Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Article in English | MEDLINE | ID: mdl-38994529

ABSTRACT

Background: This study aimed to establish an equation for calculating cup ante-inclination (AI) from radiographic cup inclination and anteversion, to validate this equation in a total hip arthroplasty (THA) cohort, and to test whether achieving previously described radiographic cup inclination and anteversion targets would also satisfy sagittal cup AI targets. Methods: A mathematical equation linking cup AI, radiographic inclination (RI), and anteversion (RA) was determined: tan(AI) = tan(RA)/cos(RI). Supine and standing anteroposterior and lateral radiographs of 440 consecutive THAs were assessed to measure cup RI and RA and spinopelvic parameters, including cup AI, using a validated software tool. Whether orientation within previously defined RI and RA targets was associated with achieving the AI target and satisfying the sagittal component orientation (combined sagittal index, 205° to 245°) was tested. Results: The cups in the THA cohort had a measured mean inclination (and standard deviation) of 43° ± 7°, anteversion of 26° ± 9°, and AI of 34° ± 10°. The calculated cup AI was 34° ± 12°. A strong correlation existed between measured and calculated AI (r = 0.75; p < 0.001), with a mean error of 0° ± 8°. The inclination and anteversion targets were both satisfied in 194 (44.1%) to 330 (75.0%) of the cases, depending on the safe zone targets that were used, and 311 cases (70.7%) satisfied the AI target. Only 125 (28.4%) to 233 (53.0%) of the cases satisfied the AI target as well as the inclination and anteversion targets. Satisfying inclination and anteversion targets was not associated with increased chances of satisfying the AI target. Conclusions: Achieving optimal cup inclination and anteversion does not ensure optimal orientation in the sagittal plane. The equation and nomograms provided can be used to determine and visualize how the 2 planes used for evaluating the cup orientation and the pertinent angles relate, potentially aiding in preoperative planning.

2.
J Arthroplasty ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38897260

ABSTRACT

BACKGROUND: Accurate hip reconstruction is associated with improved biomechanical behavior following total hip arthroplasty (THA). However, whether this is associated with improved patient-reported outcome measures (PROs) is unknown. HYPOTHESIS/PURPOSE: This study aimed to: 1) Describe the ability to reconstruct coronal geometry during THA without advanced technology; 2) Assess whether restoration of global offset (GO) and leg length (LL) is associated with improved PROs; and 3) Investigate whether increased femoral offset (FO) to compensate for reduced acetabular offset (AO) influences PROs. METHOD: This was a prospective, multi-center, consecutive cohort study of 500 patients treated with primary THA without robotics or navigation. The Oxford Hip Score (OHS) was obtained pre-operatively and at 1-year follow-up. Supine anteroposterior (AP) pelvic radiographs were analyzed to determine AO, FO, GO, and LL relative to the native contralateral side. Contour plots for ΔOHS based on ΔLL and ΔGO were created, and ΔOHS was calculated within and outside various ranges (± 2.5, ± 5, or ± 10 mm). RESULTS: The mean GO and LL differences between sides were 0 ± 7 mm and 0 ± 8 mm, respectively. In the operated hip, mean FO increased to 3 ± 6 mm (range, -16 to 27), while AO decreased to 2 ± 4 mm (range, -17 to 10). The contour graph for ± 2.5 mm zones showed the best outcomes (ΔOHS > 25) with GO and LL centered on 0 ± 2.5 mm (P < 0.01). However, only 10% achieved such reconstruction. When GO and LL differences were within ± 10 mm, ΔOHS was superior when both AO and FO were within ± 5 mm (mean: 24 ± 10; range, -5 to 40) compared to when FO was above 5 mm to compensate for a reduction in AO (mean: 22 ± 11; range, -10 to 46; P = 0.040). DISCUSSION: Mean GO and LL reconstruction were both 0 mm, with a precision of 7 and 8 mm, respectively, using manual techniques. The PROs were associated with biomechanical reconstruction, and the best clinical improvement can be expected when GO and LL differences are both within 2.5 mm. Maintenance of AO is important, as compensation by increasing FO is associated with inferior OHS.

