1.
Transl Vis Sci Technol ; 11(11): 9, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36374485

ABSTRACT

Purpose: The purpose of this study was to develop and test a programmable closed-loop system for tracking, modulating, and assessing dynamic iris behavior, including in the mid-dilated position. Methods: A programmable closed-loop iris control system was developed by customizing an ANTERION OCT device (Heidelberg Engineering, Heidelberg, Germany). Custom software was developed to store camera and optical coherence tomography (OCT) images, track pupillary diameter (PD), control a light-emitting diode (LED), and modulate ambient lighting to maintain the iris in a dilated, constricted, or mid-dilated position in real-time. Study participants underwent 3 consecutive 65-second scan sessions. Dynamic iris behavior in the form of peak constriction velocity (PCV) and mid-dilated iris activity (MDIA) were calculated and analyzed offline. Results: Among 58 participants, 56 (96.6%) were eligible for analysis based on achieving and maintaining mean PD within ±10% of the calculated mid-dilated PD. Mean participant age was 49.8 ± 18.9 years. Mean PCV was 3.92 ± 0.83 mm/s, and mean MDIA was 0.37 ± 0.15 mm. The mean difference between the calculated and achieved mid-dilated PD was 0.166 ± 0.192 mm. There were significant negative correlations between PCV and age (slope = -0.022, P < 0.001) and MDIA and age (slope = -0.004, P < 0.001). Success rates were lower (69.0%) but relationships between dynamic iris behavior and age were similar based on achieving and maintaining mean PD within ±5% of the calculated mid-dilated PD. Conclusions: A programmable closed-loop iris control system can modulate dynamic iris behavior and maintain the iris in a mid-dilated position. Pupillary constriction velocity and iris activity in the mid-dilated position decrease with age. Translational Relevance: This system can be applied to study dynamic disease processes involving the iris and establish novel biometric measures that could serve as risk factors for acute and chronic primary angle closure glaucoma (PACG).


Subject(s)
Glaucoma, Angle-Closure , Mydriasis , Humans , Adult , Middle Aged , Aged , Intraocular Pressure , Iris/diagnostic imaging , Tomography, Optical Coherence
2.
Eye (Lond) ; 36(1): 119-128, 2022 01.
Article in English | MEDLINE | ID: mdl-33633350

ABSTRACT

BACKGROUND/OBJECTIVES: To evaluate biometric changes throughout the anterior chamber during accommodation and presbyopia using single image acquisition swept-source anterior-segment optical coherence tomography (AS-OCT). SUBJECT/METHODS: Anterior-segment images were obtained using a new swept-source AS-OCT device (ANTERION, Heidelberg Engineering) from healthy volunteers (n = 71) across two centers in this prospective observational case series. In one image acquisition, cornea through posterior lens, including the ciliary muscle on both sides of the right eye, was imaged. Subjects undertook no accommodative effort and -1, -3, and -5 D of target vergence. Two-way repeated measures ANOVA modeling was performed for ciliary muscle measurements, lens parameters, aqueous depth (AD), and pupil diameter (PD). The first ANOVA factor was accommodative stimuli, and the second factor included age and refractive status. RESULTS: Maximum ciliary muscle thickness increased with accommodative stimuli (p < 0.001), while the distance from the scleral spur to the maximal point on the ciliary muscle and posterior ciliary muscle thickness (CMT2) decreased (p < 0.001-0.002). Older individuals showed no accommodative changes for ciliary muscle parameters, lens thickness, lens vault, PD, and AD (p = 0.07-0.32). Younger- and middle-aged eyes showed statistically significant accommodative structural alterations for these endpoints (p < 0.001-0.002), but with different patterns, including early loss of CMT2 contraction in middle-aged eyes. Within the middle-aged group, myopic eyes maintained better capacity for accommodative structural change. CONCLUSIONS: Swept-source AS-OCT demonstrated multiple simultaneous anterior-segment biometric alterations in single acquisition images, including early loss of posterior ciliary muscle function and better maintained capacity for anterior-segment structural change in myopia.


