Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 11(8)2021 Jul 26.
Article in English | MEDLINE | ID: mdl-34441270

ABSTRACT

INTRODUCTION: Our aim was to assess the value of adding standard biopsy to targeted biopsy in cases of suspicious multiparametric magnetic resonance imaging (mp-MRI) and also to evaluate when a biopsy of a PI-RADS 3 lesion could be avoided. METHODS: A retrospective study of patients who underwent targeted biopsy plus standard systematic biopsy between 2016-2019 was performed. All the 1.5 T magnetic resonance images were evaluated according to PI-RADSv.2. An analysis focusing on the clinical scenario, lesion location, and PI-RADS score was performed. RESULTS: A total of 483 biopsies were evaluated. The mean age was 65 years, with a PSA density of 0.12 ng/mL/cc. One-hundred and two mp-MRIs were categorized as PI-RADS-3. Standard biopsy was most helpful in detecting clinically significant prostate cancer (csPCa) in patients in the active surveillance (AS) cohort (increasing the detection rate 12.2%), and in peripheral lesions (6.5%). Adding standard biopsy showed no increase in the detection rate for csPCa in patients with PI-RADS-5 lesions. Considering targeted biopsy in patients with PI-RADS 3 lesions, a higher detection rate was shown in biopsy-naïve patients versus AS and in patients with a previous negative biopsy (p = 0.002). Furthermore, in these patients, the highest rate of csPCa detection was in anterior lesions [42.9% (p = 0.067)]. CONCLUSIONS: Our results suggest that standard biopsy could be safely omitted in patients with anterior lesions and in those with PI-RADS-5 lesions. Targeted biopsy for PI-RADS-3 lesions would be less effective in peripheral lesions with a previous negative biopsy.

2.
Dalton Trans ; 49(6): 1822-1829, 2020 Feb 11.
Article in English | MEDLINE | ID: mdl-31961353

ABSTRACT

Combination of the polyimide 6FDA-mPD (6FDA = 4,4'-hexafluoroisopropylidene diphthalic anhydride and mPD = m-phenylenediamine) and crystallites of the metal-organic frameworks (MOFs) MIL-101(Cr) or MOF-199 (HKUST-1, Cu-BTC) produces mixed-matrix membranes (MMMs) with excellent dispersion and compatibility of the MOF particles within the polymer matrix. Permeation tests of a binary CO2/CH4 (50/50) gas mixture showed a remarkable increase of CO2 permeabilities for MIL-101(Cr)@6FDA-mPD and significantly higher selectivities for MOF-199@6FDA-mPD. The CO2 permeability increased from 10 (neat polymer) to 50 Barrer for the 24 wt% MIL-101(Cr)@6FDA-mPD membrane (with essentially constant selectivity) due to the high pore volume of MIL-101(Cr). The CO2/CH4 selectivity increased from 54 to 89 from the neat 6FDA-mPD polymer to the 24 wt% MOF-199@6FDA-mPD membrane, apparently due to the high CO2 adsorption capacity of MOF-199.

3.
Macromol Rapid Commun ; 41(2): e1900572, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31846137

ABSTRACT

Microporous polymer nanosheets with thicknesses in the range 3-5 nm and with high apparent surface area (Brunauer-Emmett-Teller surface area 940 m2 g-1 ) are formed when the effectively bifunctional (tetrafluoro) monomer used in the preparation of the prototypical polymer of intrinsic microporosity PIM-1 is replaced with an effectively tetrafunctional (octafluoro) monomer to give a tightly crosslinked network structure. When employed as a filler in mixed-matrix membranes based on PIM-1, a low loading of 0.5 wt% network-PIM-1 nanosheets gives rise to enhanced CO2 permeability and CO2 /CH4 selectivity, compared to pure PIM-1.


Subject(s)
Membranes, Artificial , Nanostructures/chemistry , Polymers/chemistry , Carbon Dioxide/chemistry , Gases/chemistry , Methane/chemistry , Nanostructures/ultrastructure , Permeability , Porosity
4.
Front Chem ; 7: 693, 2019.
Article in English | MEDLINE | ID: mdl-31709226

ABSTRACT

Covalent triazine framework CTF-1 and polysulfone (PSF) are used to form mixed-matrix membranes (MMMs) with 8, 16, and 24 wt% of the porous filler material CTF-1. Studies on permeability and selectivity are carried out concerning the gases O2, N2, CO2, and CH4. CO2 permeability of the synthesized MMMs increases by 5.4 Barrer in comparison to the pure PSF membrane. The selectivity remains unchanged for O2/N2 and CO2/CH4 but was found to be increased for CO2/N2. Further, comparisons to theoretical models for permeability prediction yield a permeability for CTF-1 which is about six times higher than the permeability of PSF. The inverse of the sum of the free fractional volumes (FFV) of the polymer and the filler correlate linearly to the logarithm of the permeabilities of the gases which conversely indicates that the porosity of the filler contributes to the gas transport through the membrane.

