Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 32(4): 6575-6586, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38439357

ABSTRACT

We introduce a portable dual-comb spectrometer operating in the visible spectral region for atmospheric monitoring of NO2, a pollution gas of major importance. Dual-comb spectroscopy, combining key advantages of fast, broadband and accurate measurements, has been established in the infrared as a method for the investigation of atmospheric gases with kilometer-scale absorption path lengths. With the presented dual-comb spectrometer centered at 517 nm, we make use of the strong absorption cross section of NO2 in this spectral region. In combination with a multi-pass approach through the atmosphere, we achieve an interaction path length of almost a kilometer while achieving both advanced spatial resolution (90 m) and a detection sensitivity of 5 ppb. The demonstrated temporal resolution of one minute outperforms the standard chemiluminescence-based NO2 detector that is commercially available and used in this experiment, by a factor of three.

2.
Front Physiol ; 13: 874472, 2022.
Article in English | MEDLINE | ID: mdl-35784872

ABSTRACT

The reconstitution of secondary active transporters into liposomes shed light on their molecular transport mechanism. The latter are either symporters, antiporters or exchangers, which use the energy contained in the electrochemical gradient of ions to fuel concentrative uptake of their cognate substrate. In liposomal preparations, these gradients can be set by the experimenter. However, due to passive diffusion of the ions and solutes through the membrane, the gradients are not stable and little is known on the time course by which they dissipate and how the presence of a transporter affects this process. Gradient dissipation can also generate a transmembrane potential (VM). Because it is the effective ion gradient, which together with VM fuels concentrative uptake, knowledge on how these parameters change within the time frame of the conducted experiment is key to understanding experimental outcomes. Here, we addressed this problem by resorting to a modelling approach. To this end, we mathematically modeled the liposome in the assumed presence and absence of the sodium glucose transporter 1 (SGLT1). We show that 1) the model can prevent us from reaching erroneous conclusions on the driving forces of substrate uptake and we 2) demonstrate utility of the model in the assignment of the states of SGLT1, which harbor a water channel.

3.
Nanoscale Adv ; 4(1): 58-76, 2021 Dec 21.
Article in English | MEDLINE | ID: mdl-35028506

ABSTRACT

The endeavors to understand the determinants of water permeation through membrane channels, the effect of the lipid or polymer membrane on channel function, the development of specific water flow inhibitors, the design of artificial water channels and aquaporins for the use in industrial water filtration applications all rely on accurate ways to quantify water permeabilities (P f). A commonly used method is to reconstitute membrane channels into large unilamellar vesicles (LUVs) and to subject these vesicles to an osmotic gradient in a stopped-flow device. Fast recordings of either scattered light intensity or fluorescence self-quenching signals are taken as a readout for vesicle volume change, which in turn can be recalculated to accurate P f values. By means of computational and experimental data, we discuss the pros and cons of using scattering versus self-quenching experiments or subjecting vesicles to hypo- or hyperosmotic conditions. In addition, we explicate for the first time the influence of the LUVs size distribution, channel distribution between vesicles and remaining detergent after protein reconstitution on P f values. We point out that results such as the single channel water permeability (p f) depend on the membrane matrix or on the direction of the applied osmotic gradient may be direct results of the measurement and analysis procedure.

SELECTION OF CITATIONS
SEARCH DETAIL
...