Int J Clin Pract ; 57(4): 349-50, 2003 May.
Article in English | MEDLINE | ID: mdl-12800472

ABSTRACT

Evolving pacemaker and device technology now allows the onset pattern of arrhythmias to be identified. It is recognised that some cardiac arrhythmias have a circadian pattern of onset and that ventricular arrhythmias can occur in clusters of electrical storms. The long-term follow-up of patients with an atrial defibrillator suggests that in some patients persistent atrial fibrillation recurrences are not random, but can occur in clusters of 'atrial fibrillation storms'. A case report is used to demonstrate this newly recognised phenomenon.


Subject(s)
Atrial Fibrillation/physiopathology , Circadian Rhythm , Defibrillators, Implantable , Amiodarone/therapeutic use , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/therapy , Humans , Hypnotics and Sedatives/therapeutic use , Male , Midazolam/therapeutic use , Middle Aged , Recurrence
2.
Heart ; 87(5): 433-7, 2002 May.
Article in English | MEDLINE | ID: mdl-11997413

ABSTRACT

OBJECTIVE: To assess the true efficacy of antitachycardia pacing on spontaneous persistent atrial fibrillation in patients with an implanted atrial defibrillator, by comparing the effects of nominal pacing treatment with subthreshold pacing treatment. DESIGN: The effects of antitachycardia pacing and burst 50 Hz atrial pacing on spontaneous atrial arrhythmias were evaluated six months after implantation of a Medtronic Jewel AF((R)) atrial defibrillator. SETTING: Cardiology department in a district general hospital. PATIENTS: 15 patients with persistent atrial fibrillation. INTERVENTIONS: Patients were randomised to either "nominal" output pacing treatment or surface ECG and endocardial electrogram proven subthreshold "sham" pacing treatment for three months, and then crossed over to the alternative treatment for a further three months. RESULTS: During the nominal output phase, 31 episodes of atrial fibrillation were treated with 53 bursts of 50 Hz pacing, 98 sequences of ramp atrial pacing, and 61 sequences of burst atrial pacing. Atrial fibrillation was not pace terminated during any episode. Thirty one episodes of atrial tachycardia were treated with 19 bursts of 50 Hz atrial pacing, 103 sequences of ramp atrial pacing, and 38 sequences of burst atrial pacing. Termination of atrial tachycardia was observed in 17 episodes. During the "sham" pacing period, no episodes were terminated by any pacing treatment. CONCLUSION: Atrial antitachycardia pacing treatments are ineffective at terminating persistent atrial fibrillation but may be useful in terminating episodes of atrial tachycardia or flutter, thus reducing the burden of arrhythmia.


Subject(s)
Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/methods , Defibrillators, Implantable , Adult , Aged , Aged, 80 and over , Death, Sudden, Cardiac/prevention & control , Female , Humans , Male , Middle Aged , Risk Factors , Survival Analysis , Tachycardia/therapy , Treatment Outcome
3.
Europace ; 4(1): 41-4, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11858153

ABSTRACT

AIMS: To compare the atrial defibrillation threshold (DFT) for two electrode configurations in patients with drug refractory persistent atrial fibrillation (AF). METHODS AND RESULTS: 11 patients, 73% male, mean age 60.9 (range 38 to 83), underwent implantation of a Medtronic Jewel AF dual chamber defibrillator (model 7250). A step-up atrial DFT was performed in a randomized sequence for two electrode configurations: (1) Right atrial to distal coronary sinus electrode (RA > CS) and (2) defibrillator can to right ventricular and right atrial electrodes (CAN > RV + RA). The RA > CS configuration restored SR in 10 patients (91%). The CAN > RA + RV configuration restored SR in four patients (36%). The mean atrial DFT was significantly lower for the RA > CS than CAN > RA + RV configuration (10 +/- 7 Joules vs 25 +/- 6 Joules), P < 0.01. At 3 months post implantation, AF was reinduced and the protocol was repeated for the optimal electrode configuration. There was no significant difference in the atrial DFT compared with that at implant. CONCLUSION: The right atrium to coronary sinus electrode configuration significantly reduces the atrial DFT. The atrial DFT also remains stable at 3 months post-implantation. Patients with persistent AF undergoing insertion of an atrial defibrillator should have a coronary sinus electrode implanted.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Defibrillators, Implantable , Differential Threshold/physiology , Equipment Design , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Humans , Male , Middle Aged