Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Reprod Fertil Dev ; 32(8): 763-773, 2020 May.
Article in English | MEDLINE | ID: mdl-32389177

ABSTRACT

According to the developmental origins of health and disease (DOHaD) hypothesis, changes in the maternal environment are known to reprogram the metabolic response of offspring. Known for its redox modulation, caloric restriction extends the lifespan of some species, which contributes to diminished cellular damage. Little is known about the effects of gestational caloric restriction, in terms of antioxidant parameters and molecular mechanisms of action, on the reproductive organs of offspring. This study assessed the effects of moderate (20%) caloric restriction on redox status parameters, molecular expression of sirtuin (SIRT) 1 and SIRT3 and histopathological markers in the ovaries and testes of adult rats that were subjected to gestational caloric restriction. Although enzyme activity was increased, ovaries from female pups contained high levels of oxidants, whereas testes from male pups had decreased antioxidant enzyme defences, as evidenced by diminished glyoxalase I activity and reduced glutathione content. Expression of SIRT3, a deacetylase enzyme related to cellular bioenergetics, was increased in both ovaries and testes. Previous studies have suggested that, in ovaries, diminished antioxidant metabolism can lead to premature ovarian failure. Unfortunately, there is little information regarding the redox profile in the testis. This study is the first to assess the redox network in both ovaries and testes, suggesting that, although intrauterine caloric restriction improves molecular mechanisms, it has a negative effect on the antioxidant network and redox status of reproductive organs of young adult rats.


Subject(s)
Caloric Restriction/adverse effects , Mitochondria/metabolism , Ovary/metabolism , Prenatal Exposure Delayed Effects , Sirtuins/analysis , Testis/metabolism , Animals , Antioxidants/analysis , Antioxidants/metabolism , Female , Male , Ovary/chemistry , Oxidation-Reduction , Pregnancy , Rats , Rats, Wistar , Sirtuin 1/analysis , Sirtuin 3/analysis , Testis/chemistry
2.
Sci Rep ; 10(1): 8620, 2020 05 25.
Article in English | MEDLINE | ID: mdl-32451399

ABSTRACT

Besides technical and tactical aspects, basketball matches involve high aerobic and anaerobic capacities, conferring the final performance of a team. Thus, the evaluation of physical and technical responses is an effective way to predict the performance of athletes. Field and laboratory tests have been used in sports. The first involving high ecological validity and low cost, and the second, greater control and accuracy but not easy application, considering the different preparation phases in a season. This study aimed, through complex networks analysis, to verify whether centrality parameters analysed from significant correlations behave similarly in distinct scenarios (laboratory and on-court), emphasizing aerobic and anaerobic physical parameters and technical performances. The results showed that, in a compelling  analysis involving basketball athletes, the studied centralities (degree, betweenness, eigenvector and pagerank) revealed similar responses in both scenarios, which is widely attractive considering the greater financial economy and lower time when applying tests in the field.

3.
Int J Sports Med ; 38(8): 613-619, 2017 Jul.
Article in English | MEDLINE | ID: mdl-27410767

ABSTRACT

The 3-min all-out test was developed and validated on a cycle ergometer using a modification of a linear mathematical equation (1/time vs. power) obtained from the original critical power model. The purpose of this development was to obtain, in a single test, the aerobic and anaerobic capacity parameters and identify the exercise transition moment from heavy to severe intensity. The aim of this study was to propose an adaptation of the all-out 3-min cycle ergometer to a non-motorized treadmill with tethered running. In addition, we tested the reproducibility of this adapted protocol, highlighting the need for mechanical power evaluation using a specific ergometer. Consequently, 10 physically active individuals visited the laboratory 4 times for testing and data collection. The results suggested that the protocol adaptation for the 3-min all-out test for non-motorized treadmill with tethered running was reproducible and feasible. It was also possible to show that the AO3 application in this ergometer ensures the specificity of the sports that involve the running exercise, from assessment of both aerobic and anaerobic parameters, accomplished in a single day of application.


Subject(s)
Ergometry/methods , Exercise Test/methods , Running/physiology , Adult , Humans , Male , Oxygen Consumption , Reproducibility of Results , Young Adult
4.
Int J Sports Med ; 36(10): 803-8, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26038882

ABSTRACT

The aims of this study were to use a specific all-out 30-sec tethered test to determine the anaerobic parameters in elite kayakers and verify the relationship between these results and sports performance. Twelve elite slalom kayakers were evaluated. The tethered canoe system was created and used for the all-out 30-sec test application. Measurements of peak force, mean force, minimum force, fatigue index and impulse were performed. Performance evaluation was determined by measuring the time of race in a simulated race containing 24 gates on a white-water course. Blood was collected (25-µl) for analysis of lactate concentration at rest and at 2, 4, 6, 8 and 10-min intervals after both the all-out test and the simulated race. The Pearson product moment correlation shows a inverse and significant relationship of peak force, mean force and impulse with time of race. Blood lactate concentrations after the all-out test and the simulated race peak at same time (4 min). Additionally, no interaction was visualized between time and all-out test/simulated race for blood lactate concentrations (P <0.365). These results suggest a relationship between the parameters of the all-out test and performance. Thus, the tethered canoe system is a useful tool for determining parameters that could be used in training control of slalom kayakers.


Subject(s)
Anaerobic Threshold/physiology , Athletic Performance/physiology , Energy Metabolism/physiology , Exercise Test/methods , Adolescent , Heart Rate/physiology , Humans , Lactic Acid/blood , Male , Ships , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...