Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
2.
Bioelectromagnetics ; 33(2): 124-33, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21842517

ABSTRACT

A head exposure setup for efficient and precisely defined exposure of human subjects equipped with a near-infrared imaging (NIRI) sensor is presented. In a partially shielded anechoic chamber the subjects were exposed to Universal Mobile Telecommunications System (UMTS)-like electromagnetic fields (EMF) by using a patch antenna at a distance of 4 cm from the head. The non-contact design of the exposure setup enabled NIRI sensors to easily attach to the head. Moreover, different regions of the head were chosen for localised exposure and simultaneous NIRI investigation. The control software enabled the simple adaptation of the test parameters during exploratory testing as well as the performance of controlled, randomised, crossover and double-blind provocation studies. Four different signals with a carrier frequency of 1900 MHz were chosen for the exposure: a simple continuous wave signal and three different UMTS signals. Furthermore, three exposure doses were available: sham, low (spatial peak specific absorption rate (SAR) = 0.18 W/kg averaged over 10 g) and high (spatial peak SAR = 1.8 W/kg averaged over 10 g). The SAR assessment was performed by measurement and simulation. Direct comparison of measurement and numerical results showed good agreement in terms of spatial peak SAR and SAR distribution. The variability analysis of the spatial peak SAR over 10 g was assessed by numerical simulations. Maximal deviations of -22% and +32% from the nominal situation were observed. Compared to other exposure setups, the present setup allows for low exposure uncertainty, combined with high SAR efficiency, easy access for the NIRI sensor and minimal impairment of test subjects.


Subject(s)
Blood Flow Velocity/physiology , Cell Phone/instrumentation , Cerebrovascular Circulation/physiology , Electric Stimulation/instrumentation , Radiometry/instrumentation , Spectroscopy, Near-Infrared/instrumentation , Blood Flow Velocity/radiation effects , Cerebrovascular Circulation/radiation effects , Computer Simulation , Computer-Aided Design , Electromagnetic Fields , Equipment Design , Equipment Failure Analysis , Head/physiology , Head/radiation effects , Models, Biological , Radiation Dosage
3.
Bioelectromagnetics ; 33(1): 40-54, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21695708

ABSTRACT

The aim of the present study was to assess the potential effects of intermittent Universal Mobile Telecommunications System electromagnetic fields (UMTS-EMF) on blood circulation in the human head (auditory region) using near-infrared spectroscopy (NIRS) on two different timescales: short-term (effects occurring within 80 s) and medium-term (effects occurring within 80 s to 30 min). For the first time, we measured potential immediate effects of UMTS-EMF in real-time without any interference during exposure. Three different exposures (sham, 0.18 W/kg, and 1.8 W/kg) were applied in a controlled, randomized, crossover, and double-blind paradigm on 16 healthy volunteers. In addition to oxy-, deoxy-, and total haemoglobin concentrations ([O(2) Hb], [HHb], and [tHb], respectively), the heart rate (HR), subjective well-being, tiredness, and counting speed were recorded. During exposure to 0.18 W/kg, we found a significant short-term increase in Δ[O(2) Hb] and Δ[tHb], which is small (≈17%) compared to a functional brain activation. A significant decrease in the medium-term response of Δ[HHb] at 0.18 and 1.8 W/kg exposures was detected, which is in the range of physiological fluctuations. The medium-term ΔHR was significantly higher (+1.84 bpm) at 1.8 W/kg than for sham exposure. The other parameters showed no significant effects. Our results suggest that intermittent exposure to UMTS-EMF has small short- and medium-term effects on cerebral blood circulation and HR.


Subject(s)
Blood Circulation/radiation effects , Cell Phone , Ear/blood supply , Electromagnetic Fields/adverse effects , Infrared Rays/adverse effects , Adult , Dose-Response Relationship, Radiation , Ear/radiation effects , Female , Hemoglobins/metabolism , Humans , Male , Motor Cortex/physiology , Motor Cortex/radiation effects , Oxyhemoglobins/metabolism , Time Factors
4.
Lasers Med Sci ; 26(2): 205-12, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20814712

ABSTRACT

Preterm labor is a common obstetric complication. Clinical evaluation of cervical ripening to predict preterm labor is very inaccurate. We used frequency-domain near-infrared spectroscopy (FD-NIRS) to non-invasively investigate the changes of the optical properties (i.e., absorption and scattering of light) in the uterine cervix during regular pregnancies. Optical properties of uterine cervices were measured in 13 patients at various time points of regular pregnancies. For each gestational trimester, mean values with 95% confidence intervals were calculated for oxy-, deoxy-, and total hemoglobin concentration (O(2)Hb, HHb, tHb), tissue oxygen saturation and water content and statistically significant differences between the trimesters were determined. The wavelength-dependent scattering (scatter power) was calculated by an exponential fit. O(2)Hb, and tHb and the scatter power showed an increase as a function of the gestational age. Differences between the second and the third trimester were statistically significant. HHb and the water content showed no significant change over time. Our results show that FD-NIRS is a promising diagnostic tool for providing information about cervical content of hemoglobin, water, and extracellular matrix proteins. We propose this technology to assess the cervical ripening and eventually to predict preterm labor.


Subject(s)
Cervical Ripening/metabolism , Cervix Uteri/chemistry , Obstetric Labor, Premature/diagnosis , Spectroscopy, Near-Infrared , Adult , Cervix Uteri/physiology , Female , Hemoglobins/analysis , Humans , Oxygen/analysis , Pregnancy , Water/analysis , Young Adult
5.
Rev Sci Instrum ; 80(2): 024301, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19256664

ABSTRACT

In this paper we describe the modification and assessment of a standard multidistance frequency-domain near infrared spectroscopy (NIRS) instrument to perform multifrequency frequency-domain NIRS measurements. The first aim of these modifications was to develop an instrument that enables measurement of small volumes of tissue such as the cervix, which is too small to be measured using a multidistance approach. The second aim was to enhance the spectral resolution to be able to determine the absolute concentrations of oxy-, deoxy- and total hemoglobin, water, and lipids. The third aim was to determine the accuracy and error of measurement of this novel instrument in both in vitro and in vivo environments. The modifications include two frequency synthesizers with variable, freely adjustable frequency, broadband high-frequency amplifiers, the development of a novel avalanche photodiode (APD) detector and demodulation circuit, additional laser diodes with additional wavelengths, and a respective graphic user interface to analyze the measurements. To test the instrument and algorithm, phantoms with optical properties similar to those of biological tissue were measured and analyzed. The results show that the absorption coefficient can be determined with an error of <10%. The error of the scattering coefficient was <31%. Since the accuracy of the chromophore concentrations depends on the absorption coefficient and not on the scattering coefficient, the <10% error is the clinically relevant parameter. In addition, the new APD had similar accuracy as the standard photomultiplier tubes. To determine the accuracy of chromophore concentration measurements we employed liquid Intralipid(R) phantoms that contained 99% water, 1% lipid, and an increasing concentration of hemoglobin in steps of 0.010 mM. Water concentration was measured with an accuracy of 6.5% and hemoglobin concentration with an error of 0.0024 mM independent of the concentration. The measured lipid concentration was negative, which shows that the current setup is not suitable for measuring lipids. Measurements on the forearm confirmed reasonable values for water and hemoglobin concentrations, but again not for lipids. As an example of a future application, chromophore concentrations in the cervix were measured and comparable values to the forearm were found. In conclusion the modified instrument enables measurement of water concentration in addition to oxy- and deoxyhemoglobin concentrations with a single source-detector distance in small tissue samples. Future work will focus on resolving the lipid component.


Subject(s)
Hemoglobins/analysis , Lipids/analysis , Oximetry/instrumentation , Oxygen/analysis , Spectroscopy, Near-Infrared/instrumentation , Tissue Array Analysis/instrumentation , Water/analysis , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Humans , Male , Reproducibility of Results , Sensitivity and Specificity , Spectroscopy, Near-Infrared/methods , Tissue Array Analysis/methods
6.
Opt Express ; 16(17): 12973-86, 2008 Aug 18.
Article in English | MEDLINE | ID: mdl-18711536

ABSTRACT

Biomedical sensors, integrated into textiles would enable monitoring of many vitally important physiological parameters during our daily life. In this paper we demonstrate the design and performance of a textile based pulse oximeter, operating on the forefinger tip in transmission mode. The sensors consisted of plastic optical fibers integrated into common fabrics. To emit light to the human tissue and to collect transmitted light the fibers were either integrated into a textile substrate by embroidery (producing microbends with a nominal diameter of 0.5 to 2 mm) or the fibers inside woven patterns have been altered mechanically after fabric production. In our experiments we used a two-wavelength approach (690 and 830 nm) for pulse wave acquisition and arterial oxygen saturation calculation. We have fabricated different specimens to study signal yield and quality, and a cotton glove, equipped with textile based light emitter and detector, has been used to examine movement artifacts. Our results show that textile-based oximetry is feasible with sufficient data quality and its potential as a wearable health monitoring device is promising.


Subject(s)
Biosensing Techniques/instrumentation , Lighting/instrumentation , Oximetry/instrumentation , Photometry/instrumentation , Textiles , Equipment Design , Equipment Failure Analysis , Semiconductors
SELECTION OF CITATIONS
SEARCH DETAIL
...