Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Pulmonology ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38760225

ABSTRACT

INTRODUCTION AND OBJECTIVES: Quantifying breathing effort in non-intubated patients is important but difficult. We aimed to develop two models to estimate it in patients treated with high-flow oxygen therapy. PATIENTS AND METHODS: We analyzed the data of 260 patients from previous studies who received high-flow oxygen therapy. Their breathing effort was measured as the maximal deflection of esophageal pressure (ΔPes). We developed a multivariable linear regression model to estimate ΔPes (in cmH2O) and a multivariable logistic regression model to predict the risk of ΔPes being >10 cmH2O. Candidate predictors included age, sex, diagnosis of the coronavirus disease 2019 (COVID-19), respiratory rate, heart rate, mean arterial pressure, the results of arterial blood gas analysis, including base excess concentration (BEa) and the ratio of arterial tension to the inspiratory fraction of oxygen (PaO2:FiO2), and the product term between COVID-19 and PaO2:FiO2. RESULTS: We found that ΔPes can be estimated from the presence or absence of COVID-19, BEa, respiratory rate, PaO2:FiO2, and the product term between COVID-19 and PaO2:FiO2. The adjusted R2 was 0.39. The risk of ΔPes being >10 cmH2O can be predicted from BEa, respiratory rate, and PaO2:FiO2. The area under the receiver operating characteristic curve was 0.79 (0.73-0.85). We called these two models BREF, where BREF stands for BReathing EFfort and the three common predictors: BEa (B), respiratory rate (RE), and PaO2:FiO2 (F). CONCLUSIONS: We developed two models to estimate the breathing effort of patients on high-flow oxygen therapy. Our initial findings are promising and suggest that these models merit further evaluation.

2.
Eur Rev Med Pharmacol Sci ; 27(22): 11192-11199, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38039051

ABSTRACT

OBJECTIVE: Investigating the experiences perceived by COVID-19 inpatients is a fundamental research area that is starting to be explored. For this reason, our objective was to provide the first Italian survey on COVID-19 inpatients' satisfaction, obtained through a self-completed questionnaire previously used in a reference study in a UK cohort of COVID-19 patients. SUBJECTS AND METHODS: Hospitalized COVID-19 patients (>20 days) admitted to Ferrara University Hospital who underwent rehabilitation during their hospital stay were invited to complete an anonymous questionnaire. The survey's questions explored the patients' satisfaction with the health services received, and their completion took place approximately one year after hospitalization. Information on sex, number of wards, ICU stays, and hospital discharge dates was collected. RESULTS: Sixty-two completed questionnaires were analyzed. The average overall satisfaction score obtained from the answers indicated by the participants in the tenth question was 4.7 out of 5.0. Very positive responses were observed for information about discharge plans, privacy, management of pain, sleep quality, and feeling of safety. The possibility of being consulted about medications and side effects received a very low satisfaction score. Considering overall satisfaction, no significant differences were noted for sex or ICU stay. The obtained results were almost superimposable to those reported in the cohort of COVID-19 patients of the reference study. CONCLUSIONS: This survey suggested that COVID-19 patients' healthcare satisfaction was high. Nevertheless, some areas must be improved, such as the communication and involvement of the patients in the decision-making of care and the discussion about medications or possible side effects.


Subject(s)
COVID-19 , Humans , COVID-19/therapy , Hospitalization , Surveys and Questionnaires , Critical Care , Patient Satisfaction , Hospitals, University
3.
Eur Rev Med Pharmacol Sci ; 26(5): 1765-1769, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35302229

ABSTRACT

OBJECTIVE: Few data are available on the ICU management and on the possible respiratory complications of invasively ventilated pregnant patients affected by COVID-19 pneumonia, especially in the early phase of pregnancy. Tension pneumothorax has been previously described as a rare cause of respiratory failure after delivery, but its occurrence in the postpartum of COVID-19 patient has not been reported yet. We hereby describe the ICU management of a 23rd gestational week pregnant woman who underwent invasive mechanical ventilation, prone positioning, and cesarean delivery during her ICU stay for COVID-19 related pneumonia. Moreover, we focused on the occurrence and management of recurrent tension pneumothorax after the cesarean delivery. CASE REPORT: A 23rd gestational week pregnant woman was admitted to the ICU for a COVID-19 bilateral pneumonia and underwent invasive mechanical ventilation and prone positioning. Cesarean delivery was planned during the ICU stay, while the patient was receiving invasive mechanical ventilation. After delivery, the patient experienced a recurrent pneumothorax that required the positioning of multiple chest drains. CONCLUSIONS: In pregnant critically ill COVID-19 patients, mechanical ventilation management is particularly challenging, especially in the postpartum period. Prone positioning is feasible and can improve oxygenation and respiratory system compliance, while tension pneumothorax must be suspected if the respiratory function suddenly deteriorates after delivery.


