Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
EBioMedicine ; 98: 104861, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37924707

ABSTRACT

BACKGROUND: Normothermic regional perfusion (NRP) and hypothermic-oxygenated-perfusion (HOPE), were both shown to improve outcomes after liver transplantation from donors after circulatory death (DCD). Comparative clinical and mechanistical studies are however lacking. METHODS: A rodent model of NRP and HOPE, both in the donor, was developed. Following asystolic donor warm ischemia time (DWIT), the abdominal compartment was perfused either with a donor-blood-based-perfusate at 37 °C (NRP) or with oxygenated Belzer-MPS at 10 °C (donor-HOPE) for 2 h. Livers were then procured and underwent 5 h static cold storage (CS), followed by transplantation. Un-perfused and HOPE-treated DCD-livers (after CS) and healthy livers (DBD) with direct implantation after NRP served as controls. Endpoints included the entire spectrum of ischemia-reperfusion-injury. FINDINGS: Healthy control livers (DBD) showed minimal signs of inflammation during 2 h NRP and achieved 100% posttransplant recipient survival. In contrast, DCD livers with 30 and 60 min DWIT suffered from greater mitochondrial injury and inflammation as measured by increased perfusate Lactate, FMN- and HMGB-1-levels with subsequent Toll-like-receptor activation during NRP. In contrast, donor-HOPE (instead of NRP) led to significantly less mitochondrial-complex-I-injury and inflammation. Results after donor-HOPE were comparable to ex-situ HOPE after CS. Most DCD-liver recipients survived when treated with one HOPE-technique (86%), compared to only 40% after NRP (p = 0.0053). Following a reduction of DWIT (15 min), DCD liver recipients achieved comparable survivals with NRP (80%). INTERPRETATION: High-risk DCD livers benefit more from HOPE-treatment, either immediately in the donor or after cold storage. Comparative prospective clinical studies are required to translate the results. FUNDING: Funding was provided by the Swiss National Science Foundation (grant no: 32003B-140776/1, 3200B-153012/1, 320030-189055/1, and 31IC30-166909) and supported by University Careggi (grant no 32003B-140776/1) and the OTT (grant No.: DRGT641/2019, cod.prog. 19CT03) and the Max Planck Society. Work in the A.G. laboratory was partially supported by the NIH R01NS112381 and R21NS125466 grants.


Subject(s)
Liver Transplantation , Animals , Humans , Liver Transplantation/adverse effects , Liver Transplantation/methods , Rodentia , Prospective Studies , Perfusion/methods , Graft Survival , Organ Preservation/methods , Liver , Tissue Donors , Inflammation
2.
Ann Surg ; 278(5): 669-675, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37497663

ABSTRACT

OBJECTIVE: To develop a protocol for the defatting of steatotic liver grafts during long-term ex situ normothermic machine perfusion. BACKGROUND: Despite the alarming increase in donor organ shortage, the highly prevalent fatty liver grafts are often discarded due to the risk of primary nonfunction. Effective strategies preventing such outcomes are currently lacking. An exciting new avenue is the introduction of ex situ normothermic machine perfusion (NMP), enabling a liver to remain fully functional for up to 2 weeks and providing a unique window of opportunity for defatting before transplantation. METHODS: Over a 5-year period, 23 discarded liver grafts and 28 partial livers from our resection program were tested during ex situ normothermic machine perfusion. The steatosis degree was determined on serial biopsies by expert pathologists, and triglyceride contents were measured simultaneously. RESULTS: Of 51 liver grafts, 20 were steatotic, with up to 85% macrovesicular steatosis, and were perfused for up to 12 days. Ten livers displayed marked (5 of which almost complete) loss of fat, while the other 10 did not respond to long-term perfusion. Successful defatting was related to prolonged perfusion, automated glucose control, circadian nutrition, and L-carnitine/fenofibrate supplementation. Pseudopeliotic steatosis and the associated activation of Kupffer/stellate cells were unexpected processes that might contribute to defatting. Synthetic and metabolic functions remained preserved for most grafts until perfusion ended. CONCLUSION: Ex situ long-term perfusion effectively reduces steatosis while preserving organ viability and may in the future allow transplantation of primarily unusable high-risk grafts, significantly increasing the number of organs available for transplantation.


