1.
Sci Rep ; 13(1): 16624, 2023 10 03.
Article in English | MEDLINE | ID: mdl-37789124

ABSTRACT

A minimal necessary condition for preclinical studies to contribute to risk assessments of e-cigarettes (ECs) is the ability to expose laboratory animals to an appropriate dosage of aerosols. In this study, we examined the fulfilment of this essential consistency condition for the ECX-Joyetech E-Vic Mini (ECX), a piece of computerized exposure equipment manufactured by SCIREQ, which has been employed by numerous in vivo testing. We began by calibrating the customary Evic VTC mini device mod and the 4 coils available, reproducing in the laboratory the operation of the ECX in the power-control and temperature-control modes, using puffing parameters recommended by its documentation. We then conducted the following tests for each coil: (1) verifying whether the generated aerosols satisfy an optimal operational regime, free from overheating, as determined by a linear relation between the mass of vaporized e-liquid vs. supplied power and (2) obtaining the mean yields of aldehydes for each of the tested power settings and coils. The results of these tests show that, under the main conditions used in in vivo testing, the ECX equipment fails to comply with these consistency requirements, especially for coils with low subohm resistance, a shortcoming that can be corrected by applying much larger airflows for these coils. Therefore, the outcomes of preclinical studies using the ECX equipment should be examined with great scepticism and subjected to further testing.


Subject(s)
Electronic Nicotine Delivery Systems , Tobacco Products , Animals , Aerosols/chemistry , Lung , Aldehydes
3.
Toxics ; 10(12)2022 Nov 22.
Article in English | MEDLINE | ID: mdl-36548547

ABSTRACT

We review the literature on laboratory studies quantifying the production of potentially toxic organic byproducts (carbonyls, carbon monoxide, free radicals and some nontargeted compounds) in e-cigarette (EC) aerosol emissions, focusing on the consistency between their experimental design and a realistic usage of the devices, as determined by the power ranges of an optimal regime fulfilling a thermodynamically efficient process of aerosol generation that avoids overheating and "dry puffs". The majority of the reviewed studies failed in various degrees to comply with this consistency criterion or supplied insufficient information to verify it. Consequently, most of the experimental outcomes and risk assessments are either partially or totally unreliable and/or of various degrees of questionable relevance to end users. Studies testing the devices under reasonable approximation to realistic conditions detected levels of all organic byproducts that are either negligible or orders of magnitude lower than in tobacco smoke. Our review reinforces the pressing need to update and improve current laboratory standards by an appropriate selection of testing parameters and the logistical incorporation of end users in the experimental design.

4.
Toxics ; 10(9)2022 Aug 29.
Article in English | MEDLINE | ID: mdl-36136475

ABSTRACT

The inhalation of metallic compounds in e-cigarette (EC) aerosol emissions presents legitimate concerns of potential harms for users. We provide a critical review of laboratory studies published after 2017 on metal contents in EC aerosol, focusing on the consistency between their experimental design, real life device usage and appropriate evaluation of exposure risks. All experiments reporting levels above toxicological markers for some metals (e.g., nickel, lead, copper, manganese) exhibited the following experimental flaws: (i) high powered sub-ohm tank devices tested by means of puffing protocols whose airflows and puff volumes are conceived and appropriate for low powered devices; this testing necessarily involves overheating conditions that favor the production of toxicants and generate aerosols that are likely repellent to human users; (ii) miscalculation of exposure levels from experimental outcomes; (iii) pods and tank devices acquired months and years before the experiments, so that corrosion effects cannot be ruled out; (iv) failure to disclose important information on the characteristics of pods and tank devices, on the experimental methodology and on the resulting outcomes, thus hindering the interpretation of results and the possibility of replication. In general, low powered devices tested without these shortcomings produced metal exposure levels well below strict reference toxicological markers. We believe this review provides useful guidelines for a more objective risk assessment of EC aerosol emissions and signals the necessity to upgrade current laboratory testing standards.

