1.
Phys Med Biol ; 57(9): 2517-38, 2012 May 07.
Article in English | MEDLINE | ID: mdl-22490983

ABSTRACT

Virtual-pinhole PET (VP-PET) imaging is a new technology in which one or more high-resolution detector modules are integrated into a conventional PET scanner with lower resolution detectors. It can locally enhance the spatial resolution and contrast recovery near the add-on detectors, and depending on the configuration, may also increase the sensitivity of the system. This novel scanner geometry makes the reconstruction problem more challenging compared to the reconstruction of data from a stand-alone PET scanner, as new techniques are needed to model and account for the non-standard acquisition. In this paper, we present a general framework for fully 3D modeling of an arbitrary VP-PET insert system. The model components are incorporated into a statistical reconstruction algorithm to estimate an image from the multi-resolution data. For validation, we apply the proposed model and reconstruction approach to one of our custom-built VP-PET systems-a half-ring insert device integrated into a clinical PET/CT scanner. Details regarding the most important implementation issues are provided. We show that the proposed data model is consistent with the measured data, and that our approach can lead to reconstructions with improved spatial resolution and lesion detectability.


Subject(s)
Imaging, Three-Dimensional/methods , Models, Theoretical , Positron-Emission Tomography/methods , Calibration , Humans , Neoplasms/diagnostic imaging , Phantoms, Imaging , Reproducibility of Results , User-Computer Interface
2.
IEEE Trans Nucl Sci ; 58(5): 2148-2154, 2011 Oct.
Article in English | MEDLINE | ID: mdl-25400292

ABSTRACT

In this work we propose a parallel beam approximation for the computation of the detection efficiency of crystals in a PET detector array. In this approximation the detection efficiency of a crystal is estimated using the distance between source and the crystal and the pre-calculated detection cross section of the crystal in a crystal array which is calculated for a uniform parallel beam of gammas. The pre-calculated detection cross sections for a few representative incident angles and gamma energies can be used to create a look-up table to be used in simulation studies or practical implementation of scatter or random correction algorithms. Utilizing the symmetries of the square crystal array, the pre-calculated look-up tables can be relatively small. The detection cross sections can be measured experimentally, calculated analytically or simulated using a Monte Carlo (MC) approach. In this work we used a MC simulation that takes into account the energy windowing, Compton scattering and factors in the "block effect". The parallel beam approximation was validated by a separate MC simulation using point sources located at different positions around a crystal array. Experimentally measured detection efficiencies were compared with Monte Carlo simulated detection efficiencies. Results suggest that the parallel beam approximation provides an efficient and accurate way to compute the crystal detection efficiency, which can be used for estimation of random and scatter coincidences for PET data corrections.

3.
Phys Med Biol ; 55(9): 2573-87, 2010 May 07.
Article in English | MEDLINE | ID: mdl-20393236

ABSTRACT

A PET block detector module using an array of sub-millimeter lutetium oxyorthosilicate (LSO) crystals read out by an array of surface-mount, semiconductor photosensors has been developed. The detector consists of a LSO array, a custom acrylic light guide, a 3 x 3 multi-pixel photon counter (MPPC) array (S10362-11-050P, Hamamatsu Photonics, Japan) and a readout board with a charge division resistor network. The LSO array consists of 100 crystals, each measuring 0.8 x 0.8 x 3 mm(3) and arranged in 0.86 mm pitches. A Monte Carlo simulation was used to aid the design and fabrication of a custom light guide to control distribution of scintillation light over the surface of the MPPC array. The output signals of the nine MPPC are multiplexed by a charge division resistor network to generate four position-encoded analog outputs. Flood image, energy resolution and timing resolution measurements were performed using standard NIM electronics. The linearity of the detector response was investigated using gamma-ray sources of different energies. The 10 x 10 array of 0.8 mm LSO crystals was clearly resolved in the flood image. The average energy resolution and standard deviation were 20.0% full-width at half-maximum (FWHM) and +/-5.0%, respectively, at 511 keV. The timing resolution of a single MPPC coupled to a LSO crystal was found to be 857 ps FWHM, and the value for the central region of detector module was 1182 ps FWHM when +/-10% energy window was applied. The nonlinear response of a single MPPC when used to read out a single LSO was observed among the corner crystals of the proposed detector module. However, the central region of the detector module exhibits significantly less nonlinearity (6.5% for 511 keV). These results demonstrate that (1) a charge-sharing resistor network can effectively multiplex MPPC signals and reduce the number of output signals without significantly degrading the performance of a PET detector and (2) a custom light guide to permit light sharing among multiple MPPC and to diffuse and direct scintillation light can reduce the nonlinearity of the detector response within the limited dynamic range of a typical MPPC. As a result, the proposed PET detector module has the potential to be refined for use in high-resolution PET insert applications.


Subject(s)
Photons , Positron-Emission Tomography/instrumentation , Linear Models , Lutetium/chemistry , Silicates/chemistry , Time Factors
4.
J Nucl Med ; 49(10): 1668-76, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18794253

ABSTRACT

UNLABELLED: A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. METHODS: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a (68)Ge point source, and a calibrated (68)Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A (22)Na point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of (18)F-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of (18)F-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of (18)F-FDG and imaged for 2 h with electrocardiogram gating. RESULTS: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1%. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. CONCLUSION: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.


Subject(s)
Positron-Emission Tomography/instrumentation , Positron-Emission Tomography/methods , Algorithms , Animals , Diagnostic Imaging/instrumentation , Diagnostic Imaging/methods , Electrocardiography/methods , Equipment Design , Fluorine Radioisotopes/pharmacology , Fluorodeoxyglucose F18/pharmacology , Image Processing, Computer-Assisted , Mice , Nuclear Medicine/methods , Phantoms, Imaging
5.
Phys Med Biol ; 49(21): 4961-70, 2004 Nov 07.
Article in English | MEDLINE | ID: mdl-15584530

ABSTRACT

The purpose of this study was to improve the performance of a small gamma camera, utilizing a NaI(Tl) plate and a 5" position sensitive PMT. We attempted to build a NaI(Tl) plate crystal system which retained all its advantages, while at the same time integrating some of the advantages inherent in an array-type scintillation crystal system. Flood images were obtained with a lead hole mask, and position mapping was performed by detecting hole positions in the flood image. Energy calibration was performed using the energy spectra obtained from each hole position. Flood correction was performed using a uniformity correction table containing the relative efficiency of each image element. The spatial resolution was improved about 16% after correction at the centre field of view. Resolution deterioration at the outer field of view (OFOV) was considerably ameliorated, from 6.7 mm to 3.2 mm after correction. The sensitivity at the OFOV was also increased after correction, from 0.7 cps microCi(-1) to 2.0 cps microCi(-1). The correction also improved uniformity, from 5.2% to 2.1%, and linearity, from 0.5 mm to 0 mm. The results of this study indicate that the revised correction method can be employed to considerably improve the performance of a small gamma camera using a NaI(Tl) plate-type crystal. This method also provides high spatial resolution and linearity, like array-type crystals do, while retaining the specific advantages of plate-type crystals.


Subject(s)
Equipment Failure Analysis , Gamma Cameras , Image Enhancement/instrumentation , Positron-Emission Tomography/instrumentation , Radionuclide Imaging/instrumentation , Sodium Iodide/radiation effects , Transducers , Electronics, Medical , Equipment Design , Reproducibility of Results , Sensitivity and Specificity