Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 9(Pt 4): 223-8, 2002 Jul 01.
Article in English | MEDLINE | ID: mdl-12091730

ABSTRACT

A surface profile retrieval technique from multiple X-ray total reflection images taken at various distances with full coherent illumination is demonstrated. An experiment was performed using the 1 km-long BL29XU beamline at the SPring-8 facility, Japan. Obtained results are compared with results from the optical metrology technique (Fizeau's interferometer). Good agreement between X-ray and optical methods proves the validity of the current approach. Meanwhile, the sensitivity of the X-ray technique is several times higher than that of the standard one. This technique is well suited to the needs of characterizing grazing optics for new-generation X-ray sources.

2.
IEEE Trans Biomed Eng ; 48(9): 1053-6, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11534841

ABSTRACT

Microwave tomographic approach is proposed to detect and image breast cancers. Taking into account the big difference in dielectrical properties between normal and malignant tissues, we have proposed using the microwave tomographic method to image a human breast. Because of the anatomical features of the objects, this case has to be referred to the tomography with a limited angle of observation. As a result of computer experiments we have established that multiview cylindrical configurations are able to provide microwave tomograms of the breast with a small size tumor inside. Using the gradient method, we have developed a computer code to create images of the three-dimensional objects in dielectrical properties on microwave frequencies.


Subject(s)
Breast Neoplasms/diagnosis , Image Processing, Computer-Assisted , Microwaves , Algorithms , Female , Humans , Mathematical Computing , Models, Anatomic
3.
Ann Biomed Eng ; 29(5): 427-35, 2001 May.
Article in English | MEDLINE | ID: mdl-11400723

ABSTRACT

A model of dielectrical properties of cellular structures of a tissue has been proposed. Cellular structures were presented as a composition of membrane covered spheres and cylinders that do not interact with each other. No restrictions were applied to the thickness of cellular membranes. The model was further generalized into a case of electrically interacting cells. The difference in dielectrical properties calculated with the model of electrically noninteracting versus interacting cells is inversely dependent on frequency. At biological values of cellular volume fraction near 0.7 (packed configuration) the difference is about 10%-15% in resistance and in epsilon' for frequencies near 0.1 MHz. Experimental data for myocardial tissue and theoretical data, for both interacting and noninteracting models, reasonably agree at frequencies of 1-100 MHz.


Subject(s)
Heart/physiology , Microwaves , Models, Cardiovascular , Radio Waves , Animals , Biomedical Engineering , Cell Membrane/physiology , Dogs , Electric Conductivity , Electrophysiology , Female , Male
4.
Ann Biomed Eng ; 28(1): 55-60, 2000 Jan.
Article in English | MEDLINE | ID: mdl-10645788

ABSTRACT

The proposed dielectrical relaxation model of the myocardium in the microwave spectrum has been verified both on test solutions and on normal canine myocardium. Furthermore, the model was utilized to reconstruct the changes in tissue properties (including myocardial bulk resistance and water content) following myocardial acute ischemia and chronic infarction. It was shown that the reconstructed myocardial resistance and water content correlate dynamically with the process of the development of acute myocardial ischemic injury. In chronic cases the reconstructed resistance and water content of infarcted myocardium are significantly different from that of normal myocardium: the resistance is lower and water content is higher than in normal myocardium.


Subject(s)
Microwaves , Myocardial Infarction/pathology , Myocardial Infarction/physiopathology , Myocardial Ischemia/pathology , Myocardial Ischemia/physiopathology , Tomography/methods , Acute Disease , Animals , Biomedical Engineering , Biophysical Phenomena , Biophysics , Body Water/metabolism , Chronic Disease , Dogs , Electrophysiology , Female , Male , Models, Cardiovascular
5.
IEEE Trans Biomed Eng ; 46(8): 937-46, 1999 Aug.
Article in English | MEDLINE | ID: mdl-10431458

