Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
2.
Br J Radiol ; 86(1031): 20130388, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24049128

ABSTRACT

OBJECTIVE: To evaluate the image quality produced by six different iterative reconstruction (IR) algorithms in four CT systems in the setting of brain CT, using different radiation dose levels and iterative image optimisation levels. METHODS: An image quality phantom, supplied with a bone mimicking annulus, was examined using four CT systems from different vendors and four radiation dose levels. Acquisitions were reconstructed using conventional filtered back-projection (FBP), three levels of statistical IR and, when available, a model-based IR algorithm. The evaluated image quality parameters were CT numbers, uniformity, noise, noise-power spectra, low-contrast resolution and spatial resolution. RESULTS: Compared with FBP, noise reduction was achieved by all six IR algorithms at all radiation dose levels, with further improvement seen at higher IR levels. Noise-power spectra revealed changes in noise distribution relative to the FBP for most statistical IR algorithms, especially the two model-based IR algorithms. Compared with FBP, variable degrees of improvements were seen in both objective and subjective low-contrast resolutions for all IR algorithms. Spatial resolution was improved with both model-based IR algorithms and one of the statistical IR algorithms. CONCLUSION: The four statistical IR algorithms evaluated in the study all improved the general image quality compared with FBP, with improvement seen for most or all evaluated quality criteria. Further improvement was achieved with one of the model-based IR algorithms. ADVANCES IN KNOWLEDGE: The six evaluated IR algorithms all improve the image quality in brain CT but show different strengths and weaknesses.


Subject(s)
Algorithms , Brain/diagnostic imaging , Phantoms, Imaging , Radiation Dosage , Radiographic Image Enhancement/methods , Humans , Models, Theoretical , Neuroimaging , Radiation Protection/methods , Radiographic Image Enhancement/instrumentation , Tomography, X-Ray Computed/methods
3.
Radiat Prot Dosimetry ; 139(1-3): 287-92, 2010.
Article in English | MEDLINE | ID: mdl-20382975

ABSTRACT

The aim of this study was to evaluate the possibility of reducing the radiation dose to paediatric patients undergoing computed tomography (CT) brain examination by using image-enhancing software. Artificial noise was added to the raw data collected from 20 patients aged between 1 and 10 y to simulate tube current reductions of 20, 40 and 60 mA. All images were created in duplicate; one set of images remained unprocessed whereas the other was processed with image-enhancing software. Three paediatric radiologists assessed the image quality based on their ability to visualise the high- and low-contrast structures and their overall impression of the diagnostic value of the image. For patients aged 6-10 y, it was found that dose reductions from 27 mGy (CTDI(vol)) to 23 mGy (15 %) in the upper brain and from 32 to 28 mGy (13 %) in the lower brain were possible for standard diagnostic CT examinations when using the image-enhancing filter. For patients 1-5 y, the results for standard diagnostics in the upper brain were inconclusive, for the lower brain no dose reductions were found possible.


Subject(s)
Body Burden , Brain/diagnostic imaging , Radiation Dosage , Radiation Protection/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Child, Preschool , Female , Humans , Infant , Male , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
4.
Br J Radiol ; 83(991): 604-11, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20335429

ABSTRACT

The purpose was to demonstrate a non-parametric statistical method that can identify and explain the components of observer disagreement in terms of systematic disagreement as well as additional individual variability, in visual grading studies. As an example, the method was applied to a study where the effect of reduced tube current on diagnostic image quality in paediatric cerebral multidetector CT (MDCT) images was investigated. Quantum noise, representing dose reductions equivalent to steps of 20 mA, was artificially added to the raw data of 25 retrospectively selected paediatric cerebral MDCT examinations. Three radiologists, blindly and randomly, assessed the resulting images from two different levels of the brain with regard to the reproduction of high- and low-contrast structures and overall image quality. Images from three patients were assessed twice for the analysis of intra-observer disagreement. The intra-observer disagreement in test-retest assessments could mainly be explained by a systematic change towards lower image quality the second time the image was reviewed. The inter-observer comparisons showed that the paediatric radiologist was more critical of the overall image quality, while the neuroradiologists were more critical of the reproduction of the basal ganglia. Differences between the radiologists regarding the extent to which they used the whole classification scale were also found. The statistical method used was able to identify and separately measure a presence of bias apart from additional individual variability within and between the radiologists which is, at the time of writing, not attainable by any other statistical approach suitable for paired, ordinal data.