3.
Clin Orthop Relat Res ; 482(2): 259-274, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37498285

ABSTRACT

BACKGROUND: Acetabular morphology is an important determinant of hip biomechanics. To identify features of acetabular morphology that may be associated with the development of hip symptoms while accounting for spinopelvic characteristics, one needs to determine acetabular characteristics in a group of individuals older than 45 years without symptoms or signs of osteoarthritis. Previous studies have used patients with unknown physical status to define morphological thresholds to guide management. QUESTIONS/PURPOSES: (1) To determine acetabular morphological characteristics in males and females between 45 and 60 years old with a high Oxford hip score (OHS) and no signs of osteoarthritis; (2) to compare these characteristics with those of symptomatic hip patients treated with hip arthroscopy or periacetabular osteotomy (PAO) for various kinds of hip pathology (dysplasia, retroversion, and cam femoroacetabular impingement); and (3) to assess which radiographic or CT parameters most accurately differentiate between patients who had symptomatic hips and those who did not, and thus, define thresholds that can guide management. METHODS: Between January 2018 and December 2018, 1358 patients underwent an abdominopelvic CT scan in our institution for nonorthopaedic conditions. Of those, we considered 5% (73) of patients as potentially eligible as controls based on the absence of major hip osteoarthritis, trauma, or deformity. Patients were excluded if their OHS was 43 or less (2% [ 28 ]), if they had a PROMIS less than 50 (1% [ 18 ]), or their Tönnis score was higher than 1 (0.4% [ 6 ]). Another eight patients were excluded because of insufficient datasets. After randomly selecting one side for each control, 40 hips were left for analysis (age 55 ± 5 years; 48% [19 of 40] were in females). In this comparative study, this asymptomatic group was compared with a group of patients treated with hip arthroscopy or PAO. Between January 2013 and December 2020, 221 hips underwent hip preservation surgery. Of those, eight were excluded because of previous pelvic surgery, and 102 because of insufficient CT scans. One side was randomly selected in patients who underwent bilateral procedure, leaving 48% (107 of 221) of hips for analysis (age 31 ± 8 years; 54% [58 of 107] were in females). Detailed radiographic and CT assessments (including segmentation) were performed to determine acetabular (depth, cartilage coverage, subtended angles, anteversion, and inclination) and spinopelvic (pelvic tilt and incidence) parameters. Receiver operating characteristics (ROC) analysis was used to assess diagnostic accuracy and determine which morphological parameters (and their threshold) differentiate most accurately between symptomatic patients and asymptomatic controls. RESULTS: Acetabular morphology in asymptomatic hips was characterized by a mean depth of 22 ± 2 mm, with an articular cartilage surface of 2619 ± 415 mm 2 , covering 70% ± 6% of the articular surface, a mean acetabular inclination of 48° ± 6°, and a minimal difference between anatomical (24° ± 7°) and functional (22° ± 6°) anteversion. Patients with symptomatic hips generally had less acetabular depth (20 ± 4 mm versus 22 ± 2 mm, mean difference 3 mm [95% CI 1 to 4]; p < 0.001). Hips with dysplasia (67% ± 5% versus 70% ± 6%, mean difference 6% [95% CI 0% to 12%]; p = 0.03) or retroversion (67% ± 5% versus 70% ± 6%, mean difference 6% [95% CI 1% to 12%]; p = 0.04) had a slightly lower relative cartilage area compared with asymptomatic hips. There was no difference in acetabular inclination (48° ± 6° versus 47° ± 7°, mean difference 0.5° [95% CI -2° to 3°]; p = 0.35), but asymptomatic hips had higher anatomic anteversion (24° ± 7° versus 19° ± 8°, mean difference 6° [95% CI 3° to 9°]; p < 0.001) and functional anteversion (22° ± 6° versus 13°± 9°, mean difference 9° [95% CI 6° to 12°]; p < 0.001). Subtended angles were higher in asymptomatic at 105° (124° ± 7° versus 114° ± 12°, mean difference 11° [95% CI 3° to 17°]; p < 0.001), 135° (122° ± 9° versus 111° ± 12°, mean difference 10° [95% CI 2° to 15°]; p < 0.001), and 165° (112° ± 9° versus 102° ± 11°, mean difference 10° [95% CI 2° to 14°]; p < 0.001) around the acetabular clockface. Symptomatic hips had a lower pelvic tilt (8° ± 8° versus 11° ± 5°, mean difference 3° [95% CI 1° to 5°]; p = 0.007). The posterior wall index had the highest discriminatory ability of all measured parameters, with a cutoff value of less than 0.9 (area under the curve [AUC] 0.84 [95% CI 0.76 to 0.91]) for a symptomatic acetabulum (sensitivity 72%, specificity 78%). Diagnostically useful parameters on CT scan to differentiate between symptomatic and asymptomatic hips were acetabular depth less than 22 mm (AUC 0.74 [95% CI 0.66 to 0.83]) and functional anteversion less than 19° (AUC 0.79 [95% CI 0.72 to 0.87]). Subtended angles with the highest accuracy to differentiate between symptomatic and asymptomatic hips were those at 105° (AUC 0.76 [95% CI 0.65 to 0.88]), 135° (AUC 0.78 [95% CI 0.70 to 0.86]), and 165° (AUC 0.77 [95% CI 0.69 to 0.85]) of the acetabular clockface. CONCLUSION: An anatomical and functional acetabular anteversion of 24° and 22°, with a pelvic tilt of 10°, increases the acetabular opening and allows for more impingement-free flexion while providing sufficient posterosuperior coverage for loading. Hips with lower anteversion or a larger difference between anatomic and functional anteversion were more likely to be symptomatic. The importance of sufficient posterior coverage was also illustrated by the posterior wall indices and subtended angles at 105°, 135°, and 165° of the acetabular clockface having a high discriminatory ability to differentiate between symptomatic and asymptomatic hips. Future research should confirm whether integrating these parameters when selecting patients for hip preservation procedures can improve postoperative outcomes.Level of Evidence Level III, prognostic study.