Subject(s)
Fatty Liver , Liver Transplantation , Humans , Organ Preservation/methods , Liver/pathology , Liver Transplantation/methods , Perfusion/methods
3.
Ann Surg ; 278(5): 748-755, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37465950

ABSTRACT

OBJECTIVE: This study aims at establishing benchmark values for best achievable outcomes following open major anatomic hepatectomy for liver tumors of all dignities. BACKGROUND: Outcomes after open major hepatectomies vary widely lacking reference values for comparisons among centers, indications, types of resections, and minimally invasive procedures. METHODS: A standard benchmark methodology was used covering consecutive patients, who underwent open major anatomic hepatectomy from 44 high-volume liver centers from 5 continents over a 5-year period (2016-2020). Benchmark cases were low-risk non-cirrhotic patients without significant comorbidities treated in high-volume centers (≥30 major liver resections/year). Benchmark values were set at the 75th percentile of median values of all centers. Minimum follow-up period was 1 year in each patient. RESULTS: Of 8044 patients, 2908 (36%) qualified as benchmark (low-risk) cases. Benchmark cutoffs for all indications include R0 resection ≥78%; liver failure (grade B/C) ≤10%; bile leak (grade B/C) ≤18%; complications ≥grade 3 and CCI ® ≤46% and ≤9 at 3 months, respectively. Benchmark values differed significantly between malignant and benign conditions so that reference values must be adjusted accordingly. Extended right hepatectomy (H1, 4-8 or H4-8) disclosed a higher cutoff for liver failure, while extended left (H1-5,8 or H2-5,8) were associated with higher cutoffs for bile leaks, but had superior oncologic outcomes, when compared to formal left hepatectomy (H1-4 or H2-4). The minimal follow-up for a conclusive outcome evaluation following open anatomic major resection must be 3 months. CONCLUSION: These new benchmark cutoffs for open major hepatectomy provide a powerful tool to convincingly evaluate other approaches including parenchymal-sparing procedures, laparoscopic/robotic approaches, and alternative treatments, such as ablation therapy, irradiation, or novel chemotherapy regimens.


Subject(s)
Laparoscopy , Liver Failure , Liver Neoplasms , Humans , Hepatectomy/methods , Benchmarking , Postoperative Complications/etiology , Liver Neoplasms/surgery , Liver Neoplasms/etiology , Liver Failure/etiology , Laparoscopy/methods , Retrospective Studies , Length of Stay
4.
Adv Sci (Weinh) ; 10(23): e2301537, 2023 08.
Article in English | MEDLINE | ID: mdl-37265001

ABSTRACT

Biomarkers are powerful clinical diagnostics and predictors of patient outcome. However, robust measurements often require time and expensive laboratory equipment, which is insufficient to track rapid changes and limits direct use in the operating room. Here, this study presents a portable spectrophotometric device for continuous real-time measurements of fluorescent and non-fluorescent biomarkers at the point of care. This study measures the mitochondrial damage biomarker flavin mononucleotide (FMN) in 26 extended criteria human liver grafts undergoing hypothermic oxygenated perfusion to guide clinical graft assessment. Real-time data identified seven organs unsuitable for transplant that are discarded. The remaining grafts are transplanted and FMN values correlated with post-transplant indicators of liver function and patient recovery. Further, this study shows how this device can be used to monitor dialysis patients by measuring creatinine in real-time. Our approach provides a simple method to monitor biomarkers directly within biological fluids to improve organ assessment, patient care, and biomarker discovery.


