Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Nucl Med ; 49(6): 557-558, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38598452

ABSTRACT

ABSTRACT: We report the successful application of radioembolization (SIRT) in a 77-year-old man with end-stage renal disease on hemodialysis and repeated episodes of macroscopic hematuria due to a large renal cell carcinoma of the right kidney extending to liver segment VI. A compassionate SIRT therapy was performed with resin microspheres through the upper pole renal artery and the feeding segmental artery of liver segment VI. Hematuria was resolved after treatment, and 4 months later, a follow-up CT scan revealed tumor size reduction and complete tumor necrosis (Response Evaluation Criteria in Solid Tumors criteria). Ablative SIRT therapy could be a safe and efficient option in a large inoperable RCC.


Subject(s)
Carcinoma, Renal Cell , Embolization, Therapeutic , Hematuria , Kidney Neoplasms , Humans , Male , Aged , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/radiotherapy , Carcinoma, Renal Cell/complications , Carcinoma, Renal Cell/pathology , Hematuria/etiology , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/pathology , Kidney Neoplasms/radiotherapy , Kidney Neoplasms/complications , Necrosis , Liver Neoplasms/radiotherapy , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/complications , Neoplasm Invasiveness , Liver/diagnostic imaging , Liver/pathology , Tomography, X-Ray Computed
2.
Article in English | MEDLINE | ID: mdl-38083146

ABSTRACT

Coronary artery disease (CAD) is a chronic disease associated with high mortality and morbidity. Although treatment with drug-eluting stents is the most frequent interventional approach for coronary artery disease, drug-coated balloons (DCBs) constitute an innovative alternative, especially in the presence of certain anatomical conditions in the local coronary vasculature. DCBs allow the fast and homogenous transfer of drugs into the arterial wall, during the balloon inflation. Their use has been established for treating in-stent restenosis caused by stent implantation, while recent clinical trials have shown a satisfactory efficacy in de novo small-vessel disease. Several factors affect DCBs performance including the catheter design, the drug dose and formulation. Cleverballoon focuses on the design and development of an innovative DCB with everolimus. For the realization of the development of this new DCB, an integrated approach, including in- vivo, in-vitro studies and in-silico modelling towards the DCB optimization, is presented.Clinical Relevance-The proposed study introduces the integration of in- vivo, in-vitro and in silico approaches in the design and development process of a new DCB, following the principles of 3R's for the replacement, reduction, and refinement of animal and clinical studies.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Animals , Coronary Artery Disease/therapy , Everolimus/pharmacology , Treatment Outcome
3.
Sci Rep ; 12(1): 13909, 2022 08 17.
Article in English | MEDLINE | ID: mdl-35977960

ABSTRACT

Coronary angiography and percutaneous coronary intervention (PCI) procedural details in swine are similar to those performed to humans, since their heart and coronary anatomy closely resembles. However, only a few detailed descriptions of the procedure are available, containing notable differences. We present a feasible and reproducible protocol for percutaneous coronary interventions in porcine experimental models, utilizing ultrasound-guided femoral approach. Nine female pigs were studied to explore the feasibility of superficial femoral arterial (SFA) access for coronary angiography and provisional PCI, as well as the most suitable guiding coronary catheters and angiographic projections for the above interventions. Experiments were performed under general anesthesia, using ultrasound-guided puncture of the SFA to gain arterial access. The Amplatzer AR1® catheter, and the Right Coronary Bypass® catheter were used for the selective engagement of the right and the left coronary artery, respectively. Successful arterial access and subsequent cardiac catheterization were performed in all pigs. Only one animal required a second puncture for femoral artery access. None of the 9 animals presented any significant tachycardia or hypotensive episode. One animal developed an access site-related complication following the first catheterization procedure. During follow-up, 100% success of SFA catheterization was achieved using the same ultrasound-guided technique. The ultrasound-guided superficial femoral artery access for coronary angiography and provisional interventions in porcine models is a quick and safe alternative to the carotid artery approach. The RCB and AR1 catheters may be the best choice for the quick and easy selective coronary engagement of the right and left ostia, respectively.


Subject(s)
Femoral Artery , Percutaneous Coronary Intervention , Animals , Cardiac Catheterization/methods , Coronary Angiography/methods , Female , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Percutaneous Coronary Intervention/methods , Radial Artery , Swine , Treatment Outcome , Ultrasonography, Interventional
4.
J Vasc Interv Radiol ; 30(2): 212-216, 2019 02.
Article in English | MEDLINE | ID: mdl-30717952

ABSTRACT

PURPOSE: A retrospective longitudinal analysis was performed to evaluate the outcome of consecutive treatments with drug-coated balloons (DCBs) in dysfunctional arteriovenous (AV) dialysis access (fistulae and grafts). MATERIALS AND METHODS: From January 2015 to December 2017, 339 DCBs were used in 257 procedures in 165 patients with dysfunctional accesses. Of these, 38 patients had ≥ 2 procedures and were included in the analysis. A total of 112 procedures were performed with 133 devices (22 patients treated twice, 4 treated 3 times, 7 treated 4 times, 2 treated 5 times, and 3 treated 6 times). Mean balloon diameter was 8.13 mm (min-max range, 3-12 mm) and length was 63.16 mm (min-max range, 40-150 mm). Primary outcome measures were safety and effectiveness based on the noninferiority hypothesis that the second treatment would be as effective as the first regarding postintervention primary patency (PIPP). Secondary outcome measures included independent factors that may influence outcomes. RESULTS: Mean lesion follow-up was 617 d (range, 175-1,100 d). Median PIPP durations were 216.5 d for the first intervention and 280 d for the second (P = .37; hazard ratio, 1.271; 95% confidence interval, 0.75-2.16). There was a significant difference in PIPP in favor of the second intervention when patients with only 2 interventions (22 of 38; 57.9%) were included (first intervention, 269 d; second intervention, 520 d; P = .03; hazard ratio, 2.354; 95% confidence interval, 1.087-5.098). CONCLUSIONS: There was no significant difference in PIPP between the first and second DCB procedures. Results suggest consistency in PIPP with the use of DCBs regardless of aging AV access.


Subject(s)
Angioplasty, Balloon/instrumentation , Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Graft Occlusion, Vascular/therapy , Renal Dialysis , Vascular Access Devices , Vascular Patency , Adult , Aged , Aged, 80 and over , Angioplasty, Balloon/adverse effects , Cardiovascular Agents/adverse effects , Equipment Design , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/physiopathology , Humans , Longitudinal Studies , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...