Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 14(1): 11075, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38744882

ABSTRACT

Magnetoelastic micro-electromechanical systems (MEMS) are integral elements of sensors, actuators, and other devices utilizing magnetostriction for their functionality. Their sensitivity typically scales with the saturation magnetostriction and inversely with magnetic anisotropy. However, large saturation magnetostriction and small magnetic anisotropy make the magnetoelastic layer highly susceptible to minuscule anisotropic stress. It is inevitably introduced during the release of the mechanical structure during fabrication and severely impairs the device's reproducibility, performance, and yield. To avoid the transfer of residual stress to the magnetic layer, we use a shadow mask deposition technology. It is combined with a free-free magnetoelectric microresonator design to minimize the influence of magnetic inhomogeneity on device performance. Magnetoelectric resonators are experimentally and theoretically analyzed regarding local stress anisotropy, magnetic anisotropy, and the ΔE-effect sensitivity in several resonance modes. The results demonstrate an exceptionally small device-to-device variation of the resonance frequency < 0.2% with large sensitivities comparable with macroscopic ΔE-effect magnetic field sensors. This development marks a promising step towards highly reproducible magnetoelastic devices and the feasibility of large-scale, integrated arrays.

2.
Sensors (Basel) ; 23(11)2023 May 23.
Article in English | MEDLINE | ID: mdl-37299738

ABSTRACT

Magnetoelectric thin-film cantilevers consisting of strain-coupled magnetostrictive and piezoelectric layers are promising candidates for magnetic field measurements in biomedical applications. In this study, we investigate magnetoelectric cantilevers that are electrically excited and operated in a special mechanical mode with resonance frequencies above 500 kHz. In this particular mode, the cantilever bends in the short axis, forming a distinctive U-shape and exhibiting high-quality factors and a promising limit of detection of 70pT/Hz1/2 at 10 Hz. Despite this U mode, the sensors show a superimposed mechanical oscillation along the long axis. The induced local mechanical strain in the magnetostrictive layer results in magnetic domain activity. Due to this, the mechanical oscillation may cause additional magnetic noise, deteriorating the limit of detection of such sensors. We compare finite element method simulations with measurements of magnetoelectric cantilevers in order to understand the presence of oscillations. From this, we identify strategies for eliminating the external effects that affect sensor operation. Furthermore, we investigate the influence of different design parameters, in particular the cantilever length, material parameters and the type of clamping, on the amplitude of the undesired superimposed oscillations. We propose design guidelines to minimize the unwanted oscillations.


Subject(s)
Electricity , Magnetic Fields , Physical Therapy Modalities , Records , Vibration
3.
Sci Rep ; 13(1): 8446, 2023 May 25.
Article in English | MEDLINE | ID: mdl-37231050

ABSTRACT

Magnetoelastic composites which use surface acoustic waves show great potential as sensors of low frequency and very low amplitude magnetic fields. While these sensors already provide adequate frequency bandwidth for most applications, their detectability has found its limitation in the low frequency noise generated by the magnetoelastic film. Amongst other contributions, this noise is closely connected to domain wall activity evoked by the strain from the acoustic waves propagating through the film. A successful method to reduce the presence of domain walls is to couple the ferromagnetic material with an antiferromagnetic material across their interface and therefore induce an exchange bias. In this work we demonstrate the application of a top pinning exchange bias stack consisting of ferromagnetic layers of (Fe90Co10)78Si12B10 and Ni81Fe19 coupled to an antiferromagnetic Mn80Ir20 layer. Stray field closure and hence prevention of magnetic edge domain formation is achieved by an antiparallel biasing of two consecutive exchange bias stacks. The set antiparallel alignment of magnetization provides single domain states over the complete films. This results in a reduction of magnetic phase noise and therefore provides limits of detection as low as 28 pT/Hz1/2 at 10 Hz and 10 pT/Hz1/2 at 100 Hz.

SELECTION OF CITATIONS
SEARCH DETAIL
...