Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
ScientificWorldJournal ; 2012: 208135, 2012.
Article in English | MEDLINE | ID: mdl-22545010

ABSTRACT

INTRODUCTION: (18)F-FDG-PET-CT plays an important role in the management of lymphoma postchemotherapy followup. Some centres perform prechemotherapy baseline CT and postchemotherapy PETCT. With a concern of radiation burden, especially in young patients, this study aimed to assess if PETCT radiation dose could be reduced. METHODS: Retrospective analysis of 100 lymphoma patients was performed to record sites of disease on prechemotherapy CT and postchemotherapy PETCT. The potential reduction in radiation and time achieved with PETCT limited to sites of known disease identified on prechemotherapy CT was calculated. RESULTS: No FDG-uptake was seen in 72 cases. FDG uptake at known disease sites was seen in 24. Of the remaining 4, one had clinically significant pathology, a rectal adenocarcinoma. PETCT did not reveal any unexpected sites of lymphoma. Limiting PETCT to sites of known disease would have saved a mean radiation dose of 4 mSv (27.3%), with a mean time of 16 minutes. CONCLUSION: Our study suggests that young patients may benefit from reduced radiation by limiting PETCT to sites of known disease with low risk of missing significant pathology. However, in older patients, with increased incidence of asymptomatic synchronous malignancies, whole-body PETCT is advisable unless prechemotherapy PETCT has been performed.


Subject(s)
Antineoplastic Agents/therapeutic use , Fluorodeoxyglucose F18 , Lymphoma/diagnostic imaging , Multimodal Imaging , Positron-Emission Tomography , Radiopharmaceuticals , Tomography, X-Ray Computed , Follow-Up Studies , Humans , Lymphoma/drug therapy , Lymphoma/pathology , Radiation Dosage
2.
J Infect ; 65(1): 71-9, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22369860

ABSTRACT

AIM: To compare the accuracy of positron emission tomography (PET) using (18)F-FDG (Fluorodeoxyglucose) PET with (111)In-labelled leucocytes scintigraphy (LS) in patients with fever of unknown origin (FUO). METHODS: Twenty-three consecutive patients with FUO were prospectively studied using whole-body LS and PET. Performance of the two modalities for identifying a cause of FUO was evaluated. Final diagnosis was based on biopsy, microbiological tests, clinical and imaging follow-up. RESULTS: Abnormal tracer uptake was seen in 3/23(13%) and 14/23(61%) patients on LS and PET respectively, suggesting a higher sensitivity (p < 0.01) for the latter. All LS positive cases were identified on PET and confirmed as infection. The causes of FUO in the other PET positive patients were: infection (n = 3), vasculitis (n = 3), non-infectious inflammatory conditions (n = 2) and cancer (n = 1). No specific diagnosis was reached in 2 patients. Of 13 patients without a definite diagnosis following PET and LS, 10 made a spontaneous recovery during the follow-up period and no definite cause for FUO was found on investigation. Still's disease, Polymyalgia rheumatica and Chronic fatigue syndrome/Myalgic encephalomyelitis were diagnosed in the remaining three patients during follow-up. The results thus showed an overall sensitivity of 86% for PET and 20% for LS (p < 0.01). The overall specificity for FDG PET was 78% as against 100% for LS. PET had a PPV of 86% and a NPV of 78% whereas LS had a PPV of 100% and a NPV of 40%. CONCLUSION: PET has a higher sensitivity than LS in identifying the aetiology of FUO. PET/PET-CT, where available, should be used as the non-invasive investigation of choice in the assessment of patients with FUO.


