1.
J Nanosci Nanotechnol ; 18(3): 1782-1786, 2018 Mar 01.
Article in English | MEDLINE | ID: mdl-29448659

ABSTRACT

This study reports a hub-spoke type joint torque sensor involving strain gauges made of multiwalled carbon nanotubes (MWCNT). We developed the novel joint torque sensor for robots by means of MWCNT/epoxy strain sensors (0.8 wt%, gauge factor 2) to overcome the limits of conventional foil strain gauges. Solution mixing process was hired to fabricate a liquid strain sensor that can easily be installed on any complicated surfaces. We painted the MWCNT/epoxy mixing liquid on the hub-spoke type joint torque sensor to form the piezoresistive strain gauges. The painted sensor converted its strain into torque by mean of the installed hub-spoke structure after signal processing. We acquired sufficient torque voltage responses from the painted MWCNT/epoxy strain sensor.

2.
Front Robot AI ; 5: 129, 2018.
Article in English | MEDLINE | ID: mdl-33501007

ABSTRACT

Despite enhancements in the development of robotic systems, the energy economy of today's robots lags far behind that of biological systems. This is in particular critical for untethered legged robot locomotion. To elucidate the current stage of energy efficiency in legged robotic systems, this paper provides an overview on recent advancements in development of such platforms. The covered different perspectives include actuation, leg structure, control and locomotion principles. We review various robotic actuators exploiting compliance in series and in parallel with the drive-train to permit energy recycling during locomotion. We discuss the importance of limb segmentation under efficiency aspects and with respect to design, dynamics analysis and control of legged robots. This paper also reviews a number of control approaches allowing for energy efficient locomotion of robots by exploiting the natural dynamics of the system, and by utilizing optimal control approaches targeting locomotion expenditure. To this end, a set of locomotion principles elaborating on models for energetics, dynamics, and of the systems is studied.

3.
IEEE Trans Syst Man Cybern B Cybern ; 37(2): 341-9, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17416162

ABSTRACT

This paper proposes an energy-based control method of a haptic device with electric brakes. Unsmooth motion is frequently observed in a haptic system using brakes during a wall-following task. Since it is generally known that a haptic system using brakes is passive due to brake's characteristics, its energy behavior has seldom been investigated. However, force distribution at the end effector reveals that the unsmooth motion of a haptic system using brakes represents active behavior of the system in the specific direction. A force control scheme is proposed that computes the gain for smooth motion by considering the energy behavior of a system. Experiments show that smooth wall following is possible with a proposed force control scheme.


Subject(s)
Man-Machine Systems , Models, Theoretical , Physical Stimulation/instrumentation , Touch , Transducers , User-Computer Interface , Computer Simulation , Energy Transfer , Equipment Design , Equipment Failure Analysis , Feedback , Physical Stimulation/methods
4.
Article in English | MEDLINE | ID: mdl-17354936

ABSTRACT

This paper introduces a novel mechanism for surgical robotic systems to generate human arm-like compliant motion. The mechanism is based on the idea of the equilibrium point control hypothesis which claims that multi-joint limb movements are achieved by shifting the limbs' equilibrium positions defined by neuromuscular activity. The equilibrium point control can be implemented on a robot manipulator by installing two actuators at each joint of the manipulator, one to control the joint position, and the other to control the joint stiffness. This double-actuator mechanism allows us to arbitrarily manipulate the stiffness (or impedance) of a robotic manipulator as well as its position. Also, the force at the end-effector can be estimated based on joint stiffness and joint angle changes without using force transducers. A two-link manipulator and a three-link manipulator with the double-actuator units have been developed, and experiments and simulation results show the potential of the proposed approach. By creating the human arm-like behavior, this mechanism can improve the performance of robot manipulators to execute stable and safe movement in surgical environments by using a simple control scheme.


Subject(s)
Biomimetic Materials , Equipment Safety/methods , Robotics/instrumentation , Surgery, Computer-Assisted/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Equipment Safety/instrumentation , Humans , Robotics/methods , Surgery, Computer-Assisted/methods