Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Injury ; 55(3): 111340, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38301490

ABSTRACT

AIMS: After hip arthroplasty surgery, hip precautions are often implemented to minimise the risk of dislocation, although existing evidence does not support their effectiveness. At our institution, we replaced post-operative precautions with a novel pose avoidance protocol in patients undergoing hip hemiarthroplasty for neck of femur fracture. The objectives of our study were to validate this new protocol by assessing the incidence of dislocation before and after its introduction and evaluating its impact on the length of hospital stay. METHODS: Between 20th September 2021 and 19th March 2023, 200 patients underwent 203 hip hemiarthroplasties. Hip precautions were replaced with the new pose avoidance protocol on 20th June 2022. Data were retrospectively collected and included patient demographics, Abbreviated Mental Test Score, American Society of Anaesthesiologists grade, surgical approach, prosthesis, dislocation, and mortality. RESULTS: The incidence of dislocation within 90 days after hip hemiarthroplasty decreased from seven out of 98 cases (7.1%) before 20th June 2022 to one out of 105 cases (1.0%), p-value 0.030. However, there was no significant difference in the length of stay, with a median (interquartile range) of 19 (10 - 29) days before 20th June 2022, and 16 (11 - 22) days thereafter, p-value 0.242. A multivariate logistic regression confirmed the pose avoidance protocol and the anterolateral approach to be independent negative predictors of dislocation, p-value 0.030 (Odds Ratio [OR] 0.077) and p-value 0.005 (OR 0.022), respectively. CONCLUSIONS: Hip precautions are unnecessary and potentially detrimental to patient outcomes following hemiarthroplasty. Replacing these precautions with our new pose avoidance protocol may have led to a significant reduction in dislocation rates and saved on the cost of adaptive equipment. We advocate for the anterolateral over the posterior approach in hip hemiarthroplasty to further mitigate the risk of dislocation. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hemiarthroplasty , Hip Dislocation , Joint Dislocations , Humans , Hemiarthroplasty/adverse effects , Hemiarthroplasty/methods , Retrospective Studies , Femoral Neck Fractures/surgery , Femoral Neck Fractures/complications , Joint Dislocations/surgery , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Dislocation/surgery
2.
Knee Surg Sports Traumatol Arthrosc ; 26(9): 2797-2803, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29204862

ABSTRACT

PURPOSE: The purpose of the study was to investigate the theoretical isometric point based of the curve of the femoral groove and relating it to the origin of the MPFL femoral tunnel on lateral radiograph by comparing a patellar instability cohort with a control cohort. METHODS: From a Patellar Instability database the radiographs of 40 consecutive patients were analysed to define Schöttle's point, and the arc of the circle of the trochlear groove. A comparison population of 20 radiographs from comparable patients with tibiofemoral joint disorders was used as a control. The distance from Schöttle's point to the most anterior part of the groove (extension) was also compared to the distance to the distal end of the roof of the notch (flexion). RESULTS: The trochlea was circular in the controls but not the Patellofemoral Instability cohort where trochlear dysplasia is usually present. The difference between the extension and flexion length was a mean of - 2.0 ± 0.5 mm in the controls and + 6.0 ± 0.5 mm in the patellofemoral cohort. In neither cohort did the centre of the circle correspond to Schöttle's point. The extension distance correlated with the boss height. CONCLUSIONS: The dysplastic trochlea is not circular and the centre of the best matched circle was different to the control trochleae which were circular. The circle centres did not correlate with Schöttle's point for either cohort, and was more proximal in the Patellofemoral Instability cohort. CLINICAL RELEVANCE: For the MPFL to have equal tension throughout flexion within the groove, the length should not change. In normal knees the MPFL does not behave isometrically. The change in length, as measured from Schöttle's point to the trochlea, was greater for patellofemoral instability patients explaining why an isolated MPFL reconstruction in the presence of severe trochlear dysplasia risks poor outcomes. Level of evidence III.


Subject(s)
Femur/diagnostic imaging , Joint Instability/diagnostic imaging , Patellofemoral Joint/diagnostic imaging , Adolescent , Adult , Case-Control Studies , Cohort Studies , Female , Humans , Ligaments, Articular/diagnostic imaging , Male , Middle Aged , Patellar Dislocation/diagnostic imaging , Radiography , Range of Motion, Articular , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...