Subject(s)
Liver Transplantation , Organ Preservation , Humans , Organ Preservation/methods , Liver Transplantation/methods , Perfusion/methods , Monitoring, Physiologic
5.
J Clin Med ; 12(12)2023 Jun 06.
Article in English | MEDLINE | ID: mdl-37373568

ABSTRACT

The high demand for organs in kidney transplantation and the expansion of the donor pool have led to the widespread implementation of machine perfusion technologies. In this study, we aim to provide an up-to-date systematic review of the developments in this expanding field over the past 10 years, with the aim of answering the question: "which perfusion technique is the most promising technique in kidney transplantation?" A systematic review of the literature related to machine perfusion in kidney transplantation was performed. The primary outcome measure was delayed graft function (DGF), and secondary outcomes included rates of rejection, graft survival, and patient survival rates after 1 year. Based on the available data, a meta-analysis was performed. The results were compared with data from static cold storage, which is still the standard of care in many centers worldwide. A total of 56 studies conducted in humans were included, and 43 studies reported outcomes of hypothermic machine perfusion (HMP), with a DGF rate of 26.4%. A meta-analysis of 16 studies showed significantly lower DGF rates in the HMP group compared to those of static cold storage (SCS). Five studies reported outcomes of hypothermic machine perfusion + O2, with an overall DGF rate of 29.7%. Two studies explored normothermic machine perfusion (NMP). These were pilot studies, designed to assess the feasibility of this perfusion approach in the clinical setting. Six studies reported outcomes of normothermic regional perfusion (NRP). The overall incidence of DGF was 71.5%, as it was primarily used in uncontrolled DCD (Maastricht category I-II). Three studies comparing NRP to in situ cold perfusion showed a significantly lower rate of DGF with NRP. The systematic review and meta-analysis provide evidence that dynamic preservation strategies can improve outcomes following kidney transplantation. More recent approaches such as normothermic machine perfusion and hypothermic machine perfusion + O2 do show promising results but need further results from the clinical setting. This study shows that the implementation of perfusion strategies could play an important role in safely expanding the donor pool.

6.
J Hepatol ; 78(5): 1007-1016, 2023 05.
Article in English | MEDLINE | ID: mdl-36740047

ABSTRACT

BACKGROUND & AIMS: Liver graft utilization rates are a hot topic due to the worldwide organ shortage and the increasing number of transplant candidates on waiting lists. Liver perfusion techniques have been introduced in several countries, and may help to increase the organ supply, as they potentially enable the assessment of livers before use. METHODS: Liver offers were counted from donation after circulatory death (DCD) donors (Maastricht type III) arising during the past decade in eight countries, including Belgium, France, Italy, the Netherlands, Spain, Switzerland, the UK, and the US. Initial type-III DCD liver offers were correlated with accepted, recovered and implanted livers. RESULTS: A total number of 34,269 DCD livers were offered, resulting in 9,780 liver transplants (28.5%). The discard rates were highest in the UK and US, ranging between 70 and 80%. In contrast, much lower DCD liver discard rates, e.g. between 30-40%, were found in Belgium, France, Italy, Spain and Switzerland. In addition, we observed large differences in the use of various machine perfusion techniques, as well as in graft and donor risk factors. For example, the median donor age and functional donor warm ischemia time were highest in Italy, e.g. >40 min, followed by Switzerland, France, and the Netherlands. Importantly, such varying risk profiles of accepted DCD livers between countries did not translate into large differences in 5-year graft survival rates, which ranged between 60-82% in this analysis. CONCLUSIONS: Overall, DCD liver discard rates across the eight countries were high, although this primarily reflects the situation in the Netherlands, the UK and the US. Countries where in situ and ex situ machine perfusion strategies were used routinely had better DCD utilization rates without compromised outcomes. IMPACT AND IMPLICATIONS: A significant number of Maastricht type III DCD livers are discarded across Europe and North America today. The overall utilization rate among eight Western countries is 28.5% but varies significantly between 18.9% and 74.2%. For example, the median DCD-III liver utilization in five countries, e.g. Belgium, France, Italy, Switzerland, and Spain is 65%, in contrast to 24% in the Netherlands, UK and US. Despite this, and despite different rules and strategies for organ acceptance and preservation, 1- and 5-year graft survival rates remain fairly similar among all participating countries. A highly varying experience with modern machine perfusion technology was observed. In situ and ex situ liver perfusion concepts, and application of assessment tools for type-III DCD livers before transplantation, may be a key explanation for the observed differences in DCD-III utilization.