Subject(s)
COVID-19/complications , Cesarean Section , Critical Illness , Pneumothorax/etiology , Postoperative Complications/therapy , Respiratory Distress Syndrome/etiology , Respiratory Distress Syndrome/therapy , Adult , COVID-19/diagnostic imaging , Female , Humans , Infant, Newborn , Postoperative Complications/diagnostic imaging , Pregnancy , Prone Position , Recurrence , Respiration, Artificial , Respiratory Distress Syndrome/diagnostic imaging , Treatment Outcome
4.
Eur Rev Med Pharmacol Sci ; 24(6): 2795-2801, 2020 03.
Article in English | MEDLINE | ID: mdl-32271396

ABSTRACT

OBJECTIVE: Every year 0.5-2% of women undergo non-obstetric surgery in pregnancy. Hypoxic events with short-term and long-term consequences are one of the most frequent complications in surgery. There is only limited data available regarding the impact of these events. This review aims to analyze the current literature on hypoxic events occurring in non-obstetric abdominal surgery in pregnant women, focused on maternal and fetal outcomes. MATERIALS AND METHODS: We performed a non-systematic review of the literature, through a PubMed search using the key words "hypoxemia", "non-obstetric surgery", "surgical procedures", "pregnancy", "pregnant women" and "outcome". RESULTS: There is little data available regarding maternal and fetal outcomes after hypoxic episodes during non-obstetric surgery in pregnancy. In these cases, conservative intrauterine resuscitation maneuvers or immediate delivery should be taken into account. Perimortem cesarean section can be lifesaving for both mother and fetus when maternal collapse is non responsive to resuscitation procedures. Inaccurate information regarding maternal and fetal outcomes is due to the lack of robust data and the heterogeneity of the causes underlying maternal respiratory complications during surgery. CONCLUSIONS: Non-obstetric surgery during pregnancy must be performed when indicated. An expert multidisciplinary team, composed of obstetricians, surgeons, and anesthesiologists need to be included, giving appropriate attention to the physiological changes of respiratory, cardiovascular, and gastrointestinal system that occur during pregnancy. The shortest operative time and peri-operative assistance should be ensured. Complications, such as hypoxic events in pregnant patients need adequate assistance. Multidisciplinary cooperation, continuous training and simulation for anesthesiology and resuscitative procedures can guarantee this.


Subject(s)
Hypoxia/surgery , Pregnancy Complications/surgery , Pregnant Women , Female , Humans , Pregnancy
5.
Acta Neurol Belg ; 120(2): 277-288, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32112349

ABSTRACT

Hypoxic-ischemic encephalopathy, also referred as HIE, is a type of brain injury or damage that is caused by a lack of oxygen to the brain during neonatal period. The incidence is approximately 1.5 cases per 1000 live births in developed countries. In low and middle-income countries, the incidence is much higher (10‒20 per 1000 live births). The treatment for neonatal HIE is hypothermia that is only partially effective (not more than 50% of the neonates treated achieve an improved outcome). HIE pathophysiology involves oxidative stress, mitochondrial energy production failure, glutaminergic excitotoxicity, and apoptosis. So, in the last years, many studies have focused on peptides that act somewhere in the pathway activated by severe anoxic injury leading to HIE. This review describes the pathophysiology of perinatal HIE and the mechanisms that could be the target of innovative HIE treatments.