Subject(s)
Femoracetabular Impingement , Osteoarthritis, Hip , Female , Humans , Male , Middle Aged , Acetabulum/diagnostic imaging , Acetabulum/surgery , Femoracetabular Impingement/diagnostic imaging , Femoracetabular Impingement/surgery , Hip Joint/diagnostic imaging , Hip Joint/surgery , Osteoarthritis, Hip/diagnostic imaging , Osteoarthritis, Hip/surgery
4.
Clin Biomech (Bristol, Avon) ; 101: 105848, 2023 01.
Article in English | MEDLINE | ID: mdl-36512944

ABSTRACT

BACKGROUND: During primary total hip arthroplasty, intra-operative calcar fractures have been historically treated with cerclage wires. However, interfragmentary screw fixation technique can possibly achieve the same results with technical advantages. The aim of this biomechanical study was to assess stability of calcar fractures fixed using interfragmentary screw technique compared to a traditional cerclage system specifically in context of total hip arthroplasty. METHODS: Thirty-two periprosthetic fractures were reduced using either a single cerclage cable or an intracortical positional screw perpendicular to the fracture line. Axial and torsional load testing was terminated after experimental model failure. FINDINGS: No significant difference was obtained for all output parameters when comparing cerclage wires versus interfragmentary screw fixation respectively. Load at failure: 8043 ± 712 N vs 7425 ± 854 N (p = 0.115). Load at calcar fracture propagation: 6240 ± 2207 N versus 6220 ± 966 N (p = 0.668). Maximum stiffness before failure: 617 ± 115 N/mm vs 839 ± 175 N/mm (p = 0.100) and stiffness at calcar fracture propagation reached 771 ± 153 Nmm vs 886 ± 129 N/mm (p = 0.197). Torque to failure levels obtained were 59.4 ± 7.1 N*m vs 60.9 ± 12.0 N*m (p = 0.908). Torque to calcar fracture propagation, 51.6 ± 6.1 N*m vs 48.5 ± 9.8 N*m (p = 0.298). Torsional stiffness at failure, 0.38 ± 0.03 N*m\deg. vs 0.43 ± 0.13 N*m\deg. (p = 0.465). Torsional stiffness at calcar fracture propagation were 0.37 ± 0.03 N*m\deg. vs 0.45 ± 0.17 N*m\deg. (p = 0.462). INTERPRETATION: The strength of fixation and stability of the implant were similar for both techniques. In the synthetic bone model tested, using an interfragmentary screw conveyed similar stability to the constructs in the management of an intra-operative medial calcar fractures. Thus, potentially giving surgeons an alternative option for intraoperative fracture fixation during primary total hip arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Humans , Arthroplasty, Replacement, Hip/methods , Femoral Fractures/surgery , Fracture Fixation, Internal/methods , Bone Wires , Bone Screws , Biomechanical Phenomena , Bone Plates
5.
Am J Sports Med ; 50(10): 2637-2646, 2022 08.
Article in English | MEDLINE | ID: mdl-35867779

ABSTRACT

BACKGROUND: Validated software tools (Clinical Graphics [CG] and Hip2Norm) permit measurement of the percentage of femoral head coverage (%FHC), which aids in morphological classification and prediction of outcome after hip preservation surgery. PURPOSE: (1) To assess whether acetabular parameter measurements determined from 2 commonly used software systems are comparable. (2) To determine which parameters influence the correlation or differences between software outputs and measurements. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: The study included 69 patients (90 hips) who underwent periacetabular osteotomy and had comprehensive preoperative imaging available. Lateral center-edge angle (LCEA), acetabular index (AI), and %FHC were determined using 3-dimensional computed tomography (CT) measurements by CG and Hip2Norm software. Images of 18 pelvises were segmented to determine spinopelvic parameters and subtended acetabular angles. Between-group measurements were compared using correlation coefficients and Bland-Altman analyses. The difference in the outputs of the 2 programs was defined as delta (Δ). Radiographic parameters were tested to assess whether they were responsible for differences in %FHC between software programs. RESULTS: Strong correlations between LCEA (ρ = 0.862) and AI (ρ = 0.825) measurements were seen between the Hip2Norm and CG programs. However, weak correlation was seen in the estimate of %FHC (ρ = 0.358), with the presence of a systematic error. Hip2Norm consistently produced lower anterior, posterior, and total %FHC values than CG. The %FHC determined by CG, but not Hip2Norm, correlated with acetabular subtended angles (P < .05). Pelvic tilt measured on CT did not correlate with pelvic tilt estimated by Hip2Norm (P = .56), and ΔPelvicTilt strongly correlated with the difference in %FHC by the 2 software programs (ρ = 0.63; P = .005), pelvic incidence (ρ = 0.73; P < .001), and pelvic tilt (ρ = -0.91; P < .001) as per CT. CONCLUSION: The correlation of %FHC between Hip2Norm and CG was weak (ρ = 0.358). The difference in measurements of %FHC correlated with ΔPelvicTilt. The %FHC determined by CG strongly correlated with the segmented acetabular subtended angles and thus more likely reflected true values. Hip preservation surgeons should be aware of these measurement differences because %FHC is important in the diagnosis and prognosis of acetabular dysplasia.


