Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Nutr. hosp ; 38(1): 94-99, ene.-feb. 2021. tab
Article in English | IBECS | ID: ibc-198845

ABSTRACT

INTRODUCTION: body fat reflects important clinical impacts among hemodialysis patients; thus, simple and safe methods are required for a careful evaluation of this body compartment. OBJECTIVES: to evaluate the concordance of estimates of total body fat percentage (%BF), calculated using bioelectrical impedance analysis (BIA) and sum of four skinfolds (SSKD) measures, with those obtained using dual-energy X-ray absorptiometry (DEXA) in patients with chronic kidney disease (CKD) receiving hemodialysis. METHODS: a cross-sectional study was conducted in 317 patients undergoing hemodialysis. The %BF was evaluated using BIA, SSKD measurement, and DEXA, and stratified by sex and tertiles. The Wilcoxon test for paired samples was used to compare the %BF obtained using the different methods, and Lin's concordance correlation coefficient (CCC-L) to evaluate concordance. RESULTS: the average %BF estimated using DEXA was 29.3 ± 9.3 %, with significant differences among the three methods (p < 0.05). SSKD measurement presented a higher CCC-L concordance with DEXA, regardless of sex. After stratification of the sample in tertiles, BIA presented a higher CCC-L concordance with DEXA among the patients with CKD with a %BF above 34.4 % (third tertile). Conversely, SSKD measurement presented better concordance with DEXA for those with a %BF equal to or less than 34.4 %. CONCLUSIONS: in terms of the estimates of the %BF, SSKD measurement displayed a better concordance with DEXA


INTRODUCCIÓN: la grasa corporal refleja importantes impactos clínicos entre los pacientes en hemodiálisis; por lo tanto, se requieren métodos simples y seguros para una evaluación cuidadosa de este compartimiento del cuerpo. OBJETIVOS: evaluar la concordancia de las estimaciones del porcentaje de grasa corporal total (%GC), calculadas mediante el análisis de impedancia bioeléctrica (BIA) y la suma de las medidas de cuatro pliegues cutáneos (CPC), con las obtenidas mediante absorciometría dual energética de rayos X (DEXA) en pacientes con enfermedad renal crónica (ERC) que reciben hemodiálisis. MÉTODOS: se realizó un estudio transversal en 317 pacientes en hemodiálisis. La %GC se evaluó mediante BIA, medición de CPC y DEXA, y se estratificó por sexos y terciles. Se utilizó la prueba de Wilcoxon para muestras pareadas para comparar los %GC obtenidos con los diferentes métodos, y el coeficiente de correlación de concordancia de Lin (CCC-L) para evaluar la concordancia. RESULTADOS: el %GC promedio estimado usando DEXA fue del 29,3 ± 9,3 %, con diferencias significativas entre los tres métodos (p < 0,05). La medición de los CPC presentó una mayor concordancia de CCC-L con DEXA, independientemente del sexo. Tras la estratificación de la muestra en terciles, la BIA presentó una mayor concordancia de CCC-L con DEXA entre los pacientes con ERC con un %GC superior al 34,4 % (tercer tercil). Por el contrario, la medición de los CPC presentó una mejor concordancia con la DEXA para aquellos con un %GC igual o inferior al 34,4 %. CONCLUSIÓN: en términos de las estimaciones del %GC, la medición de los CPC mostró una mejor concordancia con la DEXA


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Skinfold Thickness , Kidney Diseases/complications , Kidney Diseases/diet therapy , Renal Dialysis/methods , Nutrition Assessment , Electric Impedance , Absorptiometry, Photon , Cross-Sectional Studies
2.
Nutr Hosp ; 38(1): 94-99, 2021 Feb 23.
Article in English | MEDLINE | ID: mdl-33319581

ABSTRACT

INTRODUCTION: Introduction: body fat reflects important clinical impacts among hemodialysis patients; thus, simple and safe methods are required for a careful evaluation of this body compartment. Objectives: to evaluate the concordance of estimates of total body fat percentage (%BF), calculated using bioelectrical impedance analysis (BIA) and sum of four skinfolds (SSKD) measures, with those obtained using dual-energy X-ray absorptiometry (DEXA) in patients with chronic kidney disease (CKD) receiving hemodialysis. Methods: a cross-sectional study was conducted in 317 patients undergoing hemodialysis. The %BF was evaluated using BIA, SSKD measurement, and DEXA, and stratified by sex and tertiles. The Wilcoxon test for paired samples was used to compare the %BF obtained using the different methods, and Lin's concordance correlation coefficient (CCC-L) to evaluate concordance. Results: the average %BF estimated using DEXA was 29.3 ± 9.3 %, with significant differences among the three methods (p < 0.05). SSKD measurement presented a higher CCC-L concordance with DEXA, regardless of sex. After stratification of the sample in tertiles, BIA presented a higher CCC-L concordance with DEXA among the patients with CKD with a %BF above 34.4 % (third tertile). Conversely, SSKD measurement presented better concordance with DEXA for those with a %BF equal to or less than 34.4 %. Conclusions: in terms of the estimates of the %BF, SSKD measurement displayed a better concordance with DEXA.


INTRODUCCIÓN: Introducción: la grasa corporal refleja importantes impactos clínicos entre los pacientes en hemodiálisis; por lo tanto, se requieren métodos simples y seguros para una evaluación cuidadosa de este compartimiento del cuerpo. Objetivos: evaluar la concordancia de las estimaciones del porcentaje de grasa corporal total (%GC), calculadas mediante el análisis de impedancia bioeléctrica (BIA) y la suma de las medidas de cuatro pliegues cutáneos (CPC), con las obtenidas mediante absorciometría dual energética de rayos X (DEXA) en pacientes con enfermedad renal crónica (ERC) que reciben hemodiálisis. Métodos: se realizó un estudio transversal en 317 pacientes en hemodiálisis. La %GC se evaluó mediante BIA, medición de CPC y DEXA, y se estratificó por sexos y terciles. Se utilizó la prueba de Wilcoxon para muestras pareadas para comparar los %GC obtenidos con los diferentes métodos, y el coeficiente de correlación de concordancia de Lin (CCC-L) para evaluar la concordancia. Resultados: el %GC promedio estimado usando DEXA fue del 29,3 ± 9,3 %, con diferencias significativas entre los tres métodos (p < 0,05). La medición de los CPC presentó una mayor concordancia de CCC-L con DEXA, independientemente del sexo. Tras la estratificación de la muestra en terciles, la BIA presentó una mayor concordancia de CCC-L con DEXA entre los pacientes con ERC con un %GC superior al 34,4 % (tercer tercil). Por el contrario, la medición de los CPC presentó una mejor concordancia con la DEXA para aquellos con un %GC igual o inferior al 34,4 %. Conclusión: en términos de las estimaciones del %GC, la medición de los CPC mostró una mejor concordancia con la DEXA.


Subject(s)
Absorptiometry, Photon , Adipose Tissue/anatomy & histology , Electric Impedance , Renal Dialysis , Renal Insufficiency, Chronic/therapy , Skinfold Thickness , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Sex Factors , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL
...