Subject(s)
Asphyxia Neonatorum/complications , Hypoxia-Ischemia, Brain/etiology , Hypoxia-Ischemia, Brain/physiopathology , Female , Humans , Infant, Newborn , Male
6.
Anesthesiology ; 131(2): 266-278, 2019 08.
Article in English | MEDLINE | ID: mdl-31166236

ABSTRACT

BACKGROUND: Postoperative diaphragmatic dysfunction after thoracic surgery is underestimated due to the lack of reproducible bedside diagnostic methods. We used point of care ultrasound to assess diaphragmatic function bedside in patients undergoing video-assisted thoracoscopic or thoracotomic lung resection. Our main hypothesis was that the thoracoscopic approach may be associated with lower incidence of postoperative diaphragm dysfunction as compared to thoracotomy. Furthermore, we assessed the association between postoperative diaphragmatic dysfunction and postoperative pulmonary complications. METHODS: This was a prospective observational cohort study. Two cohorts of patients were evaluated: those undergoing video-assisted thoracoscopic surgery versus those undergoing thoracotomy. Diaphragmatic dysfunction was defined as a diaphragmatic excursion less than 10 mm. The ultrasound evaluations were carried out before (preoperative) and after (i.e., 2 h and 24 h postoperatively) surgery. The occurrence of postoperative pulmonary complications was assessed up to 7 days after surgery. RESULTS: Among the 75 patients enrolled, the incidence of postoperative diaphragmatic dysfunction at 24 h was higher in the thoracotomy group as compared to video-assisted thoracoscopic surgery group (29 of 35, 83% vs. 22 of 40, 55%, respectively; odds ratio = 3.95 [95% CI, 1.5 to 10.3]; P = 0.005). Patients with diaphragmatic dysfunction on the first day after surgery had higher percentage of postoperative pulmonary complications (odds ratio = 5.5 [95% CI, 1.9 to 16.3]; P = 0.001). Radiologically assessed atelectasis was 46% (16 of 35) in the thoracotomy group versus 13% (5 of 40) in the video-assisted thoracoscopic surgery group (P = 0.040). Univariate logistic regression analysis indicated postoperative diaphragmatic dysfunction as a risk factor for postoperative pulmonary complications (odds ratio = 5.5 [95% CI, 1.9 to 16.3]; P = 0.002). CONCLUSIONS: Point of care ultrasound can be used to evaluate postoperative diaphragmatic function. On the first postoperative day, diaphragmatic dysfunction was less common after video-assisted than after the thoracotomic surgery and is associated with postoperative pulmonary complications.


Subject(s)
Diaphragm/physiopathology , Point-of-Care Systems , Postoperative Complications/diagnostic imaging , Thoracic Surgery, Video-Assisted/adverse effects , Thoracotomy/adverse effects , Ultrasonography/methods , Aged , Cohort Studies , Diaphragm/diagnostic imaging , Female , Humans , Male , Postoperative Complications/etiology , Postoperative Complications/physiopathology , Prospective Studies , Reproducibility of Results , Risk Factors
7.
J Clin Monit Comput ; 31(4): 773-781, 2017 Aug.
Article in English | MEDLINE | ID: mdl-27344663

ABSTRACT

Incomplete expiration of tidal volume can lead to dynamic hyperinflation and auto-PEEP. Methods are available for assessing these, but are not appropriate for patients with respiratory muscle activity, as occurs in pressure support. Information may exist in expiratory flow and carbon dioxide measurements, which, when taken together, may help characterize dynamic hyperinflation. This paper postulates such patterns and investigates whether these can be seen systematically in data. Two variables are proposed summarizing the number of incomplete expirations quantified as a lack of return to zero flow in expiration (IncExp), and the end tidal CO2 variability (varETCO2), over 20 breaths. Using these variables, three patterns of ventilation are postulated: (a) few incomplete expirations (IncExp < 2) and small varETCO2; (b) a variable number of incomplete expirations (2 ≤ IncExp ≤ 18) and large varETCO2; and (c) a large number of incomplete expirations (IncExp > 18) and small varETCO2. IncExp and varETCO2 were calculated from data describing respiratory flow and CO2 signals in 11 patients mechanically ventilated at 5 levels of pressure support. Data analysis showed that the three patterns presented systematically in the data, with periods of IncExp < 2 or IncExp > 18 having significantly lower variability in end-tidal CO2 than periods with 2 ≤ IncExp ≤ 18 (p < 0.05). It was also shown that sudden change in IncExp from either IncExp < 2 or IncExp > 18 to 2 ≤ IncExp ≤ 18 results in significant, rapid, change in the variability of end-tidal CO2 p < 0.05. This study illustrates that systematic patterns of expiratory flow and end-tidal CO2 are present in patients in supported mechanical ventilation, and that changes between these patterns can be identified. Further studies are required to see if these patterns characterize dynamic hyperinflation. If so, then their combination may provide a useful addition to understanding the patient at the bedside.