Subject(s)
Hip Dislocation, Congenital , Hip Dislocation , Acetabulum/diagnostic imaging , Acetabulum/surgery , Cohort Studies , Hip Dislocation/diagnostic imaging , Hip Dislocation/surgery , Hip Dislocation, Congenital/surgery , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Retrospective Studies , Software
6.
Orthop J Sports Med ; 9(10): 23259671211030495, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34708135

ABSTRACT

BACKGROUND: In addition to the relative size of the acetabular rim and how the pelvis is positioned in space, the plane in which the acetabular version is calculated also affects its measurement. PURPOSE: To determine the relative contribution of pelvic and acetabular characteristics on morphological version (measured relative to the anterior pelvic plane angle [APPA]) and functional version (measured relative to the horizontal table). STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: Included were 50 acetabular dysplasia patients and 109 asymptomatic controls. Using image analysis software, morphological parameters of the pelvis and acetabulum were determined from 2-dimensional computed topography: pelvic incidence, pelvic tilt angle, sacral slope, APPA, morphological and functional acetabular versions, and subtended angles (measure of acetabular rim prominence relative to the femoral head center) around the acetabular clockface in 30° increments. Correlation and multivariable regression analyses were performed with morphological and functional version as dependent variables and spinopelvic and acetabular parameters as independent variables. RESULTS: Morphological version was moderately associated with differences between anterior and posterior subtended angles (R = 0.68 [P < .001] and R = 0.57 [P < .001] for differences at 165° and 15° and 135° and 45°, respectively). Functional version was moderately associated with pelvic tilt angle (R = 0.56; P <.001) and the difference in subtended angles between anterior and posterior rims (R = 0.61 [P < .001] and R = 0.50 [P < .001] for differences at 165° and 15° and 135° and 45°, respectively). Multivariate analysis revealed a good model for predicting morphological version (R 2 = 0.44; P < .01) and functional version (R 2 = 0.58; P < .01). Subtended angle difference between 165° and 15° (B = 0.36 [95% CI, 0.24-0.49]; P < .001) was most strongly related to morphological version, and pelvic tilt angle (B = 0.57 [95% CI, 0.46-0.68]; P < .001) was most strongly related to functional version. CONCLUSION: Functional acetabular version was influenced most strongly by pelvic tilt angle rather than the relative prominence of the acetabular rims. Before determining surgical management for version abnormalities, it would be prudent to assess pelvic mobility and characteristics in different functional positions. In patients with minimal pelvic tilt change dynamically, corrective osteotomy would be the treatment of choice to improve functional version.

7.
J Biophotonics ; 14(1): e202000289, 2021 01.
Article in English | MEDLINE | ID: mdl-32924290

ABSTRACT

Articular cartilage posesses unique material properties due to a complex depth-dependent composition of sub-components. Raman spectroscopy has proven valuable in quantifying this composition through cartilage cross-sections. However, cross-sectioning requires tissue destruction and is not practical in situ. In this work, Raman spectroscopy-based multivariate curve resolution (MCR) was employed in porcine cartilage samples (n = 12) to measure collagen, glycosaminoglycan, and water distributions through the surface for the first time; these were compared against cross-section standards. Through the surface Raman measurements proved reliable in predicting composition distribution up to a depth of approximately 0.5 mm. A fructose-based optical clearing agent (OCA) was also used in an attempt to further improve depth of resolution of this measurement method. However, it did not; mainly due to a high-spectral overlap with the Raman spectra of main cartilage sub-components. This measurement technique potentially could be used in situ, to better understand the etiology of joint diseases such as osteoarthritis (OA).


Subject(s)
Cartilage, Articular , Osteoarthritis , Animals , Collagen , Multivariate Analysis , Spectrum Analysis, Raman , Swine
8.
J Assist Reprod Genet ; 37(6): 1303-1310, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32253538

ABSTRACT

The recent paper in JAMA alleging that frozen embryo transfer causes twice the risk of childhood cancer in the offspring is an excellent example of the erroneous use of statistical tests (and the misinterpretation of p value) that is common in much of the medical literature, even in very high impact journals. These myths backed by misleading statements of "statistical significance" can cause far-reaching harm to patients and doctors who might not understand the pitfalls of specious statistical testing.


Subject(s)
Data Interpretation, Statistical , Embryo Transfer/adverse effects , Neoplasms/epidemiology , Child , Embryo Transfer/statistics & numerical data , Female , Humans , Neoplasms/etiology , Risk Factors
9.
Eur Radiol ; 30(8): 4695-4704, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32248366

ABSTRACT

OBJECTIVES: The purpose of this study was to determine if the CT texture profile of acetabular subchondral bone differs between normal, asymptomatic cam-positive, and symptomatic cam-FAI hips. In addition, the utility of texture analysis to discriminate between the three hip statuses was explored using a machine learning approach. METHODS: IRB-approved, case-control study analyzing CT images in subjects with and without cam morphology from August 2010 to December 2013. Sixty-eight subjects were included: 19 normal controls, 26 asymptomatic cam, and 23 symptomatic cam-FAI. Acetabular subchondral bone was contoured on the sagittal oblique CT images using ImageJ ®. 3D histogram texture features (mean, variance, skewness, kurtosis, and percentiles) were evaluated using MaZda software. Groupwise differences were investigated using Kruskal-Wallis tests and Mann-Whitney U tests. Gradient-boosted decision trees were created and trained to discriminate between control and cam-positive hips. RESULTS: Both asymptomatic and symptomatic cam-FAI hips demonstrated significantly higher values of texture variance (p = 0.0007, p < 0.0001), 90th percentile (p = 0.007, p = 0.006), and 99th percentile (p = 0.009, p = 0.009), but significantly lower values of skewness (p = 0.0001, p = 0.0013) and kurtosis (p = 0.0001, p = 0.0001) compared to normal controls. There were no differences in texture profile between asymptomatic cam and symptomatic cam-FAI hips. Machine learning models demonstrated high classification accuracy for discriminating control hips from asymptomatic cam-positive (82%) and symptomatic cam-FAI (86%) hips. CONCLUSIONS: Texture analysis can discriminate between normal and cam-positive hips using conventional descriptive statistics, regression modeling, and machine learning algorithms. It has the potential to become an important tool in compositional analysis of hip subchondral trabecular bone in the context of FAI, and possibly serve as a biomarker of joint degeneration. KEY POINTS: • The CT texture profile of acetabular subchondral bone is significantly different between normal and cam-positive hips. • Texture analysis can detect changes in subchondral bone in asymptomatic cam-positive hips that are equal to that of symptomatic cam-FAI hips. • Texture analysis has the potential to become an important tool in compositional analysis of hip subchondral bone in the context of FAI and may serve as a biomarker in the study of joint physiology and biomechanics.


