Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Anal Chim Acta ; 1209: 339854, 2022 May 29.
Article in English | MEDLINE | ID: mdl-35569872

ABSTRACT

The present study demonstrate the first time usage of poly (HPMA-s-GPMA) copolymer for the fabrication of three-component based aptasensor for simple, selective, rapid and label free detection of arsenite (As3+). For this purpose, guanidinium bearing poly (HPMA-s-GPMA) copolymer and MPA-CdTe@CdS quantum dots (QDs) was employed in conjunction with As3+ specific aptamer. This protocol utilizes the quenching phenomena displayed by QDs due to the competitive binding of As3+ ions and cationic copolymer to the aptamer. In particular, the As3+ bind to the specific aptamer, leaving poly (HPMA-s-GPMA) freely available for its electrostatic intercations with QDs, which quenches the fluorescent signal. Contrarily, in the absence of As3+ ions, the aptamer can electrostatically bind to poly (HPMA-s-GPMA); making copolymer inactive to affect the fluorescence signal of the QDs. The efficiency of the proposed fluorescence nanoprobe was further tested using linear calibration curves. The obtained data in the range of 0.01-100 nM showed excellent specificity for As3+ ions with the limit of detection (LOD) of 246.77 pM. Moreover, the "on-off" fluorescent aptasensor is highly selective for As3+ ions in the presence of other interfering metal ions by utilizing As3+ specific aptamer. Furthermore, the reported study showed outstanding applicability in the real-world samples (water, food and soil) containing preservatives, metal ions, minerals, and other moieties. The proposed sensing platform not only exhibits the trace level detection of As3+ ions in cost-effective manner but also opens a pathway for the development of state-of-art device fabrication for on-site detection of arsenic.


Subject(s)
Aptamers, Nucleotide , Arsenic , Biosensing Techniques , Cadmium Compounds , Quantum Dots , Acrylamides , Biosensing Techniques/methods , Limit of Detection , Tellurium
2.
Chem Commun (Camb) ; 56(2): 289-292, 2019 Dec 19.
Article in English | MEDLINE | ID: mdl-31808471

ABSTRACT

A novel biosensor for the rapid detection of lead ions employing the optical properties of AuNPs, a lead-specific aptamer and a cationic peptide has been demonstrated. The limit of detection of the biosensor was 98.7 pM, the lowest so far obtained using colorimetry.


Subject(s)
Aptamers, Nucleotide/chemistry , Colorimetry/methods , Lead/analysis , Metal Nanoparticles/chemistry , Peptides/chemistry , Biosensing Techniques/methods , Color , DNA/chemistry , Gold/chemistry , Limit of Detection , Surface Plasmon Resonance/methods
SELECTION OF CITATIONS
SEARCH DETAIL