Subject(s)
Fever of Unknown Origin/diagnosis , Fluorodeoxyglucose F18/administration & dosage , Indium Radioisotopes/metabolism , Positron-Emission Tomography/methods , Radionuclide Imaging/methods , Radiopharmaceuticals/administration & dosage , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Parvovirus , Prospective Studies , Sensitivity and Specificity , Staining and Labeling/methods
3.
Clin Oncol (R Coll Radiol) ; 24(3): 190-5, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22183080

ABSTRACT

AIMS: To assess the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in patients with squamous cell and undifferentiated cancer neck nodes and no primary site on conventional assessment. MATERIALS AND METHODS: Seventy-eight patients with neck nodal metastases from an unknown primary cancer were studied. PET/CT was carried out in all patients, 1h after FDG injection. RESULTS: Uptake suspicious of an occult primary cancer was found in 46/78 (59.0%) patients. Subsequent investigations confirmed a primary site in the base of the tongue in 14, pharyngeal palatine tonsil in 14, post cricoid in one, lung in one. PET/CT diagnosed primary cancers in 30/78 patients (38.5%); sensitivity, specificity, positive predictive value, negative predictive value: 30/30 (100.0%), 32/48 (66.7%), 30/46 (65.2%), 32/32 (100.0%), respectively. PET/CT detected additional disease in four patients: contralateral nodal disease in two, mediastinal nodal disease in one and liver metastases in one. CONCLUSIONS: FDG PET/CT is of value in the assessment of patients with occult head and neck primary cancers. However, false-positive results remain a limitation of the investigation.


Subject(s)
Carcinoma, Squamous Cell/diagnostic imaging , Fluorodeoxyglucose F18 , Head and Neck Neoplasms/diagnostic imaging , Multimodal Imaging , Positron-Emission Tomography , Radiopharmaceuticals , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/pathology , Female , Follow-Up Studies , Head and Neck Neoplasms/pathology , Humans , Lymphatic Metastasis , Male , Middle Aged , Neoplasm Staging , Prognosis , Retrospective Studies
4.
Radiat Prot Dosimetry ; 150(3): 381-4, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22069232

ABSTRACT

In this study the authors speculate about hypothetical effective-dose (E) reduction through limiting post-chemotherapy PET-CT scanning to lymphoma sites previously identified on pre-treatment CT. E reductions/scan time savings are compared between post-treatment standard and theoretically limited PET-CT scans. The influence of patient age with E savings and associated clinical implication for 100 subjects are discussed. The greatest E theoretical savings of 52 and 32% for the CT contribution and combined PET-CT, respectively, were seen in patients <18 y old using limited scans in this study, with a potential mean time saving of 16 min per patient across the entire cohort. However, the limited PET-CT regime here missed a 1% rate of unexpected cancer that standard PET-CT recorded. The authors recommend performing larger scale multi-centre studies comparing PET-CT pre- and post-chemotherapy to establish full clinical efficacy of this method.


Subject(s)
Lymphoma/diagnostic imaging , Positron-Emission Tomography , Tomography, X-Ray Computed , Adolescent , Adult , Age Factors , Aged , Child , Dose-Response Relationship, Radiation , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Radiopharmaceuticals , Retrospective Studies , Time Factors , Young Adult
5.
Eur J Radiol ; 79(2): 245-9, 2011 Aug.
Article in English | MEDLINE | ID: mdl-20303687

ABSTRACT

Radiography of the excised surgical specimen following wire guided localisation of impalpable breast lesions is standard surgical practice. The aims of the study were to establish the reliability of the breast specimen radiograph (SR) in determining lesion excision and to determine whether the radiographic margin correlated with the histological margin. The clinical, imaging, SR and pathological details of 106 patients with a pre-operative diagnosis of breast cancer were retrospectively reviewed. The reliability of orientation was estimated and the appearance and distance from the mammographic abnormality to each radial margin were measured and correlated with surgical histological findings. The overall accuracy of the specimen radiograph in determining whether the mammographic lesion was present was 99%. The SR could be orientated "very reliably" or "reliably" in 80% of patients however in only 48% of patients did the closest margin on the SR correspond with the same nearest margin at final histology. A maximum measurement of 11 mm or more from the lesion to the specimen edge was associated with a 77% likelihood of having a clear final histological margin (taken as 5mm or more) and if <11 mm a 58% chance of having involved final histological margins. There was however a wide overlap in the results with patients having an apparently wide SR margin but histologically involved margins and vice versa. The SR is reliable at determining whether the target lesion has been removed. The correlation of SR margin orientation and measurement with final histological measurement is however far less reliable.