Subject(s)
Lens, Crystalline , Myopia , Accommodation, Ocular , Anterior Chamber/diagnostic imaging , Anterior Eye Segment/diagnostic imaging , Biometry/methods , Humans , Lens, Crystalline/diagnostic imaging , Middle Aged , Myopia/diagnostic imaging , Tomography, Optical Coherence/methods
3.
PLoS One ; 15(10): e0240110, 2020.
Article in English | MEDLINE | ID: mdl-33095821

ABSTRACT

PURPOSE: To assess the effects of age and refractive status on anterior segment anatomical structures, including the ciliary body, using a new swept-source anterior segment optical coherence tomography (AS-OCT) device. METHODS: This prospective observational study included 63 healthy volunteers (mean age: 44.2 years). Images of the anterior segment were obtained using a new swept-source AS-OCT (ANTERION, Heidelberg Engineering GmbH, Heidelberg, Germany) with tracking and image averaging from the right eye of all participants. Repeatability as well as inter- and intra-observer reliability of biometric measurements were evaluated. The impact of image tracking and averaging on ciliary muscle measurements was tested. Univariate and multivariable statistical models were developed to evaluate the relationship of age and refractive status on anterior segment biometric measurements. RESULTS: For all test-retest repeatability and inter- and intra-observer reproducibility of swept-source AS-OCT measurements, high intraclass correlation (ICC) was noted (0.88-1.00). The nasal maximum ciliary muscle thickness (CMTMAX) and distance between scleral spur to the thickest point of the ciliary muscle (SSMAX) were larger than those on the temporal side (p<0.001 and p = 0.006, respectively). Nasal and temporal CMTMAX (p = 0.004 and p<0.001, respectively) and lens thickness (p<0.01) increased with age. Nasal and temporal SSMAX decreased with older age and increasing hyperopia (p = 0.01 and p<0.001, respectively). Image averaging resulted in improved ciliary muscle measurements (p = 0.008 to 0.02). Lens vault increased with older age and increased hyperopia (p<0.01). OCT measurements of the angle decreased with older age and increased hyperopia (p<0.001 to 0.03). Aqueous depth decreased with older age and increased hyperopia (p<0.01). Pupil diameter decreased with older age (p<0.01). CONCLUSIONS: Repeatability and reproducibility of biometric measurements using the ANTERION AS-OCT were excellent. Image averaging improved the accuracy of ciliary muscle measurements. The device produced measurements of biometric parameters that described superficial and deep structures including the ciliary body and full lens thickness from a single image.


Subject(s)
Anterior Eye Segment/diagnostic imaging , Tomography, Optical Coherence/methods , Adult , Age Factors , Aged , Aging , Biometry/methods , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results
4.
Transl Vis Sci Technol ; 9(9): 14, 2020 08.
Article in English | MEDLINE | ID: mdl-32879770

ABSTRACT

Purpose: To assess the repeatability and agreement of ocular biometric parameters measured using the Tomey CASIA SS-1000 and Heidelberg ANTERION anterior segment optical coherence tomography (AS-OCT) devices. Methods: Both eyes of subjects 18 years of age or older were scanned three times with the CASIA and ANTERION under standardized dark lighting. One AS-OCT image along the horizontal (temporal-nasal) meridian was analyzed per eye and per scan. Pupillary diameter (PD) was within 15% for all pairwise comparisons. Anterior chamber depth, lens vault, anterior chamber width, angle opening distance, trabecular iris space area, and scleral spur angle (SSA500) were measured using manufacturer-provided image analysis software. Intraclass correlation (ICC), Wilcoxon signed-rank, and Bland-Altman analyses were performed to assess intradevice repeatability and interdevice agreement of measurements. Results: Thirty-two eyes of 21 subjects were analyzed. There was excellent agreement (ICC >0.98) and no significant difference (P > 0.05) in PD across all comparisons. Intradevice measurement repeatability was excellent for both the CASIA (ICC range 0.93-0.99) and ANTERION (ICC range 0.97-0.99). Interdevice measurement agreement was also excellent (ICC range 0.85-0.96). Measurements within and between devices were similar (P > 0.06) for all parameters except SSA500 (P = 0.03). Linear regression and Bland-Altman plots showed the relationship was consistent across the entire range of measurements. Conclusions: Intradevice measurement repeatability is excellent for the CASIA and ANTERION. Interdevice measurement agreement between the two devices exceeds metrics reported by previous comparison studies. Translational Relevance: Modern swept-source AS-OCT devices produce highly repeatable measurements of ocular biometric parameters that are nearly interchangeable across devices.


Subject(s)
Biometry , Lens, Crystalline , Adolescent , Adult , Anterior Chamber , Humans , Iris , Reproducibility of Results , Tomography, Optical Coherence