Subject(s)
Capnography/methods , Carbon Dioxide/analysis , Exhalation , Respiration, Artificial , Respiration , Capnography/instrumentation , Humans , Lung/physiology , Positive-Pressure Respiration , Positive-Pressure Respiration, Intrinsic , Reproducibility of Results , Tidal Volume , Time Factors
8.
Br J Anaesth ; 116(6): 855-61, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27199317

ABSTRACT

BACKGROUND: General anaesthesia decreases pulmonary compliance and increases pulmonary shunt due to the development of atelectasis. The presence of capnoperitoneum during laparoscopic surgery may further decrease functional residual capacity, promoting an increased amount of atelectasis compared with laparotomy. The aim of this study was to evaluate the effects of different levels of positive end-expiratory pressure (PEEP) in both types of surgery and to investigate whether higher levels of PEEP should be used during laparoscopic surgery. METHODS: This prospective observational study included 52 patients undergoing either laparotomy or laparoscopic surgery. Three levels of PEEP were applied in random order: (1) zero (ZEEP), (2) 5 cmH2O and (3) 10 cmH2O. Pulmonary shunt and ventilation/perfusion mismatch were assessed by the automatic lung parameter estimator system. RESULTS: Pulmonary shunt was similar in both groups. However, in laparotomy, a PEEP of 5 cmH2O significantly decreased shunt when compared with ZEEP (12 vs 6%; P=0.001), with additional PEEP having no further effect. In laparoscopic surgery, a significant reduction in shunt (13 vs 6%; P=0.001) was obtained only at a PEEP of 10 cmH2O. Although laparoscopic surgery was associated with a lower pulmonary compliance, increasing levels of PEEP were able to ameliorate it in both groups. CONCLUSION: Both surgeries have similar negative effects on pulmonary shunt, while the presence of capnoperitoneum reduced only the pulmonary compliance. It appears that a more aggressive PEEP level is required to reduce shunt and to maximize compliance in case of laparoscopic surgery.


Subject(s)
Abdomen/surgery , Lung Compliance , Positive-Pressure Respiration/adverse effects , Aged , Anesthesia, General , Female , Humans , Intraoperative Complications/prevention & control , Laparoscopy/methods , Laparoscopy/standards , Laparotomy , Male , Middle Aged , Prospective Studies , Pulmonary Atelectasis/prevention & control , Respiration, Artificial
9.
Eur Rev Med Pharmacol Sci ; 19(14): 2689-96, 2015.
Article in English | MEDLINE | ID: mdl-26221901

ABSTRACT

OBJECTIVE: The many published studies on the effects of the transfusion of stored red blood cells on clinical outcomes yielded discordant results. Therefore, we chose to study patients with severe trauma. The clinical outcomes considered included in-hospital mortality, the occurrence of sepsis, length of stay in intensive care unit and in hospital, and days of mechanical ventilation. PATIENTS AND METHODS: We selected all patients with traumatic injury, who received at least 2 red cell units in the first day of admission. Patients were divided into two groups: those who had received fresh red cells only (fresh group) and those who had received at least one "old" red cell unit (old group). The red cells were considered fresh if they had been stored <14 days. RESULTS: The fresh and old groups included 376 and 321 patients, respectively. Baseline demographic and clinical characteristics were comparable between the groups. However, old group received more red cell and plasma units during whole hospital stay (red cells: 11 ± 7 vs 6 ± 4, p < 0.001; plasma: 7 [0-9] vs 3 [0-6]). Among outcomes, only length of stay in intensive care unit (old vs fresh: 18 ± 9 vs 12 ± 8 days, p < 0.001) and in hospital (77 ± 35 vs 45 ± 30 days, p < 0.001) differed significantly between groups. The association remained statistically significant in a multivariate analysis including known confounding factors. CONCLUSIONS: Patients with major trauma transfused with old (≥14 days) red cells had a longer length of stay in intensive care unit and in hospital, without any difference in mortality, occurence of sepsis or days of mechanical ventilation.