Subject(s)
Biopsy , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Ductal, Breast/surgery , Adult , Aged , Aged, 80 and over , Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/pathology , Female , Fiducial Markers , Humans , Mammography , Middle Aged , Neoplasm Invasiveness , Reproducibility of Results , Retrospective Studies
6.
J Comput Assist Tomogr ; 23(5): 800-5, 1999.
Article in English | MEDLINE | ID: mdl-10524870

ABSTRACT

PURPOSE: A new nonrigid registration method, designed to reduce the effect of movement artifact in subtraction images from breast MR, is compared with existing rigid and affine registration methods. METHOD: Nonrigid registration was compared with rigid and affine registration methods and unregistered images using 54 gadolinium-enhanced 3D breast MR data sets. Twenty-seven data sets had been previously reported normal, and 27 contained a histologically proven carcinoma. The comparison was based on visual assessment and ranking by two radiologists. RESULTS: When analyzed by two radiologists independently, all three registration methods gave better-quality subtraction images than unregistered images (p < 0.01), but nonrigid registration gave significantly better results than the rigid and affine registration methods (p < 0.01). There was no significant difference between rigid and affine registration methods. CONCLUSION: Nonrigid registration significantly reduces the effects of movement artifact in subtracted contrast-enhanced breast MRI. This may enable better visualization of small tumors and those within a glandular breast.


Subject(s)
Breast/pathology , Magnetic Resonance Imaging/methods , Adult , Aged , Algorithms , Contrast Media , Female , Gadolinium DTPA , Humans , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/statistics & numerical data , Middle Aged , Observer Variation , Statistics, Nonparametric
7.
IEEE Trans Med Imaging ; 18(8): 712-21, 1999 Aug.
Article in English | MEDLINE | ID: mdl-10534053

ABSTRACT

In this paper we present a new approach for the nonrigid registration of contrast-enhanced breast MRI. A hierarchical transformation model of the motion of the breast has been developed. The global motion of the breast is modeled by an affine transformation while the local breast motion is described by a free-form deformation (FFD) based on B-splines. Normalized mutual information is used as a voxel-based similarity measure which is insensitive to intensity changes as a result of the contrast enhancement. Registration is achieved by minimizing a cost function, which represents a combination of the cost associated with the smoothness of the transformation and the cost associated with the image similarity. The algorithm has been applied to the fully automated registration of three-dimensional (3-D) breast MRI in volunteers and patients. In particular, we have compared the results of the proposed nonrigid registration algorithm to those obtained using rigid and affine registration techniques. The results clearly indicate that the nonrigid registration algorithm is much better able to recover the motion and deformation of the breast than rigid or affine registration algorithms.


Subject(s)
Breast/anatomy & histology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Female , Humans
8.
Eur J Vasc Endovasc Surg ; 14(1): 63-8, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9290562

ABSTRACT

The incidence of abdominal aortic aneurysms (AAA) is rising and elective repair is becoming more commonplace. We describe a new, simple midline extraperitoneal approach for AAA repair. It is particularly suitable for patients who have an inflammatory AAA, abdominal adhesions or a horseshoe kidney. This approach provides excellent exposure to the whole aortoiliac system without the need for separate incisions, whilst retaining the potential advantages of the extraperitoneal approach.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Vascular Surgical Procedures/methods , Aortic Aneurysm, Abdominal/complications , Elective Surgical Procedures , Humans , Peritoneum
SELECTION OF CITATIONS
SEARCH DETAIL
...