Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Ultrasound Med Biol ; 50(6): 797-804, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38485534

ABSTRACT

OBJECTIVE: Evaluation of left ventricular (LV) function in critical care patients is useful for guidance of therapy and early detection of LV dysfunction, but the tools currently available are too time-consuming. To resolve this issue, we previously proposed a method for the continuous and automatic quantification of global LV function in critical care patients based on the detection and tracking of anatomical landmarks on transesophageal heart ultrasound. In the present study, our aim was to improve the performance of mitral annulus detection in transesophageal echocardiography (TEE). METHODS: We investigated several state-of-the-art networks for both the detection and tracking of the mitral annulus in TEE. We integrated the networks into a pipeline for automatic assessment of LV function through estimation of the mitral annular plane systolic excursion (MAPSE), called autoMAPSE. TEE recordings from a total of 245 patients were collected from St. Olav's University Hospital and used to train and test the respective networks. We evaluated the agreement between autoMAPSE estimates and manual references annotated by expert echocardiographers in 30 Echolab patients and 50 critical care patients. Furthermore, we proposed a prototype of autoMAPSE for clinical integration and tested it in critical care patients in the intensive care unit. RESULTS: Compared with manual references, we achieved a mean difference of 0.8 (95% limits of agreement: -2.9 to 4.7) mm in Echolab patients, with a feasibility of 85.7%. In critical care patients, we reached a mean difference of 0.6 (95% limits of agreement: -2.3 to 3.5) mm and a feasibility of 88.1%. The clinical prototype of autoMAPSE achieved real-time performance. CONCLUSION: Automatic quantification of LV function had high feasibility in clinical settings. The agreement with manual references was comparable to inter-observer variability of clinical experts.


Subject(s)
Anatomic Landmarks , Echocardiography, Transesophageal , Ventricular Function, Left , Humans , Echocardiography, Transesophageal/methods , Ventricular Function, Left/physiology , Anatomic Landmarks/diagnostic imaging , Female , Male , Aged , Middle Aged , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Image Interpretation, Computer-Assisted/methods
2.
JACC Cardiovasc Imaging ; 16(12): 1516-1531, 2023 12.
Article in English | MEDLINE | ID: mdl-37921718

ABSTRACT

BACKGROUND: Myocardial deformation by echocardiographic strain imaging is a key measurement in cardiology, providing valuable diagnostic and prognostic information. Reference ranges for strain should be established from large healthy populations with minimal methodologic biases and variability. OBJECTIVES: The aim of this study was to establish echocardiographic reference ranges, including lower normal limits of global strains for all 4 cardiac chambers, by guideline-directed dedicated views from a large healthy population and to evaluate the influence of subject-specific characteristics on strain. METHODS: In total, 1,329 healthy participants from HUNT4Echo, the echocardiographic substudy of the 4th wave of the Trøndelag Health Study, were included. Echocardiographic recordings specific for each chamber were optimized according to current recommendations. Two experienced sonographers recorded all echocardiograms using GE HealthCare Vivid E95 scanners. Analyses were performed by experts using GE HealthCare EchoPAC. RESULTS: The reference ranges for left ventricular (LV) global longitudinal strain and right ventricular free-wall strain were -24% to -16% and -35% to -17%, respectively. Correspondingly, left atrial (LA) and right atrial (RA) reservoir strains were 17% to 49% and 17% to 59%. All strains showed lower absolute values with higher age, except for LA and RA contractile strains, which were higher. The feasibility for strain was overall good (LV 96%, right ventricular 83%, LA 94%, and RA 87%). All chamber-specific strains were associated with age, and LV strain was associated with sex. CONCLUSIONS: Reference ranges of strain for all cardiac chambers were established based on guideline-directed chamber-specific recordings. Age and sex were the most important factors influencing reference ranges and should be considered when using strain echocardiography.


Subject(s)
Echocardiography , Global Longitudinal Strain , Humans , Reference Values , Predictive Value of Tests , Echocardiography/methods , Heart Atria/diagnostic imaging , Ventricular Function, Left
3.
Artif Intell Med ; 144: 102646, 2023 10.
Article in English | MEDLINE | ID: mdl-37783546

ABSTRACT

Perioperative monitoring of cardiac function is beneficial for early detection of cardiovascular complications. The standard of care for cardiac monitoring performed by trained cardiologists and anesthesiologists involves a manual and qualitative evaluation of ultrasound imaging, which is a time-demanding and resource-intensive process with intraobserver- and interobserver variability. In practice, such measures can only be performed a limited number of times during the intervention. To overcome these difficulties, this study presents a robust method for automatic and quantitative monitoring of cardiac function based on 3D transesophageal echocardiography (TEE) B-mode ultrasound recordings of the left ventricle (LV). Such an assessment obtains consistent measurements and can produce a near real-time evaluation of ultrasound imagery. Hence, the presented method is time-saving and results in increased accessibility. The mitral annular plane systolic excursion (MAPSE), characterizing global LV function, is estimated by landmark detection and cardiac view classification of two-dimensional images extracted along the long-axis of the ultrasound volume. MAPSE estimation directly from 3D TEE recordings is beneficial since it removes the need for manual acquisition of cardiac views, hence decreasing the need for interference by physicians. Two convolutional neural networks (CNNs) were trained and tested on acquired ultrasound data of 107 patients, and MAPSE estimates were compared to clinically obtained references in a blinded study including 31 patients. The proposed method for automatic MAPSE estimation had low bias and low variability in comparison to clinical reference measures. The method accomplished a mean difference for MAPSE estimates of (-0.16±1.06) mm. Thus, the results did not show significant systematic errors. The obtained bias and variance of the method were comparable to inter-observer variability of clinically obtained MAPSE measures on 2D TTE echocardiography. The novel pipeline proposed in this study has the potential to enhance cardiac monitoring in perioperative- and intensive care settings.


