1.
AJNR Am J Neuroradiol ; 44(8): 939-942, 2023 08.
Article in English | MEDLINE | ID: mdl-37474263

ABSTRACT

Nickel is used in many cerebral endovascular treatment devices. However, nickel hypersensitivity is the most common metal allergy, and the relative risk of treatment in these patients is unknown. This retrospective analysis identified patients with nickel or metal allergies who underwent cerebral endovascular treatment with nickel-containing devices. Seven patients with nickel and/or other metal allergies underwent treatment with 9 nickel-containing devices. None experienced periprocedural complications. No patient received treatment with corticosteroids or antihistamines. At a mean clinical follow-up for all patients of 22.8 months (range, 10.5-38.0 months), no patients had symptoms attributable to nickel allergic reactions. The mean radiographic follow-up for all patients at 18.4 months (range, 2.5-37.5 months) showed successful treatment of the targeted vascular pathologies, with no evidence of in-stent stenosis or other allergic or hypersensitivity sequelae. The treatment of cerebrovascular lesions with a nickel-containing device resulted in no adverse outcomes among these patients and was safe and effective.


Subject(s)
Cerebrovascular Disorders , Hypersensitivity , Humans , Nickel/adverse effects , Retrospective Studies , Hypersensitivity/etiology , Hypersensitivity/therapy , Hypersensitivity/diagnosis , Alloys/adverse effects , Cerebrovascular Disorders/complications
2.
AJNR Am J Neuroradiol ; 43(8): 1148-1151, 2022 08.
Article in English | MEDLINE | ID: mdl-35863784

ABSTRACT

BACKGROUND AND PURPOSE: Middle meningeal artery embolization after surgical evacuation of a chronic subdural hematomas is associated with fewer treatment failures than surgical evacuation. We compared emergency department visits within 30 days for patients with chronic subdural hematomas with and without adjunctive middle meningeal artery embolization. MATERIALS AND METHODS: All cases of chronic subdural hematoma treated from January 1, 2018, through December 31, 2020, were retrospectively reviewed. Treatment was classified as surgery only or surgery combined with middle meningeal artery embolization. The primary outcome was 30-day emergency department presentation and readmission. RESULTS: Of 137 patients who met the study criteria, 28 (20%) underwent surgery combined with middle meningeal artery embolization. Of these 28 patients, 15 (54%) underwent planned middle meningeal artery embolization and 13 (46%) underwent embolization after surgical failure. The mean chronic subdural hematoma size at presentation in the group with surgery only (n = 109, 20.5 [SD, 6.9] mm) was comparable with that in the combined group (n = 28, 18.7 [SD, 4.5] mm; P = .16). A significantly higher percentage of the surgery-only group presented to the emergency department within 30 days compared with the combined group (32 of 109 [29%] versus 2 of 28 [7%] patients; P = .02). No significant difference was found with respect to readmission (16 [15%] versus 1 [4%] patient; P = .11). Nine patients (8%) in the surgery-only group were readmitted for significant reaccumulation or residual subdural hematoma compared with only 1 patient (4%) in the combined group (P = .40). CONCLUSIONS: Surgical evacuation combined with middle meningeal artery embolization in patients with chronic subdural hematoma is associated with fewer 30-day emergency department visits compared with surgery alone.


Subject(s)
Embolization, Therapeutic , Hematoma, Subdural, Chronic , Humans , Hematoma, Subdural, Chronic/diagnostic imaging , Hematoma, Subdural, Chronic/surgery , Meningeal Arteries/diagnostic imaging , Meningeal Arteries/surgery , Retrospective Studies , Treatment Outcome , Embolization, Therapeutic/methods
3.
AJNR Am J Neuroradiol ; 42(5): 904-909, 2021 05.
Article in English | MEDLINE | ID: mdl-33707283

ABSTRACT

BACKGROUND AND PURPOSE: EmboTrap II is a novel stent retriever with a dual-layer design and distal mesh designed for acute ischemic stroke emergent large-vessel occlusions. We present the first postmarket prospective multicenter experience with the EmboTrap II stent retriever. MATERIALS AND METHODS: A prospective registry of patients treated with EmboTrap II at 7 centers following FDA approval was maintained with baseline patient characteristics, treatment details, and clinical/radiographic follow-up. RESULTS: Seventy patients were treated with EmboTrap II (mean age, 69.9 years; 48.6% women). Intravenous thrombolysis was given in 34.3%, and emergent large-vessel occlusions were located in the ICA (n = 18), M1 (n = 38), M2 or M3 (n = 13), and basilar artery (n = 1). The 5 × 33 mm device was used in 88% of cases. TICI ≥ 2b recanalization was achieved in 95.7% (82.3% in EmboTrap II-only cases), and first-pass efficacy was achieved in 35.7%. The NIHSS score improved from a preoperative average of 16.3 to 12.1 postprocedure and to 10.5 at discharge. An average of 2.5 [SD, 1.8] passes was recorded per treatment, including non-EmboTrap attempts. Definitive treatment was performed with an alternative device (aspiration or stent retriever) in 9 cases (12.9%). Some hemorrhagic conversion was noted in 22.9% of cases, of which 4.3% were symptomatic. There were no device-related complications. CONCLUSIONS: Initial postmarket results with the EmboTrap II stent retriever are favorable and comparable with those of other commercially available stent retrievers. Compared with EmboTrap II, the first-generation EmboTrap may have a higher first-pass efficacy; however, data are limited by retrospective case analysis, incomplete clinical follow-up, and small sample size, necessitating future trials.


Subject(s)
Ischemic Stroke/surgery , Stents , Thrombectomy/instrumentation , Treatment Outcome , Aged , Female , Humans , Male , Middle Aged , Product Surveillance, Postmarketing , Registries , Retrospective Studies , Thrombectomy/methods
4.
AJNR Am J Neuroradiol ; 42(2): 347-353, 2021 01.
Article in English | MEDLINE | ID: mdl-33361372

ABSTRACT

BACKGROUND AND PURPOSE: Visualization in neuroendovascular intervention currently relies on biplanar fluoroscopy and contrast administration. With the advent of endoscopy, direct visualization of the intracranial intravascular space has become possible with microangioscopes. We analyzed the efficacy of our novel microangioscope to enable direct observation and inspection of the cerebrovasculature, complementary to a standard fluoroscopic technique. MATERIALS AND METHODS: Iterations of microangioscopes were systematically evaluated for use in neurodiagnostics and neurointerventions in both live animal and human cadaveric models. Imaging quality, trackability, and navigability were assessed. Diagnostic procedures assessed included clot identification and differentiation, plaque identification, inspection for vessel wall injury, and assessment of stent apposition. Interventions performed included angioscope-assisted stent-retriever thrombectomy, clot aspiration, and coil embolization. RESULTS: The microangioscope was found helpful in both diagnosis and interventions by independent evaluators. Mean ratings of the imaging quality on a 5-point scale ranged from 3.0 (clot identification) to 4.7 (Pipeline follow-up). Mean ratings for clinical utility ranged from 3.0 (aspiration thrombectomy) to 4.7 (aneurysm treatment by coil embolization and WEB device). CONCLUSIONS: This fiber optic microangioscope can safely navigate and visualize the intravascular space in human cadaveric and in vivo animal models with satisfactory resolution. It has potential value in diagnostic and neurointerventional applications.


Subject(s)
Angioscopes , Angioscopy/instrumentation , Endovascular Procedures/instrumentation , Intracranial Aneurysm/surgery , Neuroendoscopy/instrumentation , Animals , Embolization, Therapeutic/instrumentation , Fluoroscopy/methods , Humans , Rabbits , Swine