Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Open Med (Wars) ; 19(1): 20240943, 2024.
Article in English | MEDLINE | ID: mdl-38584839

ABSTRACT

This study is to probe into the meaning of serum miR-532-5p in nontraumatic osteonecrosis of the femoral head (ONFH), and a molecular mechanism of miR-532-5p in the development of nontraumatic ONFH. This study enrolled 96 patients diagnosed with nontraumatic ONFH and 96 patients with femoral neck fracture. The levels of miR-532-5p, ABL1, MMP-3, MMP-13, and cleaved-caspase3 were determined. Radiographic progression was assessed by ARCO staging system. Visual analog scale (VAS) and Harris hip score (HHS) were employed for evaluation of the symptomatic severity of nontraumatic ONFH. Cell viability and apoptosis in chondrocytes isolated from clinical samples were investigated with CCK-8 and flow cytometry. The levels of lactic dehydrogenase (LDH), superoxide dismutase (SOD), and malondialdehyde (MDA), mitochondrial membrane potential (ΔΨm), and reactive oxygen species (ROS) were determined. miR-532-5p was downregulated in tissues and serum of patients with nontraumatic ONFH, negatively related with ARCO staging and VAS, and positively correlated with HHS. Cell apoptosis, LDH, MDA, and ROS strengthened, while cell viability, ΔΨm, and SOD reduced in chondrocytes of nontraumatic ONFH patients. ABL1 was upregulated in cartilage tissues from nontraumatic ONFH patients. miR-532-5p targeted ABL1, and overexpressed miR-532-5p alleviated nontraumatic ONFH-induced oxidative stress damage of chondrocytes by restraining ABL1. miR-532-5p ameliorated oxidative stress injury in nontraumatic ONFH by inhibiting ABL1.

3.
Phys Med ; 106: 102524, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36641900

ABSTRACT

PURPOSE: In mammography, breast compression is achieved by lowering a compression paddle on the breast. Despite the directive that compression is needed, there is no concrete guideline on its execution. To estimate the degree of compression, current mammography units only provide compression force and breast thickness as parameters. Therefore, radiographers could be induced to mainly determine the level of compression based on compression force and apply the same value to all breast sizes. In this case, smaller breast sizes are exposed to higher pressure. This results in a highly varying perception of discomfort or even pain during the procedure, depending on the breast size. METHODS: To overcome this imbalance, current research results suggest that pressure might be a more qualified parameter for a more uniform compression among all breast sizes. To utilize pressure, the contact area between breast and compression paddle must be determined. In this paper, we present an easy-to-implement prototype enabling a real-time pressure-based measure without the need of direct patient contact. Using an optical camera, the contact area between the breast and the compression paddle is automatically segmented by a deep learning model. RESULTS: The model provides a mean pixel accuracy of 96.7% (SD: 2.3%), mean frequency-weighted intersection over union of 88.5% (SD: 6.3%), and a Dice score of 93.6% (SD: 2.2%). The subsequent pressure display is updated more than five times per second which enables the use in clinical routines to set the compression level. CONCLUSION: This prototype could help guiding to an improved breast compression routine in mammography procedures.


Subject(s)
Breast Neoplasms , Mammography , Humans , Female , Mammography/methods , Pressure , Breast/diagnostic imaging , Pain , Mechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL
...