Subject(s)
Cardiovascular System , Liver Transplantation , Tissue and Organ Procurement , Humans , Liver , Tissue Donors , Liver Transplantation/methods , Graft Survival , Organ Preservation/methods , Perfusion/methods
7.
J Hepatol ; 78(4): 783-793, 2023 04.
Article in English | MEDLINE | ID: mdl-36681160

ABSTRACT

BACKGROUND & AIMS: Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. METHODS: In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. RESULTS: Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). CONCLUSIONS: HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. IMPACT AND IMPLICATIONS: This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.


Subject(s)
Liver Transplantation , Organ Preservation , Humans , Organ Preservation/methods , Perfusion/methods , Liver , Liver Transplantation/adverse effects , Liver Transplantation/methods , Brain Death , Postoperative Complications , Graft Survival
8.
Artif Organs ; 47(2): 317-329, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36106378

ABSTRACT

BACKGROUND: Ex situliver machine perfusion at subnormothermic/normothermic temperature isincreasingly applied in the field of transplantation to store and evaluateorgans on the machine prior transplantation. Currently, various perfusionconcepts are in clinical and preclinical applications. Over the last 6 years ina multidisciplinary team, a novel blood based perfusion technology wasdeveloped to keep a liver alive and metabolically active outside of the bodyfor at least one week. METHODS: Within thismanuscript, we present and compare three scenarios (Group 1, 2 and 3) we werefacing during our research and development (R&D) process, mainly linked tothe measurement of free hemoglobin and lactate in the blood based perfusate. Apartfrom their proven value in liver viability assessment (ex situ), these twoparameters are also helpful in R&D of a long-term liver perfusion machine and moreover supportive in the biomedical engineering process. RESULTS: Group 1 ("good" liver on the perfusion machine) represents the best liver clearance capacity for lactate and free hemoglobin wehave observed. In contrast to Group 2 ("poor" liver on the perfusion machine), that has shown the worst clearance capacity for free hemoglobin. Astonishingly,also for Group 2, lactate is cleared till the first day of perfusion andafterwards, rising lactate values are detected due to the poor quality of theliver. These two perfusate parametersclearly highlight the impact of the organ quality/viability on the perfusion process. Whereas Group 3 is a perfusion utilizing a blood loop only (without a liver). CONCLUSION: Knowing the feasible ranges (upper- and lower bound) and the courseover time of free hemoglobin and lactate is helpful to evaluate the quality ofthe organ perfusion itself and the maturity of the developed perfusion device. Freehemoglobin in the perfusate is linked to the rate of hemolysis that indicates how optimizing (gentle blood handling, minimizing hemolysis) the perfusion machine actually is. Generally, a reduced lactate clearancecapacity can be an indication for technical problems linked to the blood supplyof the liver and therefore helps to monitor the perfusion experiments.Moreover, the possibility is given to compare, evaluate and optimize developed liverperfusion systems based on the given ranges for these two parameters. Otherresearch groups can compare/quantify their perfusate (blood) parameters withthe ones in this manuscript. The presented data, findings and recommendations willfinally support other researchers in developing their own perfusion machine ormodifying commercially availableperfusion devices according to their needs.


Subject(s)
Hemolysis , Liver Transplantation , Humans , Organ Preservation , Liver , Perfusion , Lactates , Hemoglobins
9.
Front Transplant ; 2: 1132673, 2023.
Article in English | MEDLINE | ID: mdl-38993877