5.
Article in English | MEDLINE | ID: mdl-31783619

ABSTRACT

Most recent studies on electronic cigarettes (e-cigs) have been carried out using vaping regimens consistent with mouth-to-lung inhalation (MTL) and not with direct-to-lung (DTL) inhalation. This paper aimed to characterizing the influence of inhalation properties (puff duration, puff volume, airflow rate) on the mass of vaporized e-liquid (MVE). Because the literature on DTL is non-existent, an intense vaping regimen consistent with DTL inhalation (i.e., puff volume = 500 mL) was defined. The use of a low or standard (ISO/DIS 20768) regimen and the proposed intense vaping regimen were first compared using the Cubis 1 Ω atomizer on a large power range, and then by using two atomizers below 1 Ω and two others above 1 Ω on their respective power ranges. An analysis of the e-cig efficiency on the e-liquid vaporization was proposed and calculated for each MVE. The intense vaping regimen allowed a broader power range in optimal heating conditions. MVE linearly increased with the supplied power, up to over-heating conditions at higher powers. Moreover, the e-cigs' efficiencies were higher when low-resistance atomizers were tested at high powers. All these results highlighted that the generated vapor might be better evacuated when an intense vaping regimen is used, and illustrate the obvious need to define a suitable standardized vaping regimen consistent with DTL inhalation.


Subject(s)
Electronic Nicotine Delivery Systems , Nicotine/chemistry , Vaping , Aerosols , Electronic Nicotine Delivery Systems/standards , Gases , Heating , Humans , Models, Theoretical , Nebulizers and Vaporizers , Volatilization
6.
Article in English | MEDLINE | ID: mdl-31248048

ABSTRACT

This work focuses on an experimental study of the influence of e-liquid composition on the mass of vaporized e-liquid after standardized emission generation using a U-SAV (Universal System for Analysis of Vaping) vaping machine. All the experiments were based on the use of a Cubis 1Ω clearomiser and on the standard protocol for electronic cigarettes emission generation. Currently, there is no standardized method available to calibrate the emission generations of electronic cigarettes. Since the e-liquid compositions are not always known, we propose a simple, practical, effective, and fast method of emission generation calibration. Therefore, this paper examines a major issue in this new and constantly evolving field, allowing the validation of the emission generation results. To our knowledge, this method is a novelty in our discipline and could be easily developed in laboratories. Pure propylene-glycol, glycerol, ethanol, and water and their mixtures (20 e-liquids) were tested as reference materials, allowing an e-liquids benchmarking and the characterization of 800 commercial e-liquids (with known and unknown compositions) at a fixed power and for one inhalation profile (3 s puff duration and 55 mL of puff volume). The influence of ethanol and/or water addition in the e-liquid was characterized.


Subject(s)
Electronic Nicotine Delivery Systems , Calibration , Ethanol/analysis , Glycerol/analysis , Propylene Glycol/analysis , Reference Values , Water/analysis
7.
Article in English | MEDLINE | ID: mdl-29036888

ABSTRACT

The accurate study of aerosol composition and nicotine release by electronic cigarettes is a major issue. In order to fully and correctly characterize aerosol, emission generation has to be completely mastered. This study describes an original vaping machine named Universal System for Analysis of Vaping (U-SAV), dedicated to vaping product study, enabling the control and real-time monitoring of applied flow rate and power. Repeatability and stability of the machine are demonstrated on flow rate, power regulation and e-liquid consumption. The emission protocol used to characterize the vaping machine is based on the AFNOR-XP-D90-300-3 standard (15 W power, 1 Ω atomizer resistance, 100 puffs collected per session, 1.1 L/min airflow rate). Each of the parameters has been verified with two standardized liquids by studying mass variations, power regulation and flow rate stability. U-SAV presents the required and necessary stability for the full control of emission generation. The U-SAV is recognised by the French association for standardization (AFNOR), European Committee for Standardization (CEN) and International Standards Organisation (ISO) as a vaping machine. It can be used to highlight the influence of the e-liquid composition, user behaviour and nature of the device, on the e-liquid consumption and aerosol composition.


Subject(s)
Aerosols , Electronic Nicotine Delivery Systems , Vaping , Nebulizers and Vaporizers