Subject(s)
Acetabulum/diagnostic imaging , Femoracetabular Impingement/diagnosis , Hip Joint/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Case-Control Studies , Female , Humans , Male , Reproducibility of Results
10.
J Biomech Eng ; 142(5)2020 05 01.
Article in English | MEDLINE | ID: mdl-31825078

ABSTRACT

The main function of articular cartilage is to distribute loads and provide low friction for the opposing surfaces in synovial joints. Biphasic lubrication provided by high fluid load support due to relative motion of the contact surfaces has been widely accepted as the main lubrication mode in diarthrodial joints. However, assessment of chondrocyte response to mechanical loads typically employed nonphysiological uniaxial loads with static contact area. This study aimed to introduce a more physiologically relevant loading protocol for in vitro mechanobiological testing of cartilage explants. Finite element analysis was conducted to examine the biomechanical response of cartilage to two different loading regimes, biaxial loading, that permits migrating contact area, and unconfined uniaxial cyclic compression, traditionally used in mechanobiological experiments. Results predicted in this study showed that continuous tissue rehydration provided by relative surface motion maintained constant fluid pressure and tissue strains through the simulation. On the contrary, due to rapid tissue consolidation predicted in cyclic compression simulation, fluid pressure and transverse strain were reduced by 19% and 26%, respectively. Furthermore, relative surface motion simulation resulted in depth-dependent distribution of fluid pressure and tissue strains while unconfined uniaxial cyclic compression produced nearly uniform fluid pressure through the depth but higher at the center of the sample. Based on the results obtained from this study and since sliding contact occurs in vivo, this physiological loading mode should be considered in assessing biomechanical and mechanobiological cartilage behavior.


Subject(s)
Cartilage, Articular , Friction , Biomechanical Phenomena , Compressive Strength , Finite Element Analysis , Pressure , Stress, Mechanical
11.
J Hip Preserv Surg ; 5(3): 259-266, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30393553

ABSTRACT

A cam deformity is proposed as a cause of idiopathic osteoarthritis. Increased subchondral bone mineral density (BMD) is associated with this degenerative process of osteoarthritis, and the patient's activity level may contribute to it. Therefore, the correlation between activity level and subchondral BMD in subjects with cam deformity FAI was studied. In this study, 26 asymptomatic cam deformity subjects (Bump) were compared with 18 subjects with a normal alpha angle (Control). Anterosuperior subchondral femoral neck and acetabular rim BMD were measured using quantitative computed tomography. Activity level was determined using the UCLA activity score. The correlation between BMD and UCLA activity were analysed. The result was a significantly higher BMD for Bump subjects in almost all measured sections. The UCLA score of the Bump versus Control subjects were comparable (8.96 versus 8.77, P = 0.740). While the controls showed no correlation between UCLA and BMD, a positive correlation was found for the Bump subjects on several femoral and acetabular impingement locations. These results support the conclusion that mechanical loading causes subchondral stiffening at the anterosuperior head-neck junction of the femur and anterosuperior acetabular rim. The absence of a correlation between BMD versus UCLA in the Controls supports the hypothesis that activity level may serve as a predictor for higher subchondral BMD in a cam deformity hip joint.

12.
J Orthop Res ; 36(12): 3125-3135, 2018 12.
Article in English | MEDLINE | ID: mdl-30175856

ABSTRACT

This article reviews a body of work performed by the investigators over 9 years that has addressed the significance of cam morphology in the development of hip osteoarthritis (OA). Early hip joint degeneration is a common clinical presentation and preexisting abnormal joint morphology is a risk factor for its development. Interrogating Hill's criteria, we tested whether cam-type femoroacetabular impingement leads to hip OA. Strength of association was identified between cam morphology, reduced range-of-movement, hip pain, and cartilage degeneration. By studying a pediatric population, we were able to characterize the temporality between cam morphology (occurring 1st) and joint degeneration. Using in silico (finite element) and in vivo (imaging biomarkers) studies, we demonstrated the biological plausibility of how a cam deformity can lead to joint degeneration. Furthermore, we were able to show a biological gradient between degree of cam deformity and extent of articular damage. However, not all patients develop joint degeneration and we were able to characterize which factors contribute to this (specificity). Lastly, we were able to show that by removing the cam morphology, one could positively influence the degenerative process (experiment). The findings of this body of work show consistency and coherence with the literature. Furthermore, they illustrate how cam morphology can lead to early joint degeneration analogous to SCFE, dysplasia, and joint mal-reduction post-injury. The findings of this study open new avenues on the association between cam morphology and OA including recommendations for the study, screening, follow-up, and assessment (patient-specific) of individuals with cam morphology in order to prevent early joint degeneration. Statement of significance: By satisfying Hill's criteria, one can deduct that in some individuals, cam morphology is a cause of OA. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3125-3135, 2018.


