Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 181: 19-23, 2018 May 01.
Article in English | MEDLINE | ID: mdl-29426499

ABSTRACT

The determination of 1-chloro-2,4-dinitrobenzene (CDNB) was used as a proof-of-concept to a simple analytical practical configuration applying magnetic molecularly imprinted particles (mag-MIPs). Mag-MIPs were captured from an emulsion by a home-made magneto-sensor (where a small magnet was entrapped by a graphite-epoxy composite) and then, this sensor, was transferred to the solution containing the analyte, where, after binding to the mag-MIPs, the analyte was directly analysed using differential pulse voltammetry (DPV) since the magneto-sensor acted as the working electrode. After optimization, a detection limit of 6.0 µmol L-1 with a RSD of 2.7% was achieved along with suitable recoveries and selectivity. This methodology offers a different approach for electroanalytical methodologies using mag-MIPs.

2.
Biosens Bioelectron ; 77: 978-85, 2016 Mar 15.
Article in English | MEDLINE | ID: mdl-26544873

ABSTRACT

A nano-molecularly imprinted polymer (N-MIP) assembled on a screen-printed electrode for the cardiac troponin T (cTnT) was developed. The biomimetic surface was obtained by a co-polymer matrix assembled on the reduced graphene oxide (RGO) electrode surface. The cTnT active sites were engineered using pyrrole and carboxylated pyrrole that was one-step electropolymerized jointly with cTnT by cyclic voltammetry. The stepwise preparation of the biomimetic surface was characterized by cyclic and differential pulse voltammetries using the ferrocyanide/ferricyanide as redox probe. Structural and morphological characterization was also performed. The optimal relation of pyrrole and pyrrole-3-acid carboxylic to perform the cTnT biomimetic nanosurface was obtained at 1:5 ratio. The analytical performance of cTnT N-MIP performed by differential pulse voltammetry showed a linear range from 0.01 to 0.1 ngmL(-1) (r=0.995, p«0.01), with a very low limit of detection (0.006 ngmL(-1)). The synergic effect of conductive polymer and graphene forming 3D structures of reactive sites resulted in a N-MIP with excellent affinity to cTnT binding (KD=7.3 10(-13) molL(-1)). The N-MIP proposed is based on a simple method of antibody obtaining with a large potential for point-of-care testing applications.


Subject(s)
Conductometry/instrumentation , Electrodes , Graphite/chemistry , Immunoassay/instrumentation , Molecular Imprinting/methods , Troponin T/blood , Electric Conductivity , Electroplating/methods , Equipment Design , Equipment Failure Analysis , Humans , Photography/methods , Reproducibility of Results , Sensitivity and Specificity
3.
Biosens Bioelectron ; 26(3): 1062-7, 2010 Nov 15.
Article in English | MEDLINE | ID: mdl-20863683

ABSTRACT

Screen-printed electrodes (SPE) have been widely used in the design of disposable sensors bringing advances in the use of electrochemical immunosensors for in field-clinical analysis. In this work, streptavidin polystyrene microspheres were incorporated to the electrode surface of SPEs in order to increase the analytical response of the cardiac troponin T (cTnT), a specific biomarker for the acute myocardial infarction diagnosis. The precise calculation of the stoichiometric streptavidin-biotin ratio [1:4] allowed the increase of sensitivity and stability of the immunosensor response to the cTnT analyte. The surface of the immunosensor was characterized by scanning electron microscopy and cyclic voltammetry. It was observed that the use of streptavidin microspheres significantly increased the analytical sensitivity of the electrode in 8.5 times, showing a curve with a linear response range between 0.1 and 10 ngmL(-1) of cTnT and a detection limit of 0.2 ngmL(-1). The proposed SPE showed ease preparation and high sensitivity allowing the detection of cTnT in the range of clinical levels. The new device coupled with a portable electrochemical analyzer shows great promise for point-of-care quantitative testing of necrosis cardiac proteins.


Subject(s)
Biosensing Techniques/instrumentation , Troponin T/analysis , Antibodies, Immobilized , Antibodies, Monoclonal , Biomarkers/blood , Biosensing Techniques/methods , Biosensing Techniques/statistics & numerical data , Electrochemical Techniques , Humans , Immunoassay , Microscopy, Electron, Scanning , Microspheres , Myocardial Infarction/blood , Myocardial Infarction/diagnosis , Reproducibility of Results , Streptavidin , Troponin T/blood , Troponin T/immunology
SELECTION OF CITATIONS
SEARCH DETAIL
...