5.
ACS Appl Mater Interfaces ; 8(25): 16486-92, 2016 Jun 29.
Article in English | MEDLINE | ID: mdl-27268426

ABSTRACT

This work reports the fabrication and characterization of Langmuir-Blodgett films of nanoparticles (size 51 ± 10 nm) of the metal organic framework MIL-101(Cr). LB film characterization by SEM, UV-vis, GIXRD, and QCM has shown that the addition of 1 wt % of behenic acid to MOF dispersion allows obtaining dense monolayers at the air-water interface that can be deposited onto solid substrates of different nature with transfer ratios close to 1. Moreover, a QCM-based setup has been built and used for the first time to measure CO2 adsorption isotherms at 303 K on MOF LB films, proving that LB films with MOF masses between 1.2 (1 layer) and 2.3 (2 layers) µg can be used to obtain accurate adsorption values at 100 kPa, similar to those obtained by conventional adsorption methods that require much larger MOF quantities (tens of milligrams).

6.
Adv Funct Mater ; 26(18): 3154-3163, 2016 May 10.
Article in English | MEDLINE | ID: mdl-29200991

ABSTRACT

Mixed-matrix membranes (MMMs) comprising NH2-MIL-53(Al) and Matrimid® or 6FDA-DAM have been investigated. The MOF loading has been varied between 5 and 20 wt%, while NH2-MIL-53(Al) with three different morphologies: nanoparticles, nanorods and microneedles have been dispersed in Matrimid®. The synthesized membranes have been tested in the separation of CO2 from CH4 in an equimolar mixture. At 3 bar and 298 K for 8 wt% MOF loading, incorporation of NH2-MIL-53(Al) nanoparticles leads to the largest improvement compared to nanorods and microneedles. The incorporation of the best performing filler, i.e. NH2-MIL-53(Al) nanoparticles, to the highly permeable 6FDA-DAM has a larger effect, and the CO2 permeability increased up to 85 % with slightly lower selectivities for 20 wt% MOF loading. Specifically, these membranes have a permeability of 660 Barrer with CO2/CH4 separation factor of 28, leading to a performance very close to the Robeson limit of 2008. Furthermore, a new non-destructive technique based on Raman spectroscopy mapping is introduced to assess the homogeneity of the filler dispersion in the polymer matrix. The MOF contribution can be calculated by modelling the spectra. The determined homogeneity of the MOF filler distribution in the polymer is confirmed by FIB-SEM analysis.

7.
J Am Chem Soc ; 135(40): 15201-8, 2013 Oct 09.
Article in English | MEDLINE | ID: mdl-24044635

ABSTRACT

Thin-film nanocomposite membranes containing a range of 50-150 nm metal-organic framework (MOF) nanoparticles [ZIF-8, MIL-53(Al), NH2-MIL-53(Al) and MIL-101(Cr)] in a polyamide (PA) thin film layer were synthesized via in situ interfacial polymerization on top of cross-linked polyimide porous supports. MOF nanoparticles were homogeneously dispersed in the organic phase containing trimesoyl chloride prior to the interfacial reaction, and their subsequent presence in the PA layer formed was inferred by a combination of contact angle measurements, FT-IR spectroscopy, SEM, EDX, XPS, and TEM. Membrane performance in organic solvent nanofiltration was evaluated on the basis of methanol (MeOH) and tetrahydrofuran (THF) permeances and rejection of styrene oligomers (PS). The effect of different post-treatments and MOF loadings on the membrane performance was also investigated. MeOH and THF permeance increased when MOFs were embedded into the PA layer, whereas the rejection remained higher than 90% (molecular weight cutoff of less than 232 and 295 g·mol(-1) for MeOH and THF, respectively) in all membranes. Moreover, permeance enhancement increased with increasing pore size and porosity of the MOF used as filler. The incorporation of nanosized MIL-101(Cr), with the largest pore size of 3.4 nm, led to an exceptional increase in permeance, from 1.5 to 3.9 and from 1.7 to 11.1 L·m(-2)·h(-1)·bar(-1) for MeOH/PS and THF/PS, respectively.

8.
Chem Commun (Camb) ; 48(75): 9388-90, 2012 Sep 28.
Article in English | MEDLINE | ID: mdl-22892418

ABSTRACT

Silica-(ZIF-8) core-shell spheres with tuneable ordered meso-microporosity have been synthesized, showing that the hydrophobic micropore ZIF-8 shell controls the access of guest molecules into the hydrophilic silica mesoporous structure.

SELECTION OF CITATIONS
SEARCH DETAIL
...