ABSTRACT

Introduction: The gap between available donor grafts and patients on the waiting lists is constantly growing. This leads to an increased utilization of high-risk and therefore more vulnerable kidney grafts. The use of high-risk organs requires further optimization of machine preservation and assessment strategies before transplantation. Hypothermic machine perfusion (HMP) is the standard of care for kidneys originating from donation after circulatory death (DCD), whereas the evidence of HMP with additional oxygen (HOPE) is still very limited. Furthermore, an objective quality assessment of HMP-perfused kidneys is lacking. Recently, the release of mitochondria derived fragments, i.e., flavin mononucleotide (FMN) of complex I during machine liver perfusion was shown to be predictive for liver graft function before implantation. Therefore, the aim of this study was to evaluate, if FMN is useful also for assessment of kidney injury before use. Methods: A porcine perfusion model was used to investigate the feasibility of assessment of kidney grafts during hypothermic oxygenated perfusion (HOPE) with either 0, 30 or 60 minutes of warm ischemia. The model with warm ischemia times (WIT) of 30 min and 60 min, was used to mimic a clinically relevant scenario. A group with no warm ischemia time (0' WIT) served as control group. The groups underwent minimal static cold storage (SCS) of 2 h followed by 2 h of end-ischemic HOPE with repeated real-time FMN measurements. In a further step, these values were related to the release of damage-associated molecular patterns (DAMPs) and to the functionality of the respiratory chain, represented by the capacity of ATP production. Results: We demonstrate, first, feasibility of perfusate FMN measurements in perfused kidneys, and secondly its correlation with donor warm ischemia time. Accordingly, FMN measurement showed significantly higher release in the 60-minute WIT group (n = 4) compared to the 30-minute WIT (n = 4) and the control group (n = 4). FMN release correlated also with DAMP signaling, such as the release of 8-OHdG and HMGB1. Finally, ATP replenishment proved to be best in control kidneys, followed by kidneys with 30 min and then by kidneys with 60 min of WIT. Discussion: This study demonstrates the feasibility of FMN measurement in kidneys during HOPE. In addition, we show a correlation between FMN quantification and pre-existing kidney graft injury. Based on this, real-time FMN measurement during HOPE may be an objective assessment tool to accept high-risk kidneys for transplantation while minimizing post-transplant dysfunction, moving away from former "gut feeling" towards objective criteria in accepting marginal kidney grafts for transplantation. Graft evaluation based on these results may close the gap between available grafts and patients on the waiting lists by increasing utilization rates without significant impact for the recipients.

10.
Liver Transpl ; 28(12): 1888-1898, 2022 12.
Article in English | MEDLINE | ID: mdl-35735232

ABSTRACT

This study investigated the effect of low-dose aspirin in primary adult liver transplantation (LT) on acute cellular rejection (ACR) as well as arterial patency rates. The use of low-dose aspirin after LT is practiced by many transplant centers to minimize the risk of hepatic artery thrombosis (HAT), although solid recommendations do not exist. However, aspirin also possesses potent anti-inflammatory properties and might mitigate inflammatory processes after LT, such as rejection. Therefore, we hypothesized that the use of aspirin after LT has a protective effect against ACR. This is an international, multicenter cohort study of primary adult deceased donor LT. The study included 17 high-volume LT centers and covered the 3-year period from 2013 to 2015 to allow a minimum 5-year follow-up. In this cohort of 2365 patients, prophylactic antiplatelet therapy with low-dose aspirin was administered in 1436 recipients (61%). The 1-year rejection-free survival rate was 89% in the aspirin group versus 82% in the no-aspirin group (hazard ratio [HR], 0.77; 95% confidence interval [CI], 0.63-0.94; p = 0.01). The 1-year primary arterial patency rates were 99% in the aspirin group and 96% in the no-aspirin group with an HR of 0.23 (95% CI, 0.13-0.40; p < 0.001). Low-dose aspirin was associated with a lower risk of ACR and HAT after LT, especially in the first vulnerable year after transplantation. Therefore, low-dose aspirin use after primary LT should be evaluated to protect the liver graft from ACR and to maintain arterial patency.


Subject(s)
Liver Transplantation , Thrombosis , Adult , Humans , Liver Transplantation/adverse effects , Cohort Studies , Graft Rejection/prevention & control , Thrombosis/etiology , Thrombosis/prevention & control , Allografts , Graft Survival , Retrospective Studies , Risk Factors
11.
Nat Biotechnol ; 40(11): 1610-1616, 2022 11.
Article in English | MEDLINE | ID: mdl-35641829

ABSTRACT

Current organ preservation methods provide a narrow window (usually <12 hours) to assess, transport and implant donor grafts for human transplantation. Here we report the transplantation of a human liver discarded by all centers, which could be preserved for several days using ex situ normothermic machine perfusion. The transplanted liver exhibited normal function, with minimal reperfusion injury and the need for only a minimal immunosuppressive regimen. The patient rapidly recovered a normal quality of life without any signs of liver damage, such as rejection or injury to the bile ducts, according to a 1-year follow up. This inaugural clinical success opens new horizons in clinical research and promises an extended time window of up to 10 days for assessment of viability of donor organs as well as converting an urgent and highly demanding surgery into an elective procedure.


