Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Surg Cases Innov Tech ; 7(3): 474-477, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34278086

ABSTRACT

Infection of peripheral arterial vascular grafts and stent-grafts represents a complex surgical scenario, with a number of proposed management strategies. Surgical removal of infected material with adjunctive arterial reconstruction is often required. However, surgical removal is often difficult and complex. This case study demonstrates an infected Viabahn stent-graft between the external iliac artery and the superficial femoral artery, with arterial autolysis of the common femoral artery and proximal superficial femoral artery, in which a hybrid technique combining remote endarterectomy and surgical debridement was used to remove the infected stent-graft.

2.
Eur Heart J Case Rep ; 2(4): yty147, 2018 Dec.
Article in English | MEDLINE | ID: mdl-31020222

ABSTRACT

BACKGROUND: We report the successful endovascular treatment of a coronary graft pseudoaneurysm using a technique often seen in intracranial aneurysm coiling. CASE SUMMARY: We present an unusual case of a patient who presents with haemopericardium and haemodynamic instability after saphenous vein bypass grafting. A pseudoaneurysm rapidly expanded from 5 cm to 7 cm over the follow-up period producing compressive mass effect on the lateral right ventricle with transient haemodynamic instability. The patient's declining clinical condition did not warrant a redo thoracotomy and sternotomy, so an endovascular approach was deemed to be the best treatment option. DISCUSSION: The use of endovascular embolization techniques is indeed a technically viable alternative with positive outcomes without the need for thoracotomy and sternotomy.

3.
J Neurointerv Surg ; 5 Suppl 3: iii72-iii75, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23612893

ABSTRACT

BACKGROUND: Complete packing of intracranial aneurysms has demonstrated a significant decrease in aneurysm recurrence rates with increased volumetric filling. The HydroCoil Embolization System (HES) was developed to increase volumetric filling within the aneurysm sac to maintain long term occlusion. To further enhance ease of HES deployment, a new next generation embolic coil, the HydroFill coil, was developed. OBJECTIVE: To report the first clinical experience with the HydroFill coil, focusing on safety and effectiveness, with immediate and long term follow-up on cases performed at a single institution by a single operator. METHODS: Retrospective angiographic and clinical analysis was performed on a non-randomized single arm registry of the first consecutive 11 patients with 14 intracranial saccular aneurysms treated during a 9 month period. RESULTS: The immediate angiographic occlusion rate according to the Raymond scale was 100%. Overall packing density of all coils used was 13-135% (mean 64%). The immediate complication rate was 9% (1/11 patients), secondary to a parent vessel occlusion which resolved after intravenous administration of eptifibatide (Integrilin) without neurological sequelae. The angiographic/MR angiography follow-up period for this series was 13-30 months, with an overall complete occlusion rate of 86% (12/14 aneurysms). 2/14 aneurysms (14%) converted from complete occlusion to filling of small neck remnants. Of the two, one (7%) was a cavernous aneurysm that was retreated. CONCLUSIONS: Although this initial case series is small, this study demonstrates safe deployment of the HydroFill coil in ruptured and unruptured aneurysms without major complications, and with a high rate of occlusion on long term follow-up.


Subject(s)
Embolization, Therapeutic/instrumentation , Intracranial Aneurysm/therapy , Adult , Aged , Aneurysm, Ruptured/surgery , Cerebral Angiography , Coated Materials, Biocompatible , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Female , Follow-Up Studies , Humans , Magnetic Resonance Angiography , Male , Middle Aged , Patient Safety , Reoperation , Retrospective Studies , Subarachnoid Hemorrhage/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...