Subject(s)
Femoracetabular Impingement/pathology , Hip Joint/physiopathology , Osteoarthritis, Hip/etiology , Adolescent , Adult , Bone Density , Child , Female , Femoracetabular Impingement/physiopathology , Hand Strength , Humans , Male , Middle Aged , Range of Motion, Articular , Young Adult
13.
J Orthop Res ; 36(7): 1840-1848, 2018 07.
Article in English | MEDLINE | ID: mdl-29323746

ABSTRACT

Acetabular and spino-pelvic (SP) morphological parameters are important determinants of hip joint dynamics. This prospective study aimed to determine whether acetabular and SP morphological differences exist between hips with and without cam morphology and between symptomatic and asymptomatic hips with cam morphology. A cohort of 67 patients/hips was studied. Hips were either asymptomatic with no cam (Controls, n = 18), symptomatic with cam (n = 26) or asymptomatic with cam (n = 23). CT-based quantitative assessments of femoral, acetabular, pelvic, and spino-pelvic parameters were performed. Measurements were compared between controls and those with a cam deformity, as well as between the three groups. Morphological parameters that were independent predictors of a symptomatic cam were determined using a regression analysis. Hips with cam deformity had slightly smaller subtended angles superior-anteriorly (87° vs. 84°, p = 0.04) and greater pelvic incidence (53° vs. 48°, p = 0.003) compared to controls. Symptomatic cams had greater acetabular version (p < 0.01), greater subtended angles superiorly and superior-posteriorly (p = 0.01), higher pelvic incidence (p = 0.02), greater alpha angles and lower femoral neck-shaft angles compared to asymptomatic cams (p < 0.01) and controls (p < 0.01). The four predictors of symptomatic cam included antero-superior alpha angle, femoral neck-shaft angle, acetabular depth, and pelvic incidence. In conclusion, this study illustrates that symptomatic hips had a greater amount of supero-posterior coverage; which would be the contact area between a radial cam and the acetabulum, when the hip is flexed to 90°. Furthermore, individuals with symptomatic cam morphology had greater PI. Acetabular- and SP parameters should be part of the radiological assessment of femoro-acetabular impingement. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1840-1848, 2018.


Subject(s)
Acetabulum/surgery , Femoracetabular Impingement/physiopathology , Femoracetabular Impingement/surgery , Osteoarthritis, Hip/surgery , Acetabulum/diagnostic imaging , Acetabulum/physiopathology , Adult , Female , Femoracetabular Impingement/diagnostic imaging , Femur/diagnostic imaging , Femur/physiopathology , Femur/surgery , Hip Joint/physiopathology , Humans , Male , Middle Aged , Observer Variation , Osteoarthritis, Hip/diagnostic imaging , Osteoarthritis, Hip/physiopathology , Prospective Studies , ROC Curve , Regression Analysis , Retrospective Studies , Tomography, X-Ray Computed , Young Adult
14.
Med Eng Phys ; 51: 96-103, 2018 01.
Article in English | MEDLINE | ID: mdl-29239748

ABSTRACT

Accurate in-vitro orientation of cadaveric hip joints is challenging due to limited available anatomical landmarks. Published hip joint in-vitro investigations commonly lack details on methods used to achieve reported orientations and the accuracy with which the desired orientation has been achieved. The aim of this study was to develop an accurate method for orienting hip joints with limited anatomical landmarks for in-vitro investigations, and to compare this method against orientation using guiding axes and by visual approximation. The proposed orientation method resulted in orientation angles achieved to within one degree (SD ±â€¯0.58°). For most specimens, orientation using physical tools resulted in errors of ±8° and ±12° in at least one of three orientation angles used to place the femur and pelvis in neutral orientation, respectively. Precision was also worse, with SDs ranging from ±1° to ±5° for orientation angles of femoral specimens and SDs ranging from ±1° to ±8° for pelvic specimens. The error in the orientation angles was worse for orientation by visual approximation and the range of SDs were greater for both the femur and pelvis. Finite element modeling was used to assess the effects of observed orientation errors, on prediction of fracture load. In most cases, the largest error in fracture load among all trials exceeded 30%, relative to a femur oriented without any error in the orientation angles.


