Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(5)2024 Feb 24.
Article in English | MEDLINE | ID: mdl-38475008

ABSTRACT

Sign language serves as the primary mode of communication for the deaf community. With technological advancements, it is crucial to develop systems capable of enhancing communication between deaf and hearing individuals. This paper reviews recent state-of-the-art methods in sign language recognition, translation, and production. Additionally, we introduce a rule-based system, called ruLSE, for generating synthetic datasets in Spanish Sign Language. To check the usefulness of these datasets, we conduct experiments with two state-of-the-art models based on Transformers, MarianMT and Transformer-STMC. In general, we observe that the former achieves better results (+3.7 points in the BLEU-4 metric) although the latter is up to four times faster. Furthermore, the use of pre-trained word embeddings in Spanish enhances results. The rule-based system demonstrates superior performance and efficiency compared to Transformer models in Sign Language Production tasks. Lastly, we contribute to the state of the art by releasing the generated synthetic dataset in Spanish named synLSE.


Subject(s)
Deep Learning , Humans , Sign Language , Hearing , Communication
2.
Sensors (Basel) ; 15(3): 5163-96, 2015 Mar 03.
Article in English | MEDLINE | ID: mdl-25742171

ABSTRACT

An innovative approach to physical activity recognition based on the use of discrete variables obtained from accelerometer sensors is presented. The system first performs a discretization process for each variable, which allows efficient recognition of activities performed by users using as little energy as possible. To this end, an innovative discretization and classification technique is presented based on the χ2 distribution. Furthermore, the entire recognition process is executed on the smartphone, which determines not only the activity performed, but also the frequency at which it is carried out. These techniques and the new classification system presented reduce energy consumption caused by the activity monitoring system. The energy saved increases smartphone usage time to more than 27 h without recharging while maintaining accuracy.


Subject(s)
Cell Phone , Monitoring, Physiologic , Motor Activity/physiology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...