Subject(s)
Blood Banking/methods , Critical Illness/therapy , Erythrocyte Transfusion/methods , Multiple Trauma/therapy , Adult , Aged , Blood Banks/trends , Critical Illness/mortality , Erythrocyte Count/methods , Erythrocyte Transfusion/mortality , Erythrocyte Transfusion/trends , Erythrocytes/physiology , Female , Hospital Mortality/trends , Humans , Intensive Care Units/trends , Length of Stay/trends , Male , Middle Aged , Multiple Trauma/mortality , Retrospective Studies
10.
Minerva Anestesiol ; 81(1): 33-8, 2015 Jan.
Article in English | MEDLINE | ID: mdl-24861720

ABSTRACT

BACKGROUND: Maximal inspiratory pressure (MIP) can help to evaluate inspiratory muscle strength. However its determination in ventilated patients is cumbersome and needs special equipment. We hypothesized that MIP could be obtained by using the expiratory hold knob of the ventilator. The aim of this study was to verify whether: 1) the end expiratory occlusion technique can be used for MIP determination; and 2) if this technique provides different results compared to those obtained by the traditional method of MIP calculation. METHODS: We studied 23 consecutive patients undergoing mechanical ventilation for acute respiratory failure. The MIP was determined by two different methods, both based on occluding the airway for 20 seconds. This occlusion was obtained either by pressing the expiratory hold knob of the ventilator; or by detaching the patient from the ventilator circuit and using a noiseless pneumatic shutter placed on the inspiratory line of a two-way valve that allows expiration but prevents inspiration. RESULTS: The average values of MIP obtained by using either the hold knob of the ventilator or the noiseless pneumatic shutter were -46±14 cmH2O and -56±13 cmH2O, respectively. The linear regression analysis showed a significant correlation between MIPVent and MIPOcc (r2=0.95), although the Bland- Altman analysis revealed that they are not clinically comparable. CONCLUSION: MIP can be easily determined at the bedside by pressing the expiratory hold knob of ventilator. However, MIPVent and MIPOcc are different in terms of absolute value probably because they were determined at diverse lung volume.


Subject(s)
Maximal Respiratory Pressures , Respiration, Artificial/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Muscle Strength , Prospective Studies , Respiratory Insufficiency/therapy , Respiratory Muscles , Ventilators, Mechanical
11.
Eur Rev Med Pharmacol Sci ; 17(23): 3229-36, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24338466

ABSTRACT

BACKGROUND: In spinal anaesthesia for a Caesarean delivery, it is important to limit anaesthesia only at the surgical area, and to resolve fast motor block. We compared the intraoperative effectiveness, hemodynamic effects, anaesthetic recovery times and patients satisfaction after isobaric levobupivacaine (L) 0.25% versus L0.50% spinal anaesthesia during elective Caesarean deliveries performed with the Stark technique. PATIENTS AND METHODS: In this double-blinded prospective study, seventy women undergoing elective caesarean delivery were randomized to receive either intrathecal 7.5 mg Levobupivacaine 0.25% plus sufentanil 2.5 µg (Group L0.25), or intrathecal 7.5 mg L 0.50% plus sufentanil 2.5 µg (GroupControl). The onset time, duration of anaesthesia, analgesia and sensory and motor block and hemodynamic parameters were measured from the beginning of spinal anaesthesia until four hours after spinal anaesthesia (T240). RESULTS: Onset time, duration of anaesthesia and haemodynamic variations were similar in the two groups. No patients required general anesthesia to complete surgery. Motor block vanished faster in Group L0.25 as compared with GroupControl (p < .01). The cephalad spread of the 0.50% solution was higher than that of the 0.25% solution: no patient in Group L0.25 experienced paresthesia of the upper limbs vs 14% in GroupControl (p < .05). In GroupControl anaesthesia reached the dermatome T1 in 15% of cases. Maternal and surgeon satisfaction was good in every patient. CONCLUSIONS: Levobupivacaine 7.5 milligrams at 0.25% may be used as a suitable alternative to L 0.50% for spinal anaesthesia for caesarean deliveris with the Stark technique with good maternal satisfaction. In Group L0.25 a lower appearance of nausea and hypotension were observed and motor and sensitive block developed and diminished faster while no clinically significant differences in hemodynamic behavior was observed between groups.


Subject(s)
Anesthesia Recovery Period , Anesthesia, Epidural/methods , Anesthesia, Obstetrical/methods , Anesthesia, Spinal/methods , Anesthetics, Local/administration & dosage , Bupivacaine/analogs & derivatives , Cesarean Section , Adult , Analysis of Variance , Anesthetics, Local/adverse effects , Bupivacaine/administration & dosage , Bupivacaine/adverse effects , Chi-Square Distribution , Double-Blind Method , Elective Surgical Procedures , Female , Hemodynamics/drug effects , Humans , Infusions, Spinal , Italy , Levobupivacaine , Motor Activity/drug effects , Patient Satisfaction , Pregnancy , Prospective Studies , Time Factors , Treatment Outcome
13.
J Microsc ; 229(Pt 2): 377-83, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18304100

ABSTRACT

We demonstrate that tapered optical fibre probes can be easily modified in the taper cone to realize an electric dipole producing a well-defined near-field polarized light. This novel structure is made of a Short-cut Double C-shaped probe design combined to the usual full metal coating near the tapered end of the fibre. Hence, the cone at the apex of the probe is excited by an equivalent dipole whose spatial orientation is dictated by the probe geometry, regardless the polarization state of the incoming light. Properties and performances of such a configuration are first predicted by a finite-difference time domain simulation, showing that the near field coming out from the probe is linearly polarized. Following this novel design, a probe prototype is manufactured and tested. Its measured polar diagram confirms the polarization maintenance property in the near field.

14.
Micron ; 37(6): 533-7, 2006.
Article in English | MEDLINE | ID: mdl-16487714

ABSTRACT

Iridescent organic films consisting of quasi-parallel wire-like microstructures are grown by castings from ethanol solutions containing mixtures of aluminium-tris-hydroxyquinoline and 1,10-phenanthroline. Spectrophotometric measurements carried out in the ultraviolet-visible range indicate that the microstructured films have angular-dependent optical behaviour, which is motivated by a refractive-index modulation over dimensions that are comparable to visible-light wavelengths. According to the results of investigations carried out by means of optical microscopy, atomic force microscopy (AFM), and scanning near-field optical microscopy (SNOM), the refractive-index modulation originates from a thickness modulation and a phase separation that occurs as the aluminium-tris-hydroxyquinoline and phenanthroline co-crystallize, with the former material being arranged to form a green luminescent pattern on the top of the latter one.

15.
Sarcoidosis Vasc Diffuse Lung Dis ; 18(1): 85-90, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11354553

ABSTRACT

A 53-year-old man was evaluated for snoring, dysphagia for solid foods and difficulty of breathing and a polysomnographic recording was consistent with a diagnosis of obstructive sleep apnoea syndrome (OSAS). A flexible fiberoptic bronchoscopy (FFB) showed the presence of a nodular lesion of the posterior ventral surface of the tongue strictly connected to the left lateral border of the epiglottis. The biopsy specimen taken from the lesion was consistent with sarcoidosis. No involvement of pulmonary parenchyma, lymph nodes or other organs was recognized. After two months of steroid treatment, symptoms disappeared and resolution of the nodular lesion at the FFB and normalization of the polysomnographic recording were observed. This is the first report of orolaryngeal sarcoidosis associated with OSAS as the only clinical presentation of the disease.


Subject(s)
Laryngeal Diseases/complications , Sarcoidosis/complications , Sleep Apnea, Obstructive/etiology , Bronchoscopy , Deglutition Disorders/etiology , Dyspnea/etiology , Humans , Laryngeal Diseases/diagnosis , Laryngeal Diseases/pathology , Male , Middle Aged , Polysomnography , Sarcoidosis/diagnosis , Sarcoidosis/pathology , Steroids/therapeutic use
16.
Monaldi Arch Chest Dis ; 55(5): 371-4, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11213372

ABSTRACT

The indirect estimate of oxyhaemoglobin saturation (Sa,O2) is largely used in the management of patients with respiratory failure. The aim of this study was to evaluate the accuracy of the Sa,O2 values calculated by using both the Siggaard-Andersen (SA) and the Severinghaus (SE) equation, in comparison with the real Sa,O2 values measured by a co-oximeter. A total of 558 arterial blood samples were analysed. On average, only a slight overestimation was found for Sa,O2 estimated by the SA (2.35 +/- 5.75%) and the SE (2.37 +/- 5.65%) equations in comparison with the real values. However, a difference higher than 5% between estimated and real Sa,O2 values was demonstrated in more than 20% of the blood samples evaluated. This difference was higher than 10% in 9% of the samples, with similar results obtained with the two equations. The discrepancy between real and estimated values, probably due, at least in part, to errors in measurement of arterial oxygen tension (Pa,O2) and pH, was maximally evident for Sa,O2 values lower than 70%. An indirect estimate of Sa,O2 is not homogeneously accurate, and the clinical consequence of this finding might be especially dangerous in monitoring patients with severe respiratory failure.


Subject(s)
Oxyhemoglobins/analysis , Respiratory Insufficiency/blood , Humans
17.
Respir Med ; 94(12): 1171-6, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11192952

ABSTRACT

The aim of this study was to evaluate the predictive value of preoperative spirometric and arterial gas data on severe pulmonary complications (PC) after elective abdominal surgery. We retrospectively studied 480 patients, 254 males and 226 females, mean (SD) age 63 (11) years, at risk for PC according to standardized criteria, who underwent laparotomy for resection of gallbladder for gallstones (44% of patients), resection of colon, rectum or stomach for malignant tumours (37%), and other abdominal surgery (19%). The overall incidence of postoperative PC was 18%. In a logistic regression analysis adjusted for smoking habit and clinical history of chronic bronchitis, FEV1<61% of predicted [odds ratio (OR)=16.86, 95% confidence interval (95%CI)=5.62-50.58] and PaO2<9.33 kPa (OR=6.42, 95%CI=2.48-16.61) were the main determinants of PC. Ischaemic heart disease (OR=3.44, 95%CI=1.08-10.93), operation for malignant tumours (OR=3.24, 95%CI=1.75-6.00) and age (OR=1.04, 95%CI=1.00-1.08) were also independent predictors of PC. Patients with moderate-to-severe airway obstruction combined with hypoxaemia had a significant higher risk of PC in comparison with patients with a normal respiratory pattern. Taking into account age, type of operation, and comorbidity, a preoperative respiratory functional assessment could be useful in identifying an increased risk of major PC in selected patients.


Subject(s)
Abdomen/surgery , Lung Diseases/diagnosis , Postoperative Complications/diagnosis , Blood Gas Analysis , Body Mass Index , Female , Humans , Length of Stay , Lung Diseases/blood , Lung Diseases/etiology , Male , Middle Aged , Postoperative Complications/etiology , Predictive Value of Tests , Regression Analysis , Retrospective Studies , Risk Factors , Smoking , Spirometry
18.
Biotechnol Bioeng ; 62(5): 554-61, 1999 Mar 05.
Article in English | MEDLINE | ID: mdl-10099564

ABSTRACT

The activity of different lipase (from Pseudomonas cepacia) forms, such as crude powder (crude PC), purified and lyophilized with PEG (PEG + PC), covalently linked to PEG (PEG-PC), cross-linked enzyme crystals (CLEC-PC), and immobilized in Sol-Gel-AK (Sol-Gel-AK-PC) was determined, at various water activities (aw), in carbon tetrachloride, benzene and 1,4-dioxane. The reaction of vinyl butyrate with 1-octanol was employed as a model and both transesterification (formation of 1-octyl butyrate) and hydrolysis (formation of butyric acid from vinyl butyrate) rates were determined. Both rates depended on the lipase form, solvent employed, and aw value. Hydrolysis rates always increased as a function of aw, while the optimum of aw for transesterification depended on the enzyme form and nature of the solvent. At proper aw, some lipase forms such as PEG + PC, PEG-PC, and Sol-Gel-AK-PC had a total activity in organic solvents (transesterification plus hydrolysis) which was close to (39 and 48%) or even higher than (130%) that displayed by the same amount of lipase protein in the hydrolysis of tributyrin-one of the substrates most commonly used as standard for the assay of lipase activity-in aqueous buffer. Instead, CLEC-PC and crude PC were much less active in organic solvents (2 and 12%) than in buffer. The results suggest that enzyme dispersion and/or proper enzyme conformation (favored by interaction with PEG or the hydrophobic Sol-Gel-AK matrix) are essential for the expression of high lipase activity in organic media.


Subject(s)
Burkholderia cepacia/enzymology , Lipase/isolation & purification , Biotechnology , Buffers , Catalysis , Esterification , Hydrolysis , Lipase/metabolism , Polyethylene Glycols , Solvents , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...