Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-865381

ABSTRACT

Objective:To investigate the protective effect of a modified orbital decompression on postoperative eye position in thyroid-associated ophthalmopathy (TAO).Methods:A cohort study was performed.One hundred and thirty-six eyes of 96 TAO patients who received orbital decompression in Henan Eye Hospital from July 2008 to July 2018 were enrolled.The patients were divided into two groups according to different operation methods.A depressed bone window was made in the region of orbital apex in the modified orbital decompression group with 100 eyes of 70 patients.A depressed bone window was made in the middle and anterior region of orbit in the traditional orbital decompression group with 36 eyes of 26 patients.The best corrected visual acuity, palpebral fissure, eyeball exophthalmos, strabismus, eyeball position、CT image and postoperative complications were compared.This study was approved by the Ethics Committee of Henan Eye Hospital (No.HNEECKY-2020[07]), and written informed consent was obtained from each subject before surgery.Results:Strabismus was improved in 14 eyes of 10 patients, unchanged in 75 eyes of 52 patients and slightly aggravated in 11 eyes of 8 patients after operation in the modified orbital decompression group.In the traditional orbital decompression group, strabismus was slightly aggravated in 6 eyes of 4 patients, seriously aggravated in 30 eyes of 22 patients after surgery. In the modified orbital decompression group, the eyeball displacement was unchanged in 91 eyes of 64 patients, slightly aggravated in 9 eyes of 6 patients after surgery in the traditional orbital decompression group, the eyeball displacement was slightly aggravated in 15 eyes of 10 patients, seriously aggravated in 21 eyes of 16 patients after surgery.Significant differences were found in the number of eyes with different degree of strabismus and eyeball displacement between the two groups ( Z=-9.634, -10.278, both at P<0.01). The postoperative eyeball exophthalmos values were (14.36±2.03)mm and (14.36±1.03)mm in the modified orbital decompression group and the traditional orbital decompression group, respectively, which were significantly lower than preoperative (20.47±1.92)mm and (20.28±2.03)mm (both at P<0.05). CT imaging showed that the bone window was clear in orbital apex and the compression of optic nerve was relieved postoperatively in the modified orbital decompression group, and the bone window was in anterior part of the orbit and the orbital apex was still crowded in the traditional orbital decompression group.No severe complication was seen during the fellow-up duration in the two groups. Conclusions:Compared with traditional orbital decompression, the modified orbital decompression surgery can reduce the risks of strabismus and eyeball displacement, showing an obvious protective effect on eye position.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-637610

ABSTRACT

Background Orbital cavernous hemangiomas (OCH) is a common benign orbital tumor in adult,and accurate localization and diagnosis before operation supports the significant premise for surgical safety and success of tumor extraction.Objective This study was to research the clinical characteristics,preoperative diagnosis,the selection for different surgical approaches,therapeutic effectiveness and complication prevention of OCH.Methods The clinical data of 117 eyes of 117 patients with OCH who received surgery were retrospectively analyzed.The patients received surgery in Henan Eye Institute,Henan Eye Hospital from January 2011 to December 2014 and followed-up for 3 months to 5 years.The visual acuity,exophthalmos,ocular movement,orbital A/B ultrasound,color Doppler image,CT and MRI were examined before and after surgery.Results The primary clinical manifestations of OCH were gradual exophthalmos and impaired vision.The accordance rate of preoperative diagnosis and pathological diagnosis was 100% in the group of patients.The surgical approachs included conjunctival approach in 52.14% (61/117),lateral orbitectomy in 30.77% (36/117),anterior approach in 16.24% (19/117) and lateral combined with medial approach in 0.85% (1/117).At the end of followed-up,visual acuity was significantly improved in 30.77% (36/117),declined in 8.55% (10/117) and unchanged in 60.68% (71/117).Temporary complications after surgery were pupil dilatation in 14.53% (17/117),emorrhoea in 1.71% (2/117),ocular motility disorders in 16.24% (19/117) and ptosis in 4.27% (5/117).The permanent complications after operation were pupil dilatation in 2.56% (3/117),visual loss in 0.85% (1/117) and permanent abduction imitation in 0.85% (1/117).Conclusions Accurate qualitative and site-specific diagnosis and correct choice of surgeries for OCH depend on clinical and iconographical examinations.Suitable surgical approach and operative skill are helpful to the therapeutic outcome and safety of OCH.

3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-637595

ABSTRACT

Background Orbital blow-out fracture often results in the abnormalities of appearance and function of eye.Because of the special and complex anatomical structure of orbital cavity,it is difficult to design and manufacture the corresponding orbital implants.The computer-aided designing and manufacturing (CADM) technology provides a new approach to orbital implants.However,the clinical value of this method is still under evaluation.Objective This study was to investigate the application and the therapeutic effect of CADM for orbital blow-out fracture.Methods The clinical data of 74 eyes of 74 patients who received surgery for orbital blow-out fracture from July 2006 to July 2012 in Henan Eye Institute,Henan Eye Hospital were retrospectively analyzed.Fiftyeight patients underwent CADM implanted surgery and 16 patients received non-CADM surgery in the same period with matched age,gender and lateral eyes in both groups.The individualized 3D orbital implants were designed and manufactured by the technology of CADM and then were implanted in the bone defects in the CADM group,while the traditional hydroxyapatite artificial bone or high density porous polyethylene material (Medpor) was utilized in the non-CADM group with a fellow-up duration for 22 to 69 months.The best corrected visual acuity (BCVA),eyeball exophthalmos,ocular position,eye movement,diplopia and postoperative complications were evaluated.Results The preoperative BCVA were 0.71±0.37 and 0.69±0.41,and the postoperative BCVA were 0.74±0.38 and 0.72±0.41 in the CADM group and the non-CADM group,respectively,showing an insignificant intergroup difference (Fgroup =0.043,P=0.837),but a significant variation was found over time (Ftime =13.576,P < 0.01).The BCVA was significantly improved after surgery compared with before surgery in both groups (both at P<0.05).No significantdifferences were found in the number of eyes with curative and improved diplopia and eye movement disorders between the two groups during the fellow-up duration (Z =-0.298,P =0.766;Z =-0.548,P =0.584).The preoperative eyeball exophthalmos values were (3.93±0.99)mm and (3.88±0.97)mm and the postoperative ones were (0.91 ±0.67)mmand (1.84±0.80) mm in the CADM group and the non-CADM group,respectively,without significant differencebetween the two groups (Fgroup =3.558,P =0.063).However,the eyeball exophthalmos values after operation wereremarkably lower than those before operation in both groups (both at P<0.05).CT imaging displayed implants fitting well with fracture defect and attached to bone tissue accurately in all of the eyes in the CADM group,but in the nonCADM group,the bulge of implants damaging extraocular muscles or optical nerve was found in 2 eyes.No postoperative complication was seen throughout the fellow-up duration in the CADM group.Conclusions CADM technology for orbital blow-out fracture can reconstruct a 3D bony orbit and effectively repair ocular position and appearance,and furthermore restore eye movement and visual functions.The therapeutic outcome of CADM technology for orbital blow-out fracture is superior to conventional implants.

SELECTION OF CITATIONS
SEARCH DETAIL
...