Subject(s)
Hip Joint/anatomy & histology , Hip Joint/physiology , Materials Testing/methods , Movement , Cadaver , Finite Element Analysis , Humans , Materials Testing/standards , Reference Standards
15.
J Bone Joint Surg Am ; 99(16): 1373-1381, 2017 Aug 16.
Article in English | MEDLINE | ID: mdl-28816897

ABSTRACT

BACKGROUND: Cam morphology in association with femoroacetabular impingement (FAI) is a recognized cause of hip pain and cartilage damage and proposed as a leading cause of arthritis. The purpose of this study was to analyze the functional and biomechanical effects of the surgical correction of the cam deformity on the degenerative process associated with FAI. METHODS: Ten male patients with a mean age of 34.3 years (range, 23.1 to 46.5 years) and a mean body mass index (and standard deviation) of 26.66 ± 4.79 kg/m underwent corrective surgery for cam deformity in association with FAI. Each patient underwent a computed tomography (CT) scan to assess acetabular bone mineral density (BMD), high-resolution T1ρ magnetic resonance imaging (MRI) of the hips to assess proteoglycan content, and squatting motion analysis as well as completed self-administered functional questionnaires (Hip disability and Osteoarthritis Outcome Score [HOOS]) both preoperatively and 2 years postoperatively. RESULTS: At a mean follow-up of 24.5 months, improvements in functional scores and squat performance were seen. Regarding the zone of impingement in the anterosuperior quadrant of the acetabular rim, the mean change in BMD at the time of follow-up was -31.8 mg/cc (95% confidence interval [CI], -11 to -53 mg/cc) (p = 0.008), representing a 5% decrease in BMD. The anterosuperior quadrant also demonstrated a significant decrease in T1ρ values, reflecting a stabilization of the cartilage degeneration. Significant correlations were noted between changes in clinical functional scores and changes in T1ρ values (r = -0.86; p = 0.003) as well as between the BMD and maximum vertical force (r = 0.878; p = 0.021). CONCLUSIONS: Surgical correction of a cam deformity in patients with symptomatic FAI not only improved clinical function but was also associated with decreases in T1ρ values and BMD. These findings are the first, to our knowledge, to show that alteration of the hip biomechanics through surgical intervention improves the overall health of the hip joint. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Femoracetabular Impingement/physiopathology , Femoracetabular Impingement/surgery , Hip Joint , Osteoarthritis, Hip/physiopathology , Acetabulum/diagnostic imaging , Acetabulum/pathology , Adult , Bone Density , Femur Head/abnormalities , Hip Joint/abnormalities , Hip Joint/physiopathology , Hip Joint/surgery , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Range of Motion, Articular , Young Adult
16.
J Biomech ; 55: 78-84, 2017 04 11.
Article in English | MEDLINE | ID: mdl-28259463

ABSTRACT

Femoro-acetabular impingement (FAI) is associated with significant acetabular cartilage damage and degenerative arthritis. To understand the contact stress and thus biomechanical mechanisms that may contribute to degeneration, the material behaviour of the cartilage layer is required. The objective of this study is to determine the fibril-reinforced poroelastic properties and composition of cartilage from cam deformities and to compare to those of normal cartilage. Patients undergoing surgical treatment of a symptomatic cam FAI deformity were recruited from the clinical practice of one of the authors. Osteochondral specimens were retrieved from the deformity during surgery using a trephine. Control specimens were retrieved from the anterior femoral head bearing surface during autopsy procedures. Indentation stress-relaxation tests were performed to determine the modulus (ES), Poisson's ratio (ν) and permeability (k0) of the poroelastic component, and the strain-independent (E0) and -dependent (Eε) moduli of the fibril-reinforcement using finite element analysis and optimization. Safranin-O staining was used to quantify proteoglycan content. ES and ν were 71% and 37% lower, respectively, in Cam specimens compared to controls, and k0 was approximately triple that of Control specimens (p<0.05). No significant differences were seen in the fibrillar components, E0 and Eε. Proteoglycan content was substantially depleted in Cam specimens, and was correlated with ES, ν and k0. This study showed that cartilage from the cam deformity exhibits severe degeneration in terms of the mechanical behaviour and composition changes, and is consistent with osteoarthritis. This further supports the hypothesis that FAI is a cause of hip osteoarthritis.


Subject(s)
Cartilage, Articular/pathology , Elasticity , Femoracetabular Impingement/pathology , Acetabulum/pathology , Biomechanical Phenomena , Cartilage, Articular/metabolism , Femoracetabular Impingement/metabolism , Femoracetabular Impingement/surgery , Femur Head/pathology , Finite Element Analysis , Humans , Proteoglycans/metabolism
17.
Comput Methods Biomech Biomed Engin ; 18(12): 1349-57, 2015.
Article in English | MEDLINE | ID: mdl-24697332

ABSTRACT

Hip resurfacing arthroplasty is an alternative to traditional hip replacement that can conserve proximal bone stock and has gained popularity but bone resorption may limit implant survival and remains a clinical concern. The goal of this study was to analyze bone remodelling patterns around an uncemented resurfacing implant and the influence of ingrowth regions on resorption. A computed tomography-derived finite element model of a proximal femur with a virtually implanted resurfacing component was simulated under peak walking loads. Bone ingrowth was simulated by six interface conditions: fully bonded; fully friction; bonded cap with friction stem; a small bonded region at the stem-cup intersection with the remaining surface friction; fully frictional, except for a bonded band along the distal end of the cap and superior half of the cap bonded with the rest frictional. Interface condition had a large influence on remodelling patterns. Bone resorption was minimized when no ingrowth occurred at the bone-implant interface. Bonding only the superior half of the cap increased bone resorption slightly but allowed for a large ingrowth region to improve secondary stability.


