primary and secondary technical success rates are 69-100% and 90-100%, respectively. In large series, major complication rates of RFA of 0-14% are reported. A relevant deterioration of renal function after RFA is very rare. The 5-year local recurrence-free survival rates, metastasis-free survival rates, cancer-specific survival rates, and overall survival rates are 88-93, 95-100, 98-100, and 58.3-85%, respectively. In this context, the lack of appropriate long-term data is often cited as a limitation. CONCLUSION: Different meta-analyses come to the conclusion that in case of adequate tumor and patient selection RFA shows oncologic results comparable with surgical resection. Accepted indications for RFA are T1 renal tumors in patients with advanced age, significant comorbidities, reduced renal function, single kidney, and/or no wish for operation. Predictors for the success include tumor size and location as well as operator experience. To define the real efficacy of RFA in the treatment of renal tumors, randomized controlled clinical long-term studies are indicated.


Subject(s)
Carcinoma, Renal Cell/surgery , Catheter Ablation/methods , Kidney Neoplasms/surgery , Minimally Invasive Surgical Procedures/methods , Organ Sparing Treatments/methods , Carcinoma, Renal Cell/diagnosis , Evidence-Based Medicine , Humans , Kidney Neoplasms/diagnosis , Treatment Outcome
14.
Cardiovasc Intervent Radiol ; 38(1): 191-200, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24870700

ABSTRACT

PURPOSE: To evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance. METHODS: After Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann-Whitney test. Histopathological differences were assessed. RESULTS: Mean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm(3), and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm(3), and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone. CONCLUSION: There is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.


Subject(s)
Electroporation/methods , Imaging, Three-Dimensional/methods , Iodized Oil/administration & dosage , Liver/diagnostic imaging , Radiography, Interventional/methods , Tomography, X-Ray Computed/methods , Animals , Models, Animal , Swine
15.
Cardiovasc Intervent Radiol ; 38(2): 442-52, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25167958

ABSTRACT

PURPOSE: This study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA). METHODS: In six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 µm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL). RESULTS: Resulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm(3) for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm(3) for sMWA (P < 0.01, respectively). Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features. CONCLUSIONS: Specific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.


Subject(s)
Catheter Ablation/methods , Imaging, Three-Dimensional/methods , Liver/diagnostic imaging , Tomography, X-Ray Computed/methods , Animals , Contrast Media , Image Enhancement , Liver/ultrastructure , Microwaves , Models, Animal , Sheep
16.
Radiologe ; 54(7): 642-53, 2014 Jul.
Article in German | MEDLINE | ID: mdl-25047521

ABSTRACT

CLINICAL/METHODICAL ISSUE: Evidence-based therapeutic and diagnostic algorithm for hepatocellular carcinoma. STANDARD RADIOLOGICAL METHODS: Ultrasound, computed tomography, magnetic resonance imaging, image-guided percutaneous biopsy, percutaneous thermal ablation and transarterial chemoembolization. METHODICAL INNOVATIONS: Diagnostic and therapy of hepatocellular carcinoma according to the official German interdisciplinary guidelines. PERFORMANCE: The formulation of the German S3 guidelines on diagnosis and therapy of hepatocellular carcinoma was performed under special consideration of quality indicators and standardized quality improvement methods. ACHIEVEMENTS: In 2013 the German S3 guidelines on diagnosis and therapy of hepatocellular carcinoma were published and clinically implemented as part of the nationwide guideline program in oncology of the Deutsche Krebsgesellschaft (German Cancer Society). PRACTICAL RECOMMENDATIONS: The German S3 guidelines on diagnosis and therapy of hepatocellular carcinoma have to be considered as the national gold standard with the goal of optimization of patient care.


Subject(s)
Carcinoma, Hepatocellular/diagnosis , Carcinoma, Hepatocellular/therapy , Hepatectomy/standards , Liver Neoplasms/diagnosis , Liver Neoplasms/therapy , Multimodal Imaging/standards , Practice Guidelines as Topic , Germany , Humans , Liver Neoplasms/epidemiology , Medical Oncology/standards , Radiology/standards
19.
Cardiovasc Intervent Radiol ; 36(3): 731-7, 2013 Jun.
Article in English | MEDLINE | ID: mdl-22926302

ABSTRACT

PURPOSE: This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. METHODS: We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. RESULTS: Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m(2) before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m(2) after RF ablation; not significant). CONCLUSIONS: CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.


Subject(s)
Carcinoma, Renal Cell/surgery , Catheter Ablation/methods , Kidney Neoplasms/surgery , Radiography, Interventional/methods , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/pathology , Female , Humans , Kidney Function Tests , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/pathology , Male , Middle Aged , Postoperative Complications , Retrospective Studies , Treatment Outcome
20.
Radiologe ; 52(1): 44-55, 2012 Jan.
Article in German | MEDLINE | ID: mdl-22249701

ABSTRACT

Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide and represents the main cause of death among European patients with liver cirrhosis. Only 30-40% of patients diagnosed with HCC are candidates for curative treatment options (e.g. surgical resection, liver transplantation or ablation). The remaining majority of patients must undergo local regional and palliative therapies. Transvascular ablation of HCC takes advantage of the fact that the hypervascularized HCC receives most of its blood supply from the hepatic artery. In this context transvascular ablation describes different therapy regimens which can be assigned to four groups: cTACE (conventional transarterial chemoembolization), bland embolization (transarterial embolization TAE), DEB-TACE (TACE with drug-eluting beads, DEB) and SIRT (selective internal radiation therapy, radioembolization). Conventional TACE is the most common type of transvascular ablation and represents a combination of intra-arterial chemotherapy and embolization with occlusion of the arterial blood supply. However, there is no standardized regimen with respect to the chemotherapeutic drug, the embolic agent, the usage of lipiodol and the interval between the TACE procedures. Even the exact course of a cTACE procedure (order of chemotherapy or embolization) is not standardized. It remains unclear whether or not intra-arterial chemotherapy is definitely required as bland embolization using very small, tightly calibrated spherical particles (without intra-arterial administration of a chemotherapeutic drug) shows tumor necrosis comparable to cTACE. For DEB-TACE microparticles loaded with a chemotherapeutic drug combine the advantages of cTACE and bland embolization. Thereby, a continuing chemotherapeutic effect within the tumor might cause a further increase in intratumoral cytotoxicity and at the same time a decrease in systemic toxicity.


Subject(s)
Carcinoma, Hepatocellular/therapy , Embolization, Therapeutic/methods , Embolization, Therapeutic/trends , Hemostatics/administration & dosage , Hepatic Artery , Liver Neoplasms/therapy , Humans , Infusions, Intra-Arterial
SELECTION OF CITATIONS
SEARCH DETAIL
...