Subject(s)
Artificial Intelligence , Mitral Valve , Humans , Mitral Valve/diagnostic imaging , Ultrasonography , Echocardiography/methods , Ventricular Function, Left
4.
Ultrasound Med Biol ; 49(1): 333-346, 2023 01.
Article in English | MEDLINE | ID: mdl-36280443

ABSTRACT

Measurements of cardiac function such as left ventricular ejection fraction and myocardial strain are typically based on 2-D ultrasound imaging. The reliability of these measurements depends on the correct pose of the transducer such that the 2-D imaging plane properly aligns with the heart for standard measurement views and is thus dependent on the operator's skills. We propose a deep learning tool that suggests transducer movements to help users navigate toward the required standard views while scanning. The tool can simplify echocardiography for less experienced users and improve image standardization for more experienced users. Training data were generated by slicing 3-D ultrasound volumes, which permits simulation of the movements of a 2-D transducer. Neural networks were further trained to calculate the transducer position in a regression fashion. The method was validated and tested on 2-D images from several data sets representative of a prospective clinical setting. The method proposed the adequate transducer movement 75% of the time when averaging over all degrees of freedom and 95% of the time when considering transducer rotation solely. Real-time application examples illustrate the direct relation between the transducer movements, the ultrasound image and the provided feedback.


Subject(s)
Echocardiography, Three-Dimensional , Ventricular Function, Left , Stroke Volume , Reproducibility of Results , Prospective Studies , Echocardiography/methods
5.
J Anal Toxicol ; 45(7): e1-e3, 2021 Aug 14.
Article in English | MEDLINE | ID: mdl-33031536

ABSTRACT

A young man with an unremarkable medical history suffered a seizure with subsequent cardiorespiratory arrest and severe neurological sequelae after ingesting a blotter. Analysis of a similar blotter and a serum sample obtained 3 h after the event detected lysergic acid diethylamide (LSD) at an amount of 300 µg in the blotter and at a concentration of 4.0 ng/mL (12.4 nmol/L) in the serum. No other drugs were present in concentrations which may confer significant effects. In addition, no individual traits which would make the patient particularly susceptible to adverse LSD effects have subsequently been identified. This suggests that LSD may confer toxic effects in previously healthy individuals.


Subject(s)
Hallucinogens , Lysergic Acid Diethylamide , Hallucinogens/toxicity , Humans , Lysergic Acid Diethylamide/toxicity , Male
6.
J Ultrasound Med ; 39(12): 2313-2323, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32436616

ABSTRACT

OBJECTIVES: To study the feasibility and accuracy of focused echocardiography by nurses supported by near-real-time interpretation via telemedicine by an experienced cardiologist. METHODS: Fifty consecutive patients were included from an outpatient heart failure (HF) clinic. Limited echocardiography was performed by 1 of 3 specialized nurses. The echocardiograms were transferred by a secure transfer model for near-real-time interpretation to 1 out-of-hospital cardiologist, assessing, among others, the left ventricular (LV) internal diameter, end-diastolic volume, ejection fraction, left atrial (LA) indexed end-systolic volume, mitral early inflow velocity (E), the ratio of E to mitral late inflow, and the ratio of E to the mitral annular early diastolic velocity. The reference method was echocardiography by 1 of 4 experienced cardiologists. RESULTS: The median age of the population (46% women) was 79 (range, 33-95) years. The assessment and quantification of LA and LV dimensions, volumes, and functional indices were feasible in 94% or more via the telemedical approach. The agreement with reference measurements was very high by the telemedical approach. The mean duration ± SD of the complete telemedical approach from the start of echocardiography until the cardiologist's report was received by the caregiving nurse was 1.32 ± 0.36 (range, 1.58) hours. The correlations with reference to the above-specified indices were r = 0.75 to 0.94. CONCLUSIONS: Limited echocardiography by nurses in an outpatient heart failure clinic, supported by interpretation by an out-of-hospital cardiologist, was feasible and reliable. This may reduce geographic disparities and allow more patients to benefit from the advantages of implementing focused echocardiography by noncardiologists in diagnostics and follow-up.


Subject(s)
Heart Failure , Telemedicine , Ventricular Dysfunction, Left , Adult , Aged , Aged, 80 and over , Echocardiography , Feasibility Studies , Female , Heart Failure/diagnostic imaging , Humans , Male , Middle Aged , Outpatients , Stroke Volume , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...