Subject(s)
Brain/diagnostic imaging , Tomography, X-Ray Computed/statistics & numerical data , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Neurology , Observer Variation , Pediatrics , Reproducibility of Results , Retrospective Studies , Statistics, Nonparametric , Tomography, X-Ray Computed/methods
5.
Br J Radiol ; 82(976): 313-20, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19188246

ABSTRACT

The aim of this study was to investigate the effect of tube current on diagnostic image quality in paediatric cerebral multidetector CT (MDCT) images in order to identify the minimum radiation dose required to reproduce acceptable levels of different diagnostic image qualities. Original digital scanning data (raw data) were selected retrospectively from routine MDCT brain examinations of 25 paediatric patients. All examinations had been performed using axial scanning on an eight-slice MDCT (LightSpeed Ultra, GE Healthcare). Their ages ranged from newborn to 15 years. Quantum noise was added artificially to the raw data representing dose reductions equivalent to steps of 20 mA. Patient identification information was removed. Three experienced radiologists blindly and randomly assessed the resulting images from two different levels of the brain with regard to reproduction of structures and overall image quality. Final data were evaluated using the non-parametric statistical approach of inter-scale concordance. The minimum value of tube current-time product (mAs) required to reproduce an image of sufficient diagnostic quality was established in relation to the age of the patient. The corresponding CT dose index values by volume (CTDI(vol) (mGy)) were also established. In conclusion, acceptable reproduction of low-contrast structures was possible at CTDI(vol) values down to 20 mGy (patients 1-5 years old). For acceptable reproduction of high-contrast structures, CTDI(vol) values down to 10 mGy were considered possible (patients 1-5 years old). The original image quality for patients under 6 months of age (15 mGy) was found to be inadequate for acceptable reproduction of low-contrast structures.


Subject(s)
Brain/diagnostic imaging , Neoplasms, Radiation-Induced/prevention & control , Tomography, X-Ray Computed/adverse effects , Adolescent , Age Factors , Child , Child, Preschool , Clinical Protocols , Dose-Response Relationship, Radiation , Female , Humans , Infant , Male , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Reference Values , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed/instrumentation
6.
Radiat Prot Dosimetry ; 114(1-3): 313-6, 2005.
Article in English | MEDLINE | ID: mdl-15933128

ABSTRACT

The purpose of this study was to develop an equation with which to determine the tube current to be used in order to obtain a certain image noise level for differently sized children undergoing multi-slice computed tomography examination. The relationship between image noise and detector dose for different examination protocols was established for a LightSpeed Ultra, an eight slice CT from GEMS, using homogeneous water phantoms of different sizes. Three different anatomical areas (head, thorax and abdomen) were studied in 111 patients between 0 and 17 y of age. The mean ratio between the calculated and the measured noise in patient images was established for the different areas. Head examinations showed the best correlation (measured-to-calculated noise ratio = 1.01). In the thorax, the calculated noise was generally higher than the measured noise (ratio = 0.74), and in the abdomen, the opposite result was found (ratio = 1.20).


Subject(s)
Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods , Artifacts , Head/diagnostic imaging , Humans , Phantoms, Imaging , Radiation Dosage , Radiographic Image Enhancement , Radiography, Abdominal/methods , Radiography, Thoracic/methods , Tomography Scanners, X-Ray Computed , Water/chemistry
7.
Acta Paediatr ; 92(8): 980-2, 2003 Aug.
Article in English | MEDLINE | ID: mdl-12948078

ABSTRACT

UNLABELLED: Scedosporium prolificans is an environmental mould that may cause local infection in bone and joints after traumatic implantation, or generalized infection in immunocompromised patients. The fungus is highly drug resistant, both in vitro and in vivo. We present a case of osteomyelitis and arthritis caused by S. prolificans in a 9-y-old boy whose knee had been punctured by a hawthorn spike. Treatment with different drugs was difficult and arthrodesis was necessary. Concomitantly, voriconazole was given, and after three months bone biopsies were sterile despite a high in vitro MIC-value of the fungus against voriconazole. Reversible skin depigmentation and fingernail oncholysis appeared toward the end of 17 months of voriconazole treatment. Twelve months after discontinuation of treatment, no signs of relapse were detected. CONCLUSION: Voriconazole may be a valuable adjunct to surgical treatment of bone and joint infection by Scedosporium prolificans.


Subject(s)
Arthritis, Infectious/etiology , Bone Diseases, Infectious/etiology , Knee Injuries/complications , Mycetoma/etiology , Scedosporium , Wounds, Penetrating/complications , Arthritis, Infectious/diagnosis , Arthritis, Infectious/drug therapy , Arthritis, Infectious/surgery , Bone Diseases, Infectious/diagnosis , Bone Diseases, Infectious/drug therapy , Bone Diseases, Infectious/surgery , Child , Crataegus , Humans , Knee Injuries/diagnostic imaging , Knee Injuries/microbiology , Knee Injuries/surgery , Male , Radiography , Wounds, Penetrating/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...