Subject(s)
Liver Transplantation , Quality of Life , Humans , Liver Transplantation/methods , Organ Preservation/methods , Perfusion/methods , Liver/surgery
12.
Hepatology ; 76(5): 1531-1549, 2022 11.
Article in English | MEDLINE | ID: mdl-35488496

ABSTRACT

Although liver transplantation is a true success story, many patients still die awaiting an organ. The increasing need for liver grafts therefore remains an unsolved challenge to the transplant community. To address this, transplant donor criteria have been expanded and, for example, more liver grafts with significant steatosis or from donors with circulatory death are being used. These marginal grafts, however, carry an increased risk of graft-associated complications, such as primary nonfunction, delayed graft function, or late biliary injuries. Therefore, reliable assessment of graft viability before use is essential for further success. To achieve this, machine liver perfusion, a procedure developed more than 50 years ago but almost forgotten at the end of the last century, is again of great interest. We describe in this review the clinical most applied machine perfusion techniques, their mechanistic background, and a novel concept of combining immediate organ assessment during hypothermic oxygenated perfusion, followed by an extended phase of normothermic machine perfusion, with simultaneous ex situ treatment of the perfused liver. Such a new approach may allow the pool of usable livers to dramatically increase and improve outcomes for recipients.


Subject(s)
Liver Transplantation , Perfusion , Postoperative Complications , Humans , Liver Transplantation/adverse effects , Liver Transplantation/methods , Perfusion/instrumentation , Perfusion/methods , Postoperative Complications/prevention & control , Tissue Donors
13.
Ann Surg ; 274(5): 836-842, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34334640

ABSTRACT

OBJECTIVE: The aim of this study was to maintain long-term full function and viability of partial livers perfused ex situ for sufficient duration to enable ex situ treatment, repair, and regeneration. BACKGROUND: Organ shortage remains the single most important factor limiting the success of transplantation. Autotransplantation in patients with nonresectable liver tumors is rarely feasible due to insufficient tumor-free remnant tissue. This limitation could be solved by the availability of long-term preservation of partial livers that enables functional regeneration and subsequent transplantation. METHODS: Partial swine livers were perfused with autologous blood after being procured from healthy pigs following 70% in-vivo resection, leaving only the right lateral lobe. Partial human livers were recovered from patients undergoing anatomic right or left hepatectomies and perfused with a blood based perfusate together with various medical additives. Assessment of physiologic function during perfusion was based on markers of hepatocyte, cholangiocyte, vascular and immune compartments, as well as histology. RESULTS: Following the development phase with partial swine livers, 21 partial human livers (14 right and 7 left hemi-livers) were perfused, eventually reaching the targeted perfusion duration of 1 week with the final protocol. These partial livers disclosed a stable perfusion with normal hepatic function including bile production (5-10 mL/h), lactate clearance, and maintenance of energy exhibited by normal of adenosine triphosphate (ATP) and glycogen levels, and preserved liver architecture for up to 1 week. CONCLUSION: This pioneering research presents the inaugural evidence for long-term machine perfusion of partial livers and provides a pathway for innovative and relevant clinical applications to increase the availability of organs and provide novel approaches in hepatic oncology.


Subject(s)
Liver Diseases/surgery , Liver Regeneration/physiology , Liver Transplantation/methods , Liver/physiopathology , Organ Preservation/methods , Perfusion/methods , Animals , Disease Models, Animal , Follow-Up Studies , Humans , Liver/surgery , Liver Diseases/physiopathology , Retrospective Studies , Swine , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...