Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Sci Rep ; 8(1): 4707, 2018 03 16.
Article in English | MEDLINE | ID: mdl-29549305

ABSTRACT

Arthroplasty registers were originally established in Scandinavia to receive clinically relevant information from pooled data, to improve quality and reduce revision surgeries, with socioeconomic benefit. In Austria, where the highest rate of total knee arthroplasties (TKA) per inhabitant of all OECD countries was reached in 2014, arthroplasties are centrally reported since 2009. Study purpose was to perform the first analysis of the Austrian database, aiming to obtain data on trends in arthroplasty in Austria over time in relation to demographic development. Between 2009 and 2015 an almost continuous increase of total hip arthroplasties (THA; 18.052) by 14% and TKA (17.324) by 13% were observed, representing 210 THA and 202 TKA per 100k inhabitants in 2015. A similar increase was found for revision surgeries, with 1.290 re-implanted THA (7.1% of all THA) and 919 re-implanted TKA (5.3% of all TKA) in 2015. Implantation of mega or tumor prosthesis for the knee and hip joint remained constant and was mainly performed in two university hospitals. Patellar resurfacing decreased by 31.6%. Demographic development will further increase the number of primary and revision surgeries. Inclusion of more detailed information on used and revised components was established and will improve efficacy in quality control.


Subject(s)
Arthroplasty, Replacement, Hip/economics , Arthroplasty, Replacement, Hip/trends , Arthroplasty, Replacement, Knee/economics , Arthroplasty, Replacement, Knee/trends , Databases, Factual , Reoperation/economics , Reoperation/trends , Aged , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Knee/instrumentation , Austria , Female , Humans , Male
2.
Acta Orthop ; 82(2): 131-5, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21434760

ABSTRACT

BACKGROUND AND PURPOSE: The reproducibility of results and potential confounders in sample-based studies is important to consider in the assessment of studies. Comprehensive arthroplasty registers could serve as a reference dataset for comparative analyses. We analyzed an implant that is frequently used worldwide, the Oxford unicompartmental knee replacement, in order to identify potential confounders inherent in the datasets and to evaluate the outcome achieved with this implant. METHODS: We performed a structured literature review of the data published on the revision rate of the Oxford medial unicompartmental arthroplasty. Both clinical follow-up studies and worldwide registry data were included. Confidence intervals were calculated to determine the statistical significance of differences. RESULTS: A substantial proportion of the published data (52-68% depending on the method of calculation) is derived from studies involving participation of the institution that developed the implant. The results published by this group show a statistically significant deviation from the reference datasets from registers or independent studies. Data from the developing hospital show mean revision rates that are 4 times lower than those based on worldwide register data, and 3 times lower than the ones quoted in independent studies. On average, the data published in independent studies are reproducible in registry data. INTERPRETATION: A conventional meta-analysis of clinical studies is substantially affected by the influence of the developing hospital, and is therefore subject to bias. For assessment of the outcome of implants, registry data are superior and, in terms of reference data for the detection of potential bias factors in the literature, could make an essential contribution to meta-analyses.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Follow-Up Studies , Humans , Knee Prosthesis , Minimally Invasive Surgical Procedures/methods , Outcome Assessment, Health Care , Prosthesis Design , Registries , Treatment Outcome
3.
Eur Spine J ; 14(9): 906-9, 2005 Nov.
Article in English | MEDLINE | ID: mdl-15937672

ABSTRACT

The authors report two cases of delayed post-operative anterior spinal artery syndrome (ASAS) following posterior correction with Cotrel Dubousset (CD) instrumentation for adolescent idiopathic scoliosis. Sensory pathways were continuously monitored from skin incision to awakening. In both cases intraoperative SEPs were normal and the wake-up test revealed no neurological deficit. Both patients were presented with incomplete paraplegia (no sensory impairment) three and ten hours after surgery. Without delay, both patients underwent revision surgery, and the CD instrumentation was removed. Immediately after surgery, both patients' motor power in their lower extremities improved rapidly. In cases with delayed ASAS after posterior scoliosis correction, the removal of the instrumentation system was shown to be sufficient to regain full motor recovery caudal to the level of impairment.


Subject(s)
Anterior Spinal Artery Syndrome/etiology , Spinal Fusion/adverse effects , Adolescent , Anterior Spinal Artery Syndrome/surgery , Device Removal , Female , Humans , Magnetic Resonance Imaging , Male , Paraplegia/etiology , Paraplegia/surgery , Spinal Fusion/instrumentation , Time Factors
4.
Clin Orthop Relat Res ; (426): 180-6, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15346071

ABSTRACT

Successful total knee arthroplasty is dependent on the correct alignment of implanted prostheses. Major clinical problems can be related to poor femoral component positioning, including sagittal plane and rotational malalignment. A prospective randomized study was designed to test whether an optical navigation system for total knee arthroplasty achieved greater implantation precision than a nonnavigated technique. The primary variable was rotation of the femoral component in the transverse plane, measured from postoperative radiographs and computed tomography images. Sixty-four patients were included in the study. All patients received the Duracon total knee prosthesis. The patients were randomly divided into two groups: Group C patients had conventional total knee arthroplasty without navigation; Group N patients had total knee arthroplasty using a computer-assisted knee navigation system. Analysis showed that patients in Group N had significantly better rotational alignment and flexion angle of the femoral component than patients in Group C. In addition, superior postoperative alignment of the mechanical axis, posterior tibial slope, and rotational alignment was achieved for patients in Group N. The use of a navigation system provides improved alignment accuracy, and can help to avoid femoral malrotation and errors in axial alignment.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Surgery, Computer-Assisted , Aged , Aged, 80 and over , Female , Humans , Knee Joint/diagnostic imaging , Knee Prosthesis , Male , Middle Aged , Radiography
5.
Clin Orthop Relat Res ; (398): 196-202, 2002 May.
Article in English | MEDLINE | ID: mdl-11964651

ABSTRACT

The abnormal bony feature found most consistently in clubfeet is talar distortion. The significance of the talar distortion for mobility of the tibiotalar joint was investigated. Twenty-seven congenital clubfeet in 19 patients were examined at a minimal followup of 20 years. In all patients Turco's posteromedial release was done because of idiopathic clubfoot. Radiographic assessment of the feet included measurement of the talocalcaneal angle and index, and the tibiocalcaneal angle. The degree of talar flattening was estimated by the ratio of the curvature of the talar dome to the length of the talar bone (radius to length ratio). Three-dimensional gait analysis was done to assess the dynamic range of ankle motion. The static range of motion was measured with a goniometer. The degree of talar flattening correlated significantly with the dynamic range of ankle motion but not with the static mobility. For assessment of idiopathic clubfoot, evaluation of talar flattening should be done because of its significance for dynamic ankle mobility.


Subject(s)
Ankle Joint/physiopathology , Clubfoot/physiopathology , Talus/abnormalities , Adult , Analysis of Variance , Clubfoot/diagnostic imaging , Clubfoot/surgery , Female , Follow-Up Studies , Humans , Male , Radiography , Range of Motion, Articular , Regression Analysis , Talus/diagnostic imaging , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...