ABSTRACT

A method of image reconstruction in three-dimensional (3-D) microwave tomography in a weak dielectric contrast case has been developed. By utilizing only one component of the vector electromagnetic field this method allows successful reconstruction of images of 3-D mathematical phantoms. A prototype of the 3-D microwave tomographic system capable of imaging 3-D objects has been constructed. The system operates at a frequency of 2.36 GHz and utilizes a code-division technique. With dimensions of the cylindrical working chamber z = 40 cm and d = 60 cm, the system allows measurement of an attenuation up to 120 dB having signal-to-noise ratio about 30 dB. The direct problem solutions for different mathematical approaches were compared with an experimentally measured field distribution inside the working chamber. The tomographic system and the reconstruction method were tested in simple experimental imaging.


Subject(s)
Image Processing, Computer-Assisted/methods , Microwaves , Models, Cardiovascular , Tomography/methods , Electromagnetic Fields , Equipment Design , Humans , Nonlinear Dynamics , Phantoms, Imaging , Tomography/instrumentation , Vectorcardiography/methods
6.
Article in English | MEDLINE | ID: mdl-11970673

ABSTRACT

We present a quantitative study of specular and diffuse (non-specular) x-ray and neutron reflectivity from highly aligned phospholipid membranes deposited on solid substrates. The height-height correlation function could be obtained from the diffuse scattering without further model assumptions. The results differ significantly from the linear theory of smectic elasticity. We argue that the diffuse scattering is dominated by static liquid-crystalline defects, rather than thermal fluctuations.


Subject(s)
1,2-Dipalmitoylphosphatidylcholine/chemistry , Membrane Lipids/chemistry , Diffusion , Lipid Bilayers/chemistry , Membrane Fluidity , Neutrons , Scattering, Radiation , X-Ray Diffraction
7.
Appl Opt ; 37(4): 653-62, 1998 Feb 01.
Article in English | MEDLINE | ID: mdl-18268637

ABSTRACT

Compound lenses made from low-Z materials (e.g., Be, B, C, and Al) set up as a linear array of refractive lenses are proposed for submicrometer focusing of high-energy x rays (>5 keV) in one or two dimensions. A theory of focusing based on Maxwell's equation and the Fresnel-Kirchhoff approach is presented. Compound refractive lenses were manufactured by drilling into an Al block a linear array of 200 closely spaced holes 0.5 mm in diameter for linear focusing and two crossed arrays of 100 holes each for point focusing. Focal spots of 3.7 mum and 8 mum x 18 mum were obtained at 30 keV for linear and two-dimensional lenses, respectively. Different technologies of manufacturing and possible applications of the proposed lenses are discussed.

8.
IEEE Trans Biomed Eng ; 43(9): 869-77, 1996 Sep.
Article in English | MEDLINE | ID: mdl-9214802

ABSTRACT

Microwave tomographic imaging is one of the new technologies which has the potential for important applications in medicine. Microwave tomographically reconstructed images may potentially provide information about the physiological state of tissue as well as the anatomical structure of an organ. A two-dimensional (2-D) prototype of a quasi real-time microwave tomographic system was constructed. It was utilized to reconstruct images of physiologically active biological tissues such as an explanted canine perfused heart. The tomographic system consisted of 64 special antennae, divided into 32 emitters and 32 receivers which were electronically scanned. The cylindrical microwave chamber had an internal diameter of 360 mm and was filled with various solutions, including deionized water. The system operated on a frequency of 2.45 GHz. The polarization of the incident electromagnetic field was linear in the vertical direction. Total acquisition time was less than 500 ms. Both accurate and approximation methods of image reconstruction were used. Images of 2-D phantoms, canine hearts, and beating canine hearts have been achieved. In the worst-case situation when the 2-D diffraction model was used for an attempt to "slice" three-dimensional (3-D) object reconstruction, we still achieved spatial resolution of 1 to 2 cm and contrast resolution of 5%.


Subject(s)
Microwaves , Tomography/methods , Animals , Dogs , Heart/anatomy & histology , Image Processing, Computer-Assisted/methods , Models, Cardiovascular , Phantoms, Imaging , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...