Subject(s)
Arthroplasty/methods , Bone Remodeling/physiology , Femur/surgery , Hip Prosthesis , Biomechanical Phenomena , Bone Resorption/physiopathology , Finite Element Analysis , Friction/physiology , Humans
18.
Hip Int ; 24(4): 347-54, 2014.
Article in English | MEDLINE | ID: mdl-24970323

ABSTRACT

INTRODUCTION: Accurate measurement of cup version on plain radiographs remains difficult due to the two-dimensional projection of an ellipse and difficulty obtaining reproducible radiographs. PURPOSE: Determine: 1) if the cup angle measured on the false profile view (FPV) could be used to determine radiographic cup version; 2) how patient positioning would affect cup angle measurement on the FPV; 3) if implant cup design affects cup angle measurement. MATERIALS AND METHODS: Three cup version positions were assessed in a sawbone: 13° (normal); 28° (excessive anteversion) and -2° (retroversion). Cup angle was measured on the FPV at five different degrees of pelvic rotation within each cup version group. Pelvic rotation was quantified using the ratio of the inter-femoral head distance measured on the FPV versus the anteroposterior radiographs (FP/AP ratio). Eighty patients (40 metal-on-polyethylene, 40 metal-on-metal) post-total hip were also assessed. Cup version was assessed with Einzel-Bild-Roentgen-Analysis software (EBRA). R2 was calculated to assess correlation between both measurement methods. RESULTS: For the sawbone model, an R2 of 0.95 was obtained. For patients, overall R2 was 0.56 with an FP/AP ratio of 0.3-0.49 having an R2 of 0.72. The EBRA anteversion versus cup angle scatterplot had an R2 of 0.72 (95%CI: +/-7.8°). Subgroup analysis revealed no differences between the metal-on-poly and metal-on-metal for cup angle measurements. The intra-class coefficient for intra- and inter-observer reliability for all cases (individual and combined FP/AP groups) was 0.98 to 0.99. CONCLUSION: The FPV cup angle measurement value provides an accurate measurement of radiographic cup anteversion with well-defined patient position parameters.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Joint/surgery , Hip Prosthesis , Tomography, X-Ray Computed/methods , Female , Hip Joint/diagnostic imaging , Humans , Male , Middle Aged , Prosthesis Design , ROC Curve , Reproducibility of Results
19.
J Biomech ; 47(10): 2348-53, 2014 Jul 18.
Article in English | MEDLINE | ID: mdl-24856886

ABSTRACT

The understanding of load support mechanisms in cartilage has evolved with computational models that better mimic the tissue ultrastructure. Fibril-reinforced poroelastic models can reproduce cartilage behaviour in a variety of test conditions and can be used to model tissue anisotropy as well as assess stress and pressure partitioning to the tissue constituents. The goal of this study was to examine the stress distribution in the fibrillar and non-fibrillar solid phase and pressure in the fluid phase of cartilage in axisymmetric models of a healthy and osteoarthritic hip joint. Material properties, based on values from the literature, were assigned to the fibrillar and poroelastic components of cartilage and cancellous and subchondral compact bone regions. A cyclic load representing walking was applied for 25 cycles. Contact stresses in the fibrillar and non-fibrillar solid phase supported less than 1% of the contact force and increased only minimally with load cycles. Simulated proteoglycan depletion increased stresses in the radial and tangential collagen fibrils, whereas fibrillation of the tangential fibrils resulted in increased compressive stress in the non-fibrillar component and tensile stress in the radial fibrils. However neither had an effect on fluid pressure. Subchondral sclerosis was found to have the largest effect, resulting in increased fluid pressure, non-fibrillar compressive stress, tangential fibril stress and greater cartilage consolidation. Subchondral bone stiffening may play an important role in the degenerative cascade and may adversely affect tissue repair and regeneration treatments.


Subject(s)
Cartilage, Articular/physiology , Femur Head/physiology , Hip Joint/physiopathology , Osteoarthritis/physiopathology , Anisotropy , Cartilage/physiopathology , Collagen/chemistry , Elasticity , Extracellular Matrix , Finite Element Analysis , Humans , Models, Anatomic , Porosity , Pressure , Proteoglycans/chemistry , Stress, Mechanical , Tomography, X-Ray Computed
20.
J Biomech ; 46(13): 2115-21, 2013 Sep 03.
Article in English | MEDLINE | ID: mdl-23906770

ABSTRACT

Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of boundary conditions, dynamic loading and hydraulic strengthening due to intra-medullary pressure on the predicted fracture strength. We developed a QCT-derived FE model of a proximal femur that included node-specific modulus assigned based on the local bone density. The effect of three commonly used boundary conditions published in literature were investigated by comparing the resulting strain field due to an applied fracture load. The models were also augmented with viscoelastic material properties and subject to a realistic impact load profile to determine the effect of dynamic loads on the strain field. Finally, the effect of hydraulic strengthening was investigated by including node specific permeability and performing a coupled pore diffusion and stress analysis of the FE model. Results showed that all boundary conditions yield the same strain field patterns, but peak strains were 22% lower and fracture load was 18% higher when loaded at the greater trochanter than when loaded at the femoral head. Comparison of the dynamic models showed that material viscoelasticity was important, but inertial effects (vibration and shock) were not. Finally, pore pressure changes did not cause significant hydraulic strengthening of bone under fall impact loading.


Subject(s)
Femoral Fractures/physiopathology , Femur/physiology , Models, Biological , Computer Simulation , Elasticity , Finite Element Analysis , Humans , Stress, Mechanical , Tomography, X-Ray Computed , Viscosity
SELECTION OF CITATIONS
SEARCH DETAIL
...