J Biomed Mater Res A ; 102(5): 1486-99, 2014 May.
Article in English | MEDLINE | ID: mdl-23666919

ABSTRACT

The performance of neural electrodes implanted in the brain is often limited by host response in the surrounding brain tissue, including astrocytic scar formation, neuronal cell death, and inflammation around the implant. We applied conformal microgel coatings to silicon neural electrodes and examined host responses to microgel-coated and uncoated electrodes following implantation in the rat brain. In vitro analyses demonstrated significantly reduced astrocyte and microglia adhesion to microgel-coated electrodes compared to uncoated controls. Microgel-coated and uncoated electrodes were implanted in the rat brain cortex and the extent of activated microglia and astrocytes as well as neuron density around the implant were evaluated at 1, 4, and 24 weeks postimplantation. Microgel coatings reduced astrocytic recruitment around the implant at later time points. However, microglial response indicated persistence of inflammation in the area around the electrode. Neuronal density around the implanted electrodes was also lower for both implant groups compared to the uninjured control. These results demonstrate that microgel coatings do not significantly improve host responses to implanted neural electrodes and underscore the need for further improvements in implantable materials.


Subject(s)
Brain/physiology , Coated Materials, Biocompatible/pharmacology , Electrodes, Implanted , Gels/pharmacology , Neurons/physiology , Animals , Antigens, CD/metabolism , Antigens, Differentiation, Myelomonocytic/metabolism , Brain/drug effects , CD11b Antigen/metabolism , Cell Adhesion/drug effects , Glial Fibrillary Acidic Protein/metabolism , Immunohistochemistry , Neuroglia/cytology , Neurons/drug effects , Rats
3.
Anal Chem ; 82(2): 523-30, 2010 Jan 15.
Article in English | MEDLINE | ID: mdl-20000662

ABSTRACT

We describe the synthesis and characterization of degradable nanogels that display bulk erosion under physiologic conditions (pH = 7.4, 37 degrees C). Erodible poly(N-isopropylmethacrylamide) nanogels were synthesized by copolymerization with N,O-(dimethacryloyl) hydroxylamine, a cross-linker previously used in the preparation of nontoxic and biodegradable bulk hydrogels. To monitor particle degradation, we employed multiangle light scattering and differential refractometry detection following asymmetrical flow field-flow fractionation. This approach allowed the detection of changes in nanogel molar mass and topology as a function of both temperature and pH. Particle erosion was evident from both an increase in nanogel swelling and a decrease in scattering intensity as a function of time. Following these analyses, the samples were recovered for subsequent characterization by direct particle tracking, which yields hydrodynamic size measurements and enables number density determination. Additionally, we confirmed the conservation of nanogel stimuli-responsivity through turbidity measurements. Thus, we have demonstrated the synthesis of degradable nanogels that erode under conditions and on time scales that are relevant for many drug delivery applications. The combined separation and light scattering detection method is demonstrated to be a versatile means to monitor erosion and should also find applicability in the characterization of other degradable particle constructs.


Subject(s)
Nanoparticles/chemistry , Refractometry/methods , Scattering, Radiation , Acrylamides/chemistry , Hydrogen-Ion Concentration , Polymers/chemistry , Temperature
4.
ACS Appl Mater Interfaces ; 1(12): 2747-54, 2009 Dec.
Article in English | MEDLINE | ID: mdl-20356152

ABSTRACT

Thin films assembled from microgel building blocks have been constructed using a simple, high-throughput, and reproducible centrifugation (or "active") deposition technique. When compared to a common passive adsorption method (e.g., dip coating), microgels that are actively deposited onto a surface have smaller footprints and are more closely packed. Under both active and passive deposition conditions, the microgel footprint areas decrease during deposition. However, under active deposition, the microgel footprint appears to decrease continually and to a greater degree over the course of the deposition, forming a tightly packed, homogeneous film. Taking advantage of the rapid and uniform assembly of these films, we demonstrate the use of active deposition toward the fabrication of polyelectrolyte multilayers containing anionic microgels and a cationic linear polymer. Microgel multilayers successfully demonstrated effective blocking of the underlying substrate toward macrophage adhesion, which is a highly sought-after property for modulating the inflammatory response to an implanted biomaterial.


Subject(s)
Biofouling , Centrifugation/methods , Gels/chemistry , Microscopy, Atomic Force , Microscopy, Fluorescence , Time Factors
SELECTION OF CITATIONS