Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
J Vet Pharmacol Ther ; 33(2): 118-31, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20444036

ABSTRACT

The objectives of this study were to establish dose-response and blood concentration-response relationships for robenacoxib, a novel nonsteroidal anti-inflammatory drug with selectivity for inhibition of the cyclooxygenase (COX)-2 isoenzyme, in a canine model of synovitis. Acute synovitis of the stifle joint was induced by intra-articular injection of sodium urate crystals. Robenacoxib (0.25, 0.5, 1.0, 2.0 and 4.0 mg/kg), placebo and meloxicam (0.2 mg/kg) were administered subcutaneously (s.c.) 3 h after the urate crystals. Pharmacodynamic endpoints included data from forceplate analyses, clinical orthopaedic examinations and time course of inhibition of COX-1 and COX-2 in ex vivo whole blood assays. Blood was collected for pharmacokinetics. Robenacoxib produced dose-related improvement in weight-bearing, pain and swelling as assessed objectively by forceplate analysis (estimated ED(50) was 1.23 mg/kg for z peak force) and subjectively by clinical orthopaedic assessments. The analgesic and anti-inflammatory effects of robenacoxib were significantly superior to placebo (0.25-4 mg/kg robenacoxib) and were non-inferior to meloxicam (0.5-4 mg/kg robenacoxib). All dosages of robenacoxib produced significant dose-related inhibition of COX-2 (estimated ED(50) was 0.52 mg/kg) but no inhibition of COX-1. At a dosage of 1-2 mg/kg administered s.c., robenacoxib should be at least as effective as 0.2 mg/kg of meloxicam in suppressing acute joint pain and inflammation in dogs.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal/therapeutic use , Diphenylamine/analogs & derivatives , Dog Diseases/chemically induced , Phenylacetates/therapeutic use , Synovitis/veterinary , Animals , Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Anti-Inflammatory Agents, Non-Steroidal/pharmacokinetics , Area Under Curve , Diphenylamine/administration & dosage , Diphenylamine/pharmacokinetics , Diphenylamine/therapeutic use , Dog Diseases/drug therapy , Dogs , Dose-Response Relationship, Drug , Female , Half-Life , Male , Meloxicam , Phenylacetates/administration & dosage , Phenylacetates/pharmacokinetics , Synovitis/chemically induced , Thiazines/therapeutic use , Thiazoles/therapeutic use , Uric Acid/toxicity
2.
Schweiz Arch Tierheilkd ; 138(11): 537-45, 1996.
Article in German | MEDLINE | ID: mdl-9026911

ABSTRACT

This article describes in short sections the use and interpretation of indirect blood pressure measurements, central venous pressure, body temperature, pulse oximetry, end tidal CO2 measurements, pulse and heart rate, urine production and emergency laboratory values. Most of these parameters are directly or indirectly linked to the perfusion of the patient. Optimizing these values are one of the most important goals in emergency and critical care medicine.


Subject(s)
Animals, Domestic , Critical Care , Emergencies/veterinary , Monitoring, Physiologic/veterinary , Animals , Blood Pressure Determination/veterinary , Body Temperature , Capnography/veterinary , Cats , Central Venous Pressure , Dogs , Heart Rate , Oximetry/veterinary , Urination
3.
Resuscitation ; 29(2): 153-6, 1995 Apr.
Article in English | MEDLINE | ID: mdl-7659868

ABSTRACT

STUDY OBJECTIVE: To determine the effectiveness of an esophageal doppler device to non-invasively detect experimental pseudo-electromechanical dissociation (pseudo-EMD). DESIGN: Prospective, controlled, laboratory investigation using an asphyxial canine cardiac arrest model and a newly-developed esophageal flat-flow probe doppler unit. INTERVENTIONS: Mongrel dogs (20) were instrumented for hemodynamic monitoring. The esophageal doppler probe was placed in the distal esophagus of each animal. Electromechanical dissociation (EMD) was induced by clamping the endotracheal tube. MEASUREMENTS AND MAIN RESULTS: A period of pseudo-EMD was defined as the time where cardiac contractility was present, measured by a micromanometer tipped thoracic aortic catheter, without concurrent femoral pulses by palpation. The pseudo-EMD period could be produced consistently in all 20 animals. The characteristic doppler flow sounds were easily heard using the esophageal device in all animals. The time from endotracheal tube clamping until loss of femoral pulses was 622 +/- 96 s; until loss of radial artery doppler signals was 616 +/- 92 s; until loss of esophageal doppler signals was 728 +/- 88 s; and until loss of aortic fluctuations by thoracic aortic catheter was 728 +/- 82 s. The times to loss of esophageal doppler sounds and loss of aortic fluctuations were not significantly different. However, they were significantly longer than the time to loss of femoral pulses (P < 0.02). CONCLUSIONS: The canine asphyxial EMD model can be used for short experimental studies of pseudo-EMD. Pseudo-EMD can be consistently and non-invasively detected with this esophageal doppler device. The device is as reliable as a micromanometer tipped aortic arch catheter in detecting pseudo-EMD. The doppler device could potentially be useful in improving recognition of near cardiac arrest in pre-hospital and emergency department settings. Further research on the utility of this device in other models of low-flow states should be performed.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Heart Arrest/physiopathology , Ultrasonography, Doppler/methods , Animals , Blood Flow Velocity/physiology , Disease Models, Animal , Dogs , Equipment Design , Esophagus , Heart Arrest/diagnostic imaging , Heart Arrest/therapy , Hemodynamics/physiology , Prospective Studies